Skip to content

Comparison of Patient Satisfaction Using Heated Versus Room Temperature Ultrasound Gel

Comparison of Patient Satisfaction Using Heated Versus Room Temperature Ultrasound Gel: a Single-blind Randomized Controlled Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03135379
Acronym
HUGS
Enrollment
124
Registered
2017-05-01
Start date
2016-04-30
Completion date
2017-04-30
Last updated
2018-08-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ultrasound

Brief summary

The purpose of this single-blind, randomized control trial will be to investigate whether simply having warmed gel, as compared to room-temperature gel, during a bedside ultrasound significantly improves patient satisfaction scores.

Detailed description

ED physicians who identify that a patient will require an ultrasound will page the ultrasound team as part of standard of care. At that time, an investigator will obtain verbal consent from the patient and provide an information sheet to help explain study details/answer any questions. The patient will then be randomized to either warmed gel or room temperature gel. Investigators will handle the gel using a heat-resistant glove (ULine Terry Cloth Glove) to maintain blinding to the gel temperature. A bedside ultrasound study will then be performed by emergency physicians not otherwise involved in the study using the study gel. Immediately upon ultrasound completion, the patients will complete a satisfaction survey. The images from the study will be saved and subsequently reviewed by an emergency physician with fellowship training in ultrasound to score image quality from 1 (low) to 5 (high).

Interventions

DEVICEHeated ultrasound gel

Gel stored in Thermasonic Gel Warmer (Model 82-03 LED, 120V) set to medium setting (102 degree fahrenheit).

Gel stored in Thermasonic Gel Warmer (Model 82-03 LED, 120V) turned off.

Sponsors

Brooke Army Medical Center
Lead SponsorFED

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Investigator)

Masking description

A heat-resistant glove, ULine Terry Cloth Glove (Appendix F), will be used by the investigators to handle the ultrasound gels.

Eligibility

Sex/Gender
ALL
Age
18 Years to 89 Years
Healthy volunteers
Yes

Inclusion criteria

* Adults aged 18-89 years * Patients require bedside ultrasound

Exclusion criteria

* Patients under age 18 * Patients over age 89 * Pregnant women * Altered mental status * Incarcerated * Military basic trainees * Primary language other than English * Patients with open or broken skin over areas requiring ultrasound gel application

Design outcomes

Primary

MeasureTime frameDescription
Patient SatisfactionImmediately upon completion of ultrasound examinationMeasured on 100-mm visual analogue scale. This scale is a horizontal line on a sheet of paper measuring 100 mm. The scale ranges from 0 on the left (representing completely unsatisfied) to 100 on the right (representing completely satisfied). We instructed subjects to draw a single vertical mark through the horizontal line to represent how satisfied they were with their overall emergency department visit.

Secondary

MeasureTime frameDescription
Ultrasound Image QualityWithin 1 week of completion of ultrasound examinationMeasured 1 (low) to 5 (high) by an attending emergency physician who has completed ultrasound fellowship.

Participant flow

Participants by arm

ArmCount
Heated Gel
Patient undergoes ultrasound study using the intervention of heated ultrasound gel. Heated ultrasound gel: Gel stored in Thermasonic Gel Warmer (Model 82-03 LED, 120V) set to medium setting (102 degree fahrenheit).
61
Room Temperature Gel
Patient undergoes ultrasound study using the intervention of room temperature gel. Room temperature gel: Gel stored in Thermasonic Gel Warmer (Model 82-03 LED, 120V) turned off.
59
Total120

Baseline characteristics

CharacteristicHeated GelRoom Temperature GelTotal
Age, Continuous41.5 years
STANDARD_DEVIATION 17.6
42.0 years
STANDARD_DEVIATION 18.5
41.7 years
STANDARD_DEVIATION 18
Race and Ethnicity Not Collected0 Participants
Sex: Female, Male
Female
19 Participants32 Participants51 Participants
Sex: Female, Male
Male
42 Participants27 Participants69 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 620 / 62
other
Total, other adverse events
0 / 620 / 62
serious
Total, serious adverse events
0 / 620 / 62

Outcome results

Primary

Patient Satisfaction

Measured on 100-mm visual analogue scale. This scale is a horizontal line on a sheet of paper measuring 100 mm. The scale ranges from 0 on the left (representing completely unsatisfied) to 100 on the right (representing completely satisfied). We instructed subjects to draw a single vertical mark through the horizontal line to represent how satisfied they were with their overall emergency department visit.

Time frame: Immediately upon completion of ultrasound examination

ArmMeasureValue (MEAN)
Heated GelPatient Satisfaction87.6 units on a scale
Room Temperature GelPatient Satisfaction83.9 units on a scale
Secondary

Ultrasound Image Quality

Measured 1 (low) to 5 (high) by an attending emergency physician who has completed ultrasound fellowship.

Time frame: Within 1 week of completion of ultrasound examination

ArmMeasureValue (MEDIAN)
Heated GelUltrasound Image Quality4 units on a scale
Room Temperature GelUltrasound Image Quality4 units on a scale

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026