Skip to content

Impact of Antibiotic Treatment Following Implantation of Cardiac Electronic Device on Patient's Outcome

Impact of Antibiotic Treatment Following Implantation of Cardiac Electronic Device on Patient's Outcome

Status
UNKNOWN
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03148444
Enrollment
400
Registered
2017-05-11
Start date
2017-06-01
Completion date
2020-06-01
Last updated
2017-05-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Infection, Bacterial, Pacemaker Complication

Brief summary

Background: Infection of cardiac implantable electronic device including wound and pouch infection, bacteraemia and endocarditis is a common complication of device insertion. The role of antibiotic prophylaxis in prevention of this complication is well established. Most centres in Israel currently prescribe antibiotics about 5 days following the procedure as well, though clear clinical evidence warranting this practise is lacking. Unnecessary antibiotic treatment can lead to adverse events including allergy, undesirable effects of the antibiotics, establishment of resistance to antibiotics among bacteria and further infections with resistant strains. Objective: The investigators hope to either establish evidence warranting use of post-procedural antibiotic treatment or refuting it. Methods: The investigators intend to recruit about 400 patients a year into both trial group and control group. The trial group will be treated with post-procedural antibiotics during 5 days, while the control group will receive no post-procedural antibiotics. The endpoints of the study will include infections related to the implantable device and proposed adverse effects of the antibiotics. The t-test will be performed in order to evaluate whether benefit exists concerning one of the groups.

Detailed description

The infection of cardiac implantable electronic device site (including both pocket infection and deeper infections) is a common complication of electronic device insertion. Its incidence is estimated in different series as 0.2-0.7 per 100 device-years. The risk factors that raise the incidence of this complication are in the first place lack of or inappropriate antibiotic prophylaxis and repeated or recurrent manipulations with the device. Several comorbidities such as diabetes, renal insufficiency, heart failure, malignancy, anticoagulation treatment, and, non-surprisingly glucocorticoid treatment are the remaining risk factors for the infection. It is worth mentioning that over half of all cases of infection occur during the first year past implantation. About 75% of all device infections are caused by staphylococci (both S. aureus and coagulase negative staphylococci). The other causative organisms are streptococci, Corynebacterium species, Propionibacterium, gram-negative bacilli and fungi. Main source of infection appears to be pocket contamination by skin flora. In one study the swab specimens obtained from device pockets during the procedure rendered positive culture for coagulase-negative staphylococci in up to one half of the specimens even despite observant aseptic technique and appropriate antibiotic prophylaxis.Thus, the contamination leading to infection of the implantation site can occur during the procedure. Other possible paths for infection include erosion of the device or its leads through the skin and seeding of the device and its leads by systemic bacteremia. The treatment of this complication usually requires explantation of the infected device, intravenous antibiotic treatment and then implantation of a new device through the non-infected route. The principal approach to prevent device infection remain aseptic technique during the procedure and appropriate antibiotic prophylaxis. Different clinical trials showed that pre-treatment of elective patients before the device implantation with anti-staphylococcal penicillins or with first generation cephalosporins results in decrease in rate of infection with odds ratio about 0.2-0.25.Therefore, current recommendation is to pre-treat patients before implantation of the device with 2-3 gram cefazolin or 1.5 gram cefuroxime, or 15 mg/kg vancomycin or clindamycin 900 mg IV within 4 hours before the procedure. Currently there is no evidence regarding adjuvant antibiotic treatment after the implantation. In the face of lack of evidence, several medical centres in Israel either non-uniformly administer different antibiotic regimens following the implantation or refrain from routinely prescribing any antibiotics to the patients following the implantation. Objective: The investigators suppose that non-necessary antibiotic treatment entails several adverse outcomes including direct adverse effects of the antibiotics (e.g. allergy, gastrointestinal effects, QT-prolongation), and induction of resistance to antibiotics among the patient's microflora entailing further infections with resistant bacteria (e.g. urinary tract infections, diarrhea). Therefore, an evidence either warranting use of antibiotics following the implantation of implantable electronic device or refuting it should be established. Medications: 1. cefalexin 500 mg qid, 2. roxithromycin 150 mg bid Both medications are authorized in Israel for a variety of infections or infection prevention including prevention of implantable cardiac electronic device infection. Both medications are routinely prescribed in medical centres in Israel following implantation of cardiac electronic devices.

Interventions

DRUGcefalexin 500 mg qid or roxithromycin 150 mg bid

antibiotics treatment for five days following implantation of cardiac device

Sponsors

Kaplan Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
DOUBLE (Investigator, Outcomes Assessor)

Masking description

The random assignment will be performed by a researcher from the cardiologic team performing the implantation by means of choosing one of two closed envelopes. The treatment will not be placebo-controlled, and therefore the neither the patients nor the attending physicians will not be blinded to the final results of the assignment.

Intervention model description

We propose to organize a randomized open-label study in which patients undergoing de novo implantation or replacement of cardiac implantable devices (single-chamber, dual-chamber and biventricular pacemakers and defibrillators) will be randomly assigned to one of the two groups. Patients in one group will be discharged home with recommendations to take antibiotic treatment for 5 days following the procedure (cefalexin 500 mg qid, or in the presence of beta-lactam sensitivity roxythromycin 150 mg bid) while in the other group no recommendations regarding antibiotic treatment will be given. Both groups will receive antibiotic prophylaxis before the procedure according to the current recommendations. In both groups, the aseptic technique during the procedure will be observed, and proper hygienic measures past the implantation will be taken.

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* patients undergoing de novo implantation or replacement of cardiac implantable devices (single-chamber, dual-chamber and biventricular pacemakers and defibrillators) in our institution.

Exclusion criteria

* procedure during which, according to the opinion of the operator, the risk of the contamination would be unusually high (for ex. due to prolonged duration) so that obligatory post-operative use of antibiotics should be warranted, * patients with any immunosuppressive condition (including cytotoxic chemotherapy, chronic use of glucocorticoids, however excluding diabetes mellitus, renal failure and heart failure); * malignancy, * pregnancy and breastfeeding; * hepatic cirrhosis; * end stage renal disease (GFR\<10 mL/min); * known allergy to both antibiotic medications used in the study.

Design outcomes

Primary

MeasureTime frameDescription
wound infection1 yearoperative wound infection or infection of the device pouch
bacteremia and vegetations1 yearbacteremia due to device infection, lead vegetation, right infective endocarditis
re-operation1 yearre-operation due to infective complications

Secondary

MeasureTime frameDescription
infection unrelated to implantation1 yearany infection (e.g. bacteremia, urinary tract infection, diarrhea) unrelated to the implantable device, whether demanding hospitalization or not
death from any cause1 yeardeath from any cause unrelated to the problems enumerated among primary outcomes
hospitalization1 yearany hospitalization due to non-infective problems related to the implantable device
adverse event of antibiotics1 yearany event related to adverse effect of antibiotics warranting discontinuation of the drug e.g. allergy

Contacts

Primary ContactMoshe Swissa, MD
Swissam@clalit.org.il97250873523
Backup ContactIgor Volodarsky, MD
woland1978@gmail.com972526301769

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026