Skip to content

Failed Epidural Anesthesia During Labor: Evaluation of Risk Factors and Outcome

Failed Epidural Anesthesia During Labor: Evaluation of Risk Factors and Impact on Labor ,Maternal and Fetal Outcomes

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03129022
Enrollment
500
Registered
2017-04-26
Start date
2017-04-30
Completion date
2018-02-28
Last updated
2017-08-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Vaginal Delivery

Brief summary

Women requesting epidural analgesia will receive a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices (Portex, Smith Medical, Hythe, UK) were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters will be inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% iss initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is established and maintained throughout labor and delivery using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals, continued at the same bolus dose until delivery. Pain was evaluated using a 0-10 cm visual analogue scale (VAS) before, 15 and 30 min after the loading dose followed by hourly assessment until delivery. VAS score assessment was based specifically on abdominal or back pain resulting from contractions

Detailed description

Women requesting epidural analgesia will receive a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices (Portex, Smith Medical, Hythe, UK) were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters will be inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% iss initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is established and maintained throughout labor and delivery using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals, continued at the same bolus dose until delivery. Pain was evaluated using a 0-10 cm visual analogue scale (VAS) before, 15 and 30 min after the loading dose followed by hourly assessment until delivery. VAS score assessment was based specifically on abdominal or back pain resulting from contractions. Failed epidural is defined as VAS score ≥5, 30 min after a loading dose, given after the last attempt. Women who had a repeated attempt due to VAS ≥5 at 30 min or dural puncture or required repositioning of the catheter, resulting in subsequent pain relief expressed as VAS score \<5 were not considered to have a Failed epidural. VAS score is assessed by obstetrician and not the anesthesiologist who performed the block. Furthermore, intrapartum vaginal examinations to assess cervical dilatation and fetal head station were also performed by experienced obstetrician. As part of the study, the women's satisfaction was assessed the morning following delivery using a 1-5 satisfaction scale, where score 1 corresponded to very unsatisfied and score 5 corresponded to very satisfied. Before satisfaction assessment, all women who agreed to participate signed an informed consent and then relevant data was collected from the participants' medical charts.

Interventions

Women requesting epidural analgesia received a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters were routinely inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% was initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is maintained throughout labor using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
19 Years to 40 Years
Healthy volunteers
No

Inclusion criteria

* ≥34 weeks of gestation * receiving epidural analgesia during labor,

Exclusion criteria

* Women who had a planned cesarean delivery, * intrauterine fetal death * non-vertex presentation * delivered at less than 30 min after epidural insertion * contraindication for epidural analgesia (i.e., thrombocytopenia \<100,000 cells/μl, ongoing thromboprophylaxis with low-molecular-weight or unfractionated heparin, and bacteremia or infection at the needle-puncture site)

Design outcomes

Primary

MeasureTime frameDescription
duration of first stage of laborfrom start of cervical dilatation till full cervical dilatationeffect of success and failure of epidural on duration of first stage of labor (..before, 15 and 30 min after the loading dose followed by hourly assessment until delivery..)

Countries

Egypt

Contacts

Primary ContactAhmed Maged, MD
prof.ahmedmaged@gmail.com01005227404
Backup ContactAhmed shaker, MD
asragab1@gmail.com

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026