Clinical Performance of BioCLIA Ro60

Evaluation of Clinical Performance of Serologic Anti-Ro60 Autoantibody Detection Kit on BioCLIA Platform

Status
Withdrawn
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03204448
Enrollment
0
Registered
2017-07-02
Start date
2017-05-08
Completion date
2020-04-16
Last updated
2020-08-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sjogren's Syndrome, Systemic Lupus Erythematosus

Brief summary

The study is to evaluate the clinical performance of BioCLIA Ro60 for measuring the autoantibody in autoimmune disease patients.

Detailed description

100-200 clinically-diagnosed disease samples, as well as approximately 300 samples of various control diseases, will be used in the study. The specimen will be collected as the clinically leftover samples that have been used for routine clinical diagnosis purpose or research purpose, and with de-identification methods. Each set of samples will also be tested on a control serologic Anti-Ro60 detection kit, QUANTA Flash Ro60. Clinical sensitivity and clinical specificity will be analyzed for, also a method comparison conclusion will be drawn by comparing the two methods.

Interventions

DEVICEBioCLIA Ro60

BioCLIA Ro60 is a Chemiluminescent Immuno Assay (CLIA) as a fully automated testing process, reporting with arbitrary units, RU/mL

Sponsors

HOB Biotech Group
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosed with relevant diseases, including Systemic lupus erythematosus (SLE) and Sjogren's syndrome (SS) * Or diagnosed with other control diseases, including Rheumatoid arthritis (RA), Infectious diseases and others

Exclusion criteria

* Treatment with medicine that submerge the autoantibody concentration to non-detectable range * Co-diagnosed with multiple relevant diseases (e.g., SLE / SS) and/or control diseases * Hemolyzed sample.

Design outcomes

Primary

MeasureTime frameDescription
Clinical performance of BioCLIA Ro6010 monthsAbout 500 μl or more of each de-identified sample, in the form of serum or plasma, will be tested on-board with the automated BioCLIA serologic antinuclear antibodies (ANA) assay. Result will be reported in the form or IU/ml of antibodies in the samples. Clinical sensitivity of BioCLIA Ro60 will be determined by dividing the number of Ro60 positives by the number of relevant disease samples. Clinical specificity of BioCLIA will be determined by dividing the number of Ro60 negatives by the number of control disease samples.

Secondary

MeasureTime frameDescription
Method comparison between BioCLIA Ro60 and BioFlash/QUANTA Flash Ro602 monthsThe same samples tested in BioCLIA Ro60 will be tested on-board with the automated BioFLASH instrument with QUANTA Flash Ro60 reagents. Result will be reported in the form of CU of antibodies in the samples. Clinical sensitivity of BioFLASH/QUANTA Flash Ro60 will be determined by dividing the number of Ro60 positives by the number of relevant disease samples. Clinical specificity of BioFLASH/QUANTA Flash Ro60 will be determined by dividing the number of Ro60 negatives by the number of control disease samples. Degree of agreement between BioCLIA Ro60 and BioFLASH/QUANTA Flash Ro60 will be calculated.

Countries

United States

Outcome results

None listed