Skip to content

Wearable Technology in Shoulder Range of Motion

Wearable Technology in Shoulder Range of Motion: Validation of a Motion-Based Software Development Kit

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03195751
Enrollment
10
Registered
2017-06-22
Start date
2017-09-13
Completion date
2017-09-23
Last updated
2017-10-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Normal Upper Extremity

Keywords

telemonitoring

Brief summary

The scope of the research is to determine if a motion-based software development kit may substitute for a manual goniometer. If so, this opens up the possibility of remote telemonitoring of upper extremities patients.

Detailed description

The Capture mobile application or app (FocusMotion, Santa Monica, California) was custom designed and securely installed on a single (CCF) smartphone used by the Lead Co-Investigator, Dr. Ramkumar, and serves as a private user interface for the proprietary software development kit (SDK). The Capture app uses a Bluetooth connection to pair with the Pebble Time Round smartwatch to allow for remote timekeeping of the smartphone while in use by the participant. The smartwatch was loaned by FocusMotion to the investigators for the purpose of the study. This proprietary SDK (FocusMotion) processes user motions recorded by the hardware (accelerometer, gyroscope, magnometer). As data is collected, the software development kit (SDK) classifies the motion as repetitive or non-repetitive, and repetitive motions are further analyzed. As the user completes a workout or movement, the SDK tracks the number of repetitions performed, technique, and rest time. The SDK can provide real-time feedback to the user regarding their form by comparing the movement to a template of an ideal motion for that particular action. The SDK is compatible with any operating system, phone, or wearable device, providing seamless integration with pre-existing technologies. Measurements from the SDK will be compared to those taken with a manual goniometer for four shoulder maneuvers (abduction, forward flexion, internal rotation, external rotation). Each of the 10 subjects will perform 5 trials of each maneuver for consistency and reproducibility. Participants without shoulder pain, with full shoulder range of motion and without prior shoulder surgery will be recruited. No other exclusion criteria will be instituted. Individuals will be recruited from CCF undergraduate and graduate medical education programs. Statistical analysis will be employed to assess the shoulder motion arcs measured from both the SDK and the manual goniometer. Univariate analyses (chi-square for categorical and t-test for continuous variables) will be performed to compare the angle measurements from each patient and angle measurement. Power analysis indicated a 94% chance of detecting a large effect size and a 60% chance of detecting a medium effect size between the two groups at the 5% confidence level. For 1 sample t-tests, power analysis indicated that there was a 92% chance of detecting a medium effect size significant at the 5% confidence level. All data analysis will be performed using Microsoft. Excel analytics software version 14.5.4 A p-value cutoff of \<0.05 was used to determine statistical significance. All adverse events will be reported to the Institutional Review Board.

Interventions

DEVICESoftware development kit measurements

This proprietary SDK (FocusMotion) processes user motions recorded by the hardware (accelerometer, gyroscope, magnometer). As data is collected, the software development kit (SDK) classifies the motion as repetitive or non-repetitive, and repetitive motions are further analyzed. As the user completes a movement, the SDK tracks the number of repetitions performed, technique, and rest time. The SDK can provide real-time feedback to the user regarding their form by comparing the movement to a template of an ideal motion for that particular action. The SDK is compatible with any operating system, phone, or wearable device, providing seamless integration with pre-existing technologies.

DEVICEManual Goniometer Measurements

A manual goniometer was used to measure the range of motion of the shoulder.

Sponsors

The Cleveland Clinic
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 40 Years
Healthy volunteers
Yes

Inclusion criteria

* No prior shoulder pain * No prior shoulder surgeries * No limitations in shoulder range of motion

Exclusion criteria

* Prior shoulder surgeries * Past or present shoulder pain * Any limitations in shoulder range of motion

Design outcomes

Primary

MeasureTime frameDescription
Difference in range of motion measurements between goniometer and software development kit measurement24 hoursThe outcome measure difference will be in degrees.

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026