Validation of Non-invasive Absolute Intracranial Pressure Monitoring

Open Study on the Validation of Non-invasive Absolute Intracranial Pressure Monitoring in Patients After Traumatic Brain Injury and Subarachnoid Hemorrhage

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03227354
Enrollment
25
Registered
2017-07-24
Start date
2017-09-30
Completion date
2019-09-30
Last updated
2017-07-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Pressure Increase, Traumatic Brain Injury

Keywords

Medical Device

Brief summary

Primary objective of this study is to assess the accuracy and precision of intracranial pressure (ICP) measurement in patients after traumatic brain injury and subarachnoid hemorrhage when using simultaneous, non-invasive measurement compared to standard, invasive, measurement. Secondary objective: is to assess the correlation of intracranial pressure (ICP) measurement in patients after traumatic brain injury and subarachnoid hemorrhage between simultaneous, non-invasive measurement and standard, invasive,measurement

Detailed description

Currently, ICP (Intracranial Pressure) can be measured only using invasive techniques. In a previous (pilot study) a non-invasive technique for measurement of ICP was investigated (based on simultaneously measuring of ophthalmic artery (OA) blood flow parameters in the intracranial (IOA) and extracranial (EOA) segments of the OA with two-depth transcranial Doppler (TCD)). Based on the good results of the previous study, the study should be repeated in order to further validate the new method in more patients and to obtain additional insight with more measurements. This single centre, observational comparative study shall investigate a new non-invasive ICP absolute value measurement method in patients presenting with TBI, ICH, or secondary edema after stroke or Subarachnoid Hemorrhage (SAH) compared to current standard invasive ICP monitoring methods.Suitable patients are to be recruited soonest after their referral or admission to the Department of Neurosurgery at the Kantonsspital Aarau. Measurement will be done either at the surgical Intensive Care Unit, Stroke Unit (SIC) or Neurosurgical Intermediate Care Unit (NCW). All measurements will be performed on intubated and sedated patients with invasive ICP Monitoring trough an intraparenchymatous or intraventricular probe. In the same patient, several measurements will be allowed daily. The non-invasive technique for measurement of ICP is based on simultaneously measuring of an ophthalmic artery (OA) blood flow parameters in the intracranial (IOA) and extracranial (EOA) segments of the OA with two-depth transorbital Doppler (TCD) measurements including mechanical head frame for fixation of ultrasonic transducer on the closed eye lid. ICP pressure will be measured non-invasively by using Vittamed 205® device. This device has CE marking since July 2014. It is planned to recruit 25 patients and to collect 69 independent paired non-invasive and invasive ICP measurements during a 24 months period after study approval.

Interventions

DEVICEVittamed 205

non-invasive Intracranial Pressure measurement

Sponsors

Swiss National Science Foundation
CollaboratorOTHER
Kienzler Jenny
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients, age ≥ 18 years, admitted after TBI, ICH, secondary edema after stroke or SAH at the Departments of Neurosurgery or Neurology, Kantonsspital Aarau, Switzerland. * Patients under sedation and ICP monitoring * Informed consent obtained from the legally authorized representative prior initiation of the measurements.

Exclusion criteria

Age \< 18 years at study entry. * Patients with wounds, scars including the front orbital region. * Perforating or penetrating mechanism of TBI * Patients with orbital injury or abnormal blood flow in both Ophthalmic Arteries * Patients with previous retina surgery * Patients with previous cataract surgery * Patients with any known ocular condition that may be worsened by sustained eye pressure in the opinion of the subject's ophthalmologist * Patients with radiological signs of calcification or atheromatose plaques in the internal carotid artery detected by CT or angiography (performed prior and independently of the study)

Design outcomes

Primary

MeasureTime frameDescription
Absolute intracranial pressure35 minutes per measurementabsolute intracranial ICP, measured simultaneously with the non-invasive and the standard invasive method

Other

MeasureTime frameDescription
Safety outcomeduring measurementsIncidence of device related Adverse Events and Serious Adverse Events