Skip to content

PAIR Study-PAP And IOP Relationship: Study 2

Positive Airway Pressure and Intraocular Relationship: Study 2- The Impact of CPAP on Nocturnal IOP.

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03145129
Acronym
PAIR2
Enrollment
28
Registered
2017-05-09
Start date
2017-03-24
Completion date
2018-02-10
Last updated
2018-06-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Obstructive Sleep Apnoea, Primary Open-angle Glaucoma

Keywords

Intraocular pressure, IOP, CPAP

Brief summary

Some people with Primary Open-angle Glaucoma (POAG) also suffer from Obstructive Sleep Apnoea (OSA), a common sleep disorder which is known to affect heart and blood vessels, and may contribute to glaucoma progression. Obstructive Sleep Apnoea is treated with Continuous Positive Airway Pressure (CPAP); however using this type of breathing support may raise intraocular pressure (IOP). The evidence for this is limited and the potential mechanisms involved are poorly understood. In this study we will determine whether CPAP applied at night changes IOP and ocular perfusion pressure (OPP). We will also assess its possible impact on ocular microvasculature. Two groups of patients will be included: those with POAG and OSA, and those with OSA without glaucoma. They will attend for two overnight assessments: the first before starting CPAP and the second 4-6 weeks into the treatment. Repeated measurements of IOP at night will be performed and participants will continue self-measuring IOP at home in the day. An Ocular Coherence Tomography Angiography (OCT Angiography) of the optic disc and the surrounding retina will be performed at baseline and after a few weeks of CPAP treatment.

Detailed description

People with OAG and concomitant OSA associated with the relevant symptoms, particularly daytime sleepiness, currently receive standard treatment with CPAP. However, the impact of CPAP on their glaucoma is unknown. There are concerns that CPAP increases IOP, currently the only modifiable factor in glaucoma, though the evidence for this is limited. Understanding the influence of CPAP on IOP is important as it may inform the management of people with OSA and concomitant glaucoma. If CPAP is shown to raise IOP or alter OPP to levels that pose clinical risk it will be necessary to assess available alternative treatment options for OSA. If, however, CPAP does not alter these parameters, there would be a rationale for assessing long-term effects of CPAP, most probably in the form of a randomised interventional trial, informed by the findings of this research. This is a prospective controlled study which will examine the impact of CPAP on nocturnal IOP and OPP in people with OSA with and without POAG. In addition, we will assess ocular microvasculature before and a few weeks into CPAP treatment. Objectives: Primary: to determine if IOP increases at night following treatment with CPAP in people with OSA with and without POAG. Main Secondary:(i) to investigate whether diurnal IOP raises after CPAP treatment; (ii) to investigate whether CPAP alters peri-papillary and macular microcirculation measured with OCT Angiography. Participants: People with newly diagnosed OSA who require treatment with CPAP will be invited. We will recruit participants with POAG and people without glaucoma (control subjects). All participant will undergo a detailed ocular assessment including: visual acuity, IOP measurement, OCT and visual field test. Sample Size: 30 participants: 15 per group. Study Visits: Visit 0: Baseline ocular examination to confirm or exclude glaucoma will be undertaken during this visit unless a participant already had this examination within the last 6 months. Visit 1: Participants will attend the sleep centre (Respiratory Support and Sleep Centre-RSSC, Papworth Hospital) where they will be admitted to a separate ward. Consented participants will undergo the following: Baseline assessment: A brief medical history, spirometry and anthropomorphic measurements. Repeated measurements: IOP will be measured in each eye using a rebound tonometer (Icare Pro, Finland Oy). Blood pressure and ocular perfusion pressure will be checked simultaneously. Participants will be advised to sleep at their habitual hours. Sleep onset and duration will be recorded. All the above measurements will be repeated every 2 hours starting from 10pm and finishing at 8am. In the morning OCT Angiographic will be performed. Participants will then self-measure IOP at home using a rebound tonometer (Icare Home, Finland Oy). The measurements will be performed in the daytime every 2 hours before they start CPAP and 4-6 weeks into the treatment. Visit 2: Participants will return for the second overnight assessment 4-6weeks after initiation of CPAP treatment. CPAP usage data will be downloaded. All the measurements following the same procedure as for Visit 1 will be repeated this time with participants using CPAP. OCT Angiographic will be performed immediately after removing CPAP in the morning.

Interventions

DEVICEContinuous Positive Airway Pressure

Continuous Positive Airway Pressure

Sponsors

Hinchingbrooke Healthcare NHS Trust
CollaboratorUNKNOWN
Papworth Hospital NHS Foundation Trust
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Newly diagnosed, untreated OSA with indications for CPAP * Age \>40 years * Able to give informed consent and attend for the study visits.

Exclusion criteria

* Known or suspected pregnancy * Any contraindications to rebound tonometry, including: corneal scarring, microphtalmos, buphthalmos, nystagmus, keratoconus, abnormal central corneal thickness, corneal ectasia, , active corneal infection, , and corneal dystrophies * Eye diseases known to affect IOP, including: treated wet age related macular degeneration (ARMD), central retinal vein occlusion (CRVO), branch retinal vein occlusion (BRVO), uveitis and diabetic retinopathy. * Indications to start CPAP treatment urgently unless the study visits can be organised in a way there is no delay in treatment initiation. * Irregular sleep pattern * Insomnia * Acute infectious diseases * Inability to undergo screening ophthalmic examination

Design outcomes

Primary

MeasureTime frameDescription
Intraocular pressure (IOP)On completion of study visit 2: 6 weeksDifference between baseline IOP at night and nocturnal IOP on CPAP

Secondary

MeasureTime frameDescription
Diurnal IOP changeOn completion of study visit 2: 6 weeksA difference in diurnal IOP self-measured at home at baseline and during CPAP treatment.
Relationship between change in IOP on CPAP with OSA severityOn completion of study visit 2: 6 weeksCorrelation between IOP change (ΔIOP) and AHI (Apnoea-Hypopnoea Index)
Relationship between change in IOP on CPAP with POAG severityOn completion of study visit 2: 6 weeksCorrelation between IOP change (ΔIOP) and VFI (Visual Field Index)
Differences in change in IOP between the study groupOn completion of study visit 2: 6 weeksDifferences in IOP change (ΔIOP; IOPCPAP -IOPbaseline) between the groups
Optic disc vessel densityOn completion of study visit 2: 6 weeksOptic disc vessel density at baseline and after 4-6 weeks of CPAP treatment
Peripapillary vessel densityOn completion of study visit 2: 6 weeksPeripapillary vessel density at baseline and after 4-6 weeks of CPAP treatment
Ocular Perfusion Pressure (OPP)On completion of study visit 2: 6 weeksDifference between baseline OPP at night and nocturnal OPP on CPAP in each group

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026