Skip to content

Correlation Between Radiographic Bone Density in CBCT and Implant Stability Quotient Value: Clinical Observational Study

Correlation Between Radiographic Bone Density in CBCT and Implant Stability Quotient Value: Clinical Observational Study

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03164759
Enrollment
35
Registered
2017-05-24
Start date
2017-06-01
Completion date
2018-06-01
Last updated
2017-05-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Dental Implantation

Brief summary

Correlate the implant stability quotient values measured by ostell device with radiographic bone density measured on CBCT by bluesky software pre-operatively

Detailed description

Dental implants have been widely used in the field of dental rehabilitation. Nowadays implant sucess rate is very high but to keep faliure rate as low as possible patient selection is very important especially regarding bone density to achieve high primary stability. Primary stability plays an important role in successful osteointegration of dental implants. This study was done to correlate between the bone density pre operatively measured on CBCT represented by HF unit and implant stability measured post operatively by ostell device represented by ISQ unit

Interventions

None listed

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
30 Years to 60 Years
Healthy volunteers
Yes

Inclusion criteria

* patients receiving dental implants in both arches * patients should be free from any systemic diseases that may affect normal healing of bone, and predicated outcome * no intra-oral soft tissue defect that would render primary closure of the intra-oral wound

Exclusion criteria

* patients with systemic diseases \_ patients with ridge augmentation such as ridge expansion, ridge splitting and bone grafting * patients with sinus lifting done to place implants * immediate extraction sockets

Design outcomes

Primary

MeasureTime frameDescription
Bone densityBaselineMeasuring bone density on CBCT by bluesky software representing by hounsfield unit pre operatively
Implant stabilityImmediate post operativePost oprative measurements of implant stability by ostell device (ISQ)

Contacts

Primary ContactMohammed B Mohammed, Master
Beso901@yahoo.com00201223232606
Backup ContactAmr H El khadem, Phd
Amrelkhadem@gmail.com01001162401

Outcome results

None listed