Skip to content

RNFL Thickness Measurements Obtained Using SD-OCT and SLP Using GDx Variable Corneal Compensation

Correlation in Retinal Nerve Fiber Layer Thickness in Uveitis and Healthy Eyes Using Scanning Laser Polarimetry and Optical Coherence Tomography

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03206268
Acronym
Real
Enrollment
54
Registered
2017-07-02
Start date
2015-05-01
Completion date
2015-10-31
Last updated
2018-05-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Uveitis

Keywords

retinal nerve fiber layer thickness, uveitis, SD-OCT, GDx VCC

Brief summary

The aim of this study is to evaluate the correlation of retinal nerve fiber layer (RNFL) thickness measured using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP) in uveitic eyes compared to healthy eyes. A descriptive, observational, prospective, consecutive, cross-sectional, controlled, mono-center case series was conducted from May to October 2015. Clinical characteristics, best-corrected visual acuity, intra-ocular pressure, RNFL thickness measurement with SD-OCT and SLP using GDx variable corneal compensation (GDx VCC) were performed for each patient. An evaluation of anterior chamber inflammation with laser flare cell meter was also carried out. Correlations between SD-OCT and GDx VCC RNFL measurement were evaluated by linear regression analysis.

Interventions

DEVICESD-OCT and SLP using GDx variable corneal compensation

RNFL thickness measurements obtained using SD-OCT and SLP using GDx variable corneal compensation

Sponsors

Hospices Civils de Lyon
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* age ≥18 years, * best-corrected visual acuity better than or equal to 20/40, * spherical refraction between -6.00 and +3.00 diopters, * no retinal disease or non-glaucomatous neuropathy, and no ophthalmic surgery in the past 6 months.

Exclusion criteria

* Healthy eye were excluded in case of consecutive and reliable abnormal standard automated perimetry with abnormal Glaucoma Hemifield Test and pattern standard deviation outside 95% of normal limits, and optic nerve damage (asymmetric cup-to-disc ratio ≥ 0.2, rim thinning, notching, excavation, or retinal nerve fiber layer defect). * any history of ophthalmic disease.

Design outcomes

Primary

MeasureTime frameDescription
Retinal nerve fiber thickness (RNFL)at inclusionmeasures are made with spectral domain optical coherence tomography (SD-OCT) in micrometer

Countries

France

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026