Skip to content

Sterilizing Effects of the Erbium:YAG Laser Upon Metal Implants

Sterilizing Effects of the Erbium:YAG Laser Upon Metal Implants

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03226184
Enrollment
50
Registered
2017-07-21
Start date
2012-07-01
Completion date
2017-10-01
Last updated
2017-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Orthopedic Devices Associated With Misadventures, Prosthetic and Other Implants, Materials and Accessory Devices

Keywords

Er:YAG laser, laser, biofilm removal, biofilm, disinfection, septic revision surgery

Brief summary

Background: Even today, postoperative infection is the commonest complications after surgery although all aseptic precautions are taken and causes significant postoperative morbidity, mortality, prolongs hospital stay, and increases costs. Infections that are related to orthopaedic procedures are considered particularly severe when implantation materials are used which further increases the risk of infection and holds the risk of biofilm formation. This is of particular concern since biofilm-mediated infections are difficult to diagnose and effective treatments are lacking. Therefore, new strategies for implant infection are currently being researched worldwide. In this study the relatively new approach for infection control by using an Er:YAG laser was adapted to an orthopaedic and traumatologic setting. This laser vaporizes all water containing cells in a very effective, precise and predictable manner and shows only a minimal thermal damage. Methods: For preliminary testing 42 steel pins and 42 plates were cultivated with cocultures for 2 weeks. The minimally necessary laser energy for biofilm removal was determined. We subsequently compared the effectiveness of biofilm removal with the Er:YAG laser and a cleansing of the metal implants with Octenidine soaked gauze. The temperature rise within the metal during the laser procedure was also measured. In order to achieve an approximation to a clinical setting we want to compared the same effectiveness of biofilm removal similarly on steel pins directly after explantation from patients treated with external fixators for at least 2 weeks. Sonication and SEM will be used for analysis. Preliminary Results Laser fluences exceeding 2.8J/cm2 caused a complete extinction of all living cells by a single laser impulse. Temperature rise within the implant is dependent on repetition frequency but overall negligible. The effectiveness of biofilm removal after cleansing with Octenidine soaked gauze and irradiation with the Er:YAG laser will be evaluated on cultivated and extracted pins. Conclusions We want to compare the effectiveness of the Er:YAG laser and Octenidine in the removal of biofilms from half-pins. We hypothesize that thee Er:YAG laser offers a secure, complete and non toxic removal of all kinds of pathogens from steel implants without damaging the implant or possible development of resistances. The precise non-contact removal of adjacent tissue could be an advantage over other disinfectants. Level of Evidence (II-a) Clinical Relevance: Having one more arrow in the quiver for disinfection of percutaneous implants or for septic revision surgery when osteosynthesis equipment or arthroplasties are meant to be left in place would be extremely desirable.

Interventions

None listed

Sponsors

Paracelsus Medical University
CollaboratorOTHER
Medical University of Vienna
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL

Inclusion criteria

All patients that are treated with external fixators for at least 2 weeks and patients whose implants have to be removed during septic revision surgery.

Exclusion criteria

\-

Design outcomes

Primary

MeasureTime frameDescription
Completeness of biofilm removal2 yearsIs the Er:YAG laser able to remova a microbial biofilm from cultivated or infected implants

Secondary

MeasureTime frameDescription
Side effects2 yearsAre there side effect to be expected from laser Irradiation either for the implant or for the surrounding tissue in a possible clinical setting

Countries

Austria

Contacts

Primary ContactLukas K Kriechbaumer, MD
lukikriechbaumer@hotmail.com+43 (0) 5 7255 - 57156
Backup ContactSylvia Nürnberger, MSc
sylvia.nuernberger@meduniwien.ac.at+43 1 40400 59440

Outcome results

None listed