Skip to content

Detection of Deterioration by SNAP40 Versus Standard Monitoring in the ED

Detection of Physiological Deterioration by the SNAP40 Wearable Device Compared to Standard Monitoring Devices in the Emergency Department

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03179267
Acronym
SNAP40ED
Enrollment
250
Registered
2017-06-07
Start date
2017-09-25
Completion date
2017-12-22
Last updated
2018-04-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vital Signs

Keywords

vital signs, monitoring, early warning score

Brief summary

In recent years there has been increasing focus on the earlier detection of deterioration in the clinical condition of hospital patients with the aim of instigating earlier treatment to reverse this deterioration and prevent adverse outcomes. This is especially important in the ED, a dynamic environment with large volumes of undifferentiated patients, which carries inherent patient risk. SNAP40 is an innovative medical-grade device that can be worn on the upper arm that continuously monitors patients' vital signs including relative changes in systolic blood pressure, respiratory rate, heart rate, movement, blood oxygen saturation and temperature. It uses automated risk analysis to potentially allow clinical staff to easily and quickly identify high-risk patients. The aim of this study is to investigate whether the SNAP40 device is able to identify deterioration in the vital sign physiology of an ED patient earlier than current standard monitoring and observation charting techniques.

Detailed description

As well as the potential of the SNAP40 device to improve patient safety, we believe that the SNAP40 device will increase ED efficiency, improve and increase use of resources and enable improved patient flow through the ED. Currently the only option for continuous monitoring or regular observations in the ED is to connect the patient to a standard monitor. Whilst these monitors can be portable they are not lightweight enough to allow the patient to be ambulatory within the ED and therefore require the patient to have a bed and a bed space or cubicle. This leads to lack of space within the ED, less cubicles (which allow privacy) free for performing history taking, examination and procedures, difficulty accessing patients and difficulty transporting them to areas where specialist tests can be performed (i.e. radiology and ECG). SNAP40 may remove the need for patients to be confined to beds and bed spaces (unless clinically required) freeing up space within the ED and allowing the ED care processes to occur much more freely increasing efficiency and speed of patient processing. This will undoubtedly lead to improved patient experiences around their ED and hospital journey. The SNAP40 device also has the potential to free up resources, which can be used to improve patient care and experience in the ED. SNAP40 may reduce clinical staff time taken to record observations enabling them to provide patients with other aspects of care (i.e. analgesia and treatments) more regularly and in a timelier manner. Clinical staff may be able to spend more time with patients allowing better quality communication with them and their relatives. There will potentially be more time for traditional nursing care and personal care. Whilst there are some other similar medical devices on the market (i.e. www.biovotion.com, www.sensium-healthcare.com, www.vitalconnect.com, http://www.caretakermedical.net) using wristbands, patches or finger cuff technology, currently none are being used in ED clinical practice. This study will examine the SNAP40 device by comparing its performance to detect physiological deterioration against standard observations taken by clinical staff (nurses, doctors and clinical support workers) within the ED. The study will assess whether the device is able to detect physiological derangement sooner that standard monitoring devices.

Interventions

DEVICESNAP40

SNAP40 ambulatory monitoring device

Sponsors

SNAP40
CollaboratorUNKNOWN
University of Edinburgh
CollaboratorOTHER
NHS Lothian
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Intervention model description

Addition to standard care

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Participant aged 16 years or over AND 2. Participant triaged to Majors (High Dependency or Immediate Care) OR Participants who are stepped down from Resuscitation room care to High Dependency or Immediate Care

Exclusion criteria

1. Participants under 16 years of age 2. Previous participation in the study 3. Participant in custody 4. Participants deemed high risk for absconding by clinical staff 5. Participants unable to communicate in English 6. Participants who are triaged to immediate resuscitation. These participants may be considered for inclusion once immediate assessment and treatment have been initiated and they are stepped down to High Dependency (HD)/Immediate Care (IC) areas 7. Patients with implantable defibrillators, pacemakers or neurostimulators will be excluded 8. Patients who cannot have blood pressure measured in both arms e.g. patients with renal fistula, a Peripherally Inserted Central Catheter (PICC) line or who have had a lymph node clearance

Design outcomes

Primary

MeasureTime frameDescription
Time to detection of deterioration4 hoursTime to detection of deterioration in an ED patient's vital sign physiology defined as an increase in NEWS score. This would include a deterioration in blood pressure, pulse/heart rate, respiratory rate, skin temperature (SNAP40)/core temperature (Standard), oxygen saturation reading or movement (SNAP40)/GCS (Standard).

Secondary

MeasureTime frameDescription
Staff observation and responding to alarm times4 hoursTime ED staff spend performing a charting observations and responding to standard monitoring alarms.
Percentage clinical escalation of care when deterioration detected.4 hoursPercentage clinical escalation of care when deterioration detected.
Participants satisfaction4 hoursParticipants rating of experience of both SNAP40 and current monitoring.
Staff satisfaction4 hoursED staff rating of experience of both SNAP40 and current monitoring.

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 5, 2026