Skip to content

Comparison of LigaSure to Conventional Electrocoagulation in Video-assisted Thoracoscopic Surgery Lobectomy

Comparison of LigaSure Technology to the Conventional Electrocoagulation in Video-assisted Thoracoscopic Surgery (VATS) Lobectomy Followed by Systemic Lymphadenectomy: A Prospective Randomized Controlled Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03125798
Enrollment
216
Registered
2017-04-24
Start date
2018-05-03
Completion date
2021-11-04
Last updated
2024-09-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Complication of Surgical Procedure, Lung Cancer

Keywords

video-assisted thoracic surgery, LigaSure, mediastinal lymph node dissection

Brief summary

Surgical treatment of lung cancer consists of two elements: anatomical lung resection (segmentectomy, lobectomy or pneumonectomy) followed by mediastinal lymph node dissection (MLND). Since over last 15 years the growing rate of resection is performed by minimal invasive approach - video-assisted thoracoscopic surgery (VATS). The study is focused on the clinical and technical aspects of MLND during VATS lobectomy. The extension of lymph nodes resection is strictly specified. The main benefit of MLND for the patient is precise histopathological staging, which allows choosing the best therapeutic option of adjuvant therapy. MLND is related with potential minor and major complications (bleeding, increased volume of chest tube drainage, prolonged chest tube duration and hospital stay, chylothorax, left recurrent laryngeal nerve injury, injury of the bronchus, injury of the esophagus). The majority of complications are caused by thermal injury resulting from the use of heat-generating monopolar electrocautery that is commonly used during lymph nodes dissection. In addition, thermal energy generation in case of monopolar electrocautery may lead to systemic inflammatory response and increased surgical injury. High-energy sealing devices like LigaSure™ allow for dissection, coagulation and cutting with the single instrument. Compared to mechanical ligation techniques (vessel loops, clips) or monopolar electrocautery, LigaSure™ technology has been shown to reduce: intraoperative blood loss (in colorectal, gynecologic and urologic surgery), surgery time (in colorectal, gynecologic and urologic surgery), length of hospital stay (in gynecologic and urologic surgery). Investigators hypothesize that application of LigaSure™ in VATS anatomical resection may lead to diminished complications rate, lower systemic inflammatory response and shorter length of stay compared to monopolar electrocautery.

Detailed description

Summary Surgical treatment of lung cancer consists of two elements: anatomical lung resection (segmentectomy, lobectomy or pneumonectomy) followed by mediastinal lymph node sampling (MLNS) or mediastinal lymph node dissection (MLND). Since over last 15 years the growing rate of resection is performed by minimal invasive approach - video-assisted thoracoscopic surgery (VATS). This technique is used in at least 60% of patients with lung cancer operated on in the leading centers. The study project is focused on the clinical and technical aspects of MLNS/MLND during VATS lobectomy. Lymphadenectomy has to be performed obligatory in case of lung cancer resection. The extension of lymph nodes resection or sampling is strictly specified and should be the same independently from the surgical approach (thoracotomy or VATS). The main benefit of MLNS/MLND for the patient is precise histopathological staging, which allows choosing the best therapeutic option of adjuvant therapy. It was proved that MLND is superior to MLNS in its accuracy however the improvement of local control of the disease is not proved. Mediastinal lymphadenectomy is related with potential minor and major complications. The risk of complications is low but in case of their occurrence hospital stay is usually significantly prolonged, quality of life decreases and additional surgery may be needed. In very small group of patients complications may lead to severe disability or death. The most frequent complications related with MLND are: 1. Bleeding, sometimes requiring redo surgery; 2. Increased volume of chest tube drainage with prolonged chest tube duration and hospital stay; 3. Chylothorax; 4. Left recurrent laryngeal nerve injury; 5. Injury of the bronchus (especially of posterior part of right main bronchus during dissection of subcarinal lymph nodes); 6. Injury of the esophagus (dissection of subcarinal and paraesophageal lymph nodes). The majority of the above mentioned complications are caused by thermal injury resulting from the use of heat-generating monopolar electrocautery that is commonly used during lymph nodes dissection. Bleeding or chylothorax are usually caused by incomplete blood or lymphatic vessels closure. Esophageal or bronchial wall injury can be caused by thermal injury followed by ischemia, necrosis and finally perforation. The diagnosis is frequently delayed. In addition, thermal energy generation in case of monopolar electrocautery may lead to systemic inflammatory response and increased surgical injury. Extent of surgical injury measured by acute phase proteins levels (c-reactive protein, alpha-1-antitrypsin, alpha-1-acid glycoprotein, haptoglobin) and interleukin levels was proved to be correlated to long-term results in patients with colorectal cancer. Introduction of new high-energy sealing devices like LigaSure™ to clinical practice allows for dissection, coagulation and cutting with the single instrument. Compared to mechanical ligation techniques (vessel loops, clips) or monopolar electrocautery, LigaSure™ technology has been shown to significantly reduce: * Operative blood loss in colorectal, gynecologic and urologic surgery * Perioperative blood transfusions in gynecologic, urologic and general surgery * Procedure time in colorectal, gynecologic and urologic surgery * Length of hospital stay in gynecologic and urologic surgery. There have been no randomized studies comparing the use of traditional electrocautery and LigaSure for lymphadenectomy during VATS resection due to non-small cell lung cancer. Investigators hypothesize that application of LigaSure™ in VATS anatomical resection may lead to diminished complications rate, lower systemic inflammatory response and shorter length of stay compared to monopolar electrocautery. Study design Patients with early stage NSCLC who are routinely operated on by VATS will be randomized into two groups. First group called electro-VATS (Monopolar electrocautery) will be operated on with the use of traditional electrocautery and the second called liga-VATS (LigaSure) with the use of LigaSure. In the first group during the whole procedure (dissection of pulmonary ligament, mediastinal pleura and adhesions, as well as hilar dissection and lymphadenectomy) only traditional monopolar electrocautery will be used. In the liga-VASTS patients only LigaSure will be applied,no monopolar electrocautery will be used. The procedure of VATS lobectomy or segmentectomy will be performed in standardized fashion with separate stapling of hilar vessels and bronchus and lung parenchyma division. The hilar dissection and mediastinal lymphadenectomy will be performed using either monopolar electrocautery or LigaSure according to the randomization. The extent of lymphadenectomy will be the same in both groups and will include stations 2R,4R,7,8R,9R,10R,11R on the right side and stations 5,6,7,8L,9L,10L,11L on the left side. The number of removed lymph nodes will be counted. The extension of lymphadenectomy will be controlled and supervised by main investigator. Deep temperature inside the esophagus at the level approximately 2-3 cm below the carina will be measured during lymphadenectomy in order to assess the differences in the exposure of the surrounding tissues to the thermal energy generated by either LigaSure or electrocautery. The temperature measurement should in some part reflect the potential risk of thermal injury to the esophagus caused by different energy devices. Investigators plan to enroll 200 patients, 100 patients in each group. Initial assessment will include age, gender, comorbidities (Charlson Comorbidity Index, CCI and Thoracic Revised Cardiac Risk Index, thRCRI scores) and pulmonary function tests. The following factors/parameters will be measured/compared in both groups: 24-hour, 48-hour and total volume of chest tube drainage, chest tube duration and hospital stay, rate of the prolonged air leak, rate of redo surgery due to bleeding, rate of postoperative complications related to the procedure, intraoperative blood loss and time of the surgery, local thermal effect, systemic inflammatory response after surgery. Statistical analysis The analyzed data will be presented as means, standard deviations, minimum and maximum values, medians, interquartile ranges (lower quartile, upper quartile) or percentage, as appropriate. Normality of the distribution will be tested with the Shapiro-Wilk's test, and the equality of variances will be checked with the Levene's test. For comparison of groups, unpaired t test or one-way ANOVA (for data which follow normal distribution and homogeneity of variances) or Welch test will be applied. In case data will not normally distributed nonparametric tests will be used - Mann-Whitney U test or the Kruskal-Wallis test with the Dunn's post-hoc test. Categorical data will be analyzed with the χ2 test or the Fisher-Freeman-Halton test. The relationship between variables will be analyzed with the Pearson's linear correlation coefficient or the Spearman's rank correlation coefficient or (and) by multivariate linear regression. All the results will be considered significant at p\<0.05. Statistical analyses will be performed with statistical packages: STATISTICA 10.0 PL (StatSoft. Inc.) or StatXact 9.0 (CytelStudio) software.

Interventions

DEVICELigaSure™

LigaSure™ is supposed to provide improved closure of lymphatic and blood vessels during mediastinal lymph nodes dissection.

Monopolar electrocautery will be used according to the standard technique for the mediastinal lymph node dissection.

Sponsors

Medtronic
CollaboratorINDUSTRY
Wielkopolskie Centrum Pulmonologii i Torakochirurgii
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 85 Years
Healthy volunteers
No

Inclusion criteria

* Surgery performed by Video-Assisted Thoracic Surgery technique (VATS). * Mediastinal Lymph Node Dissection performed due to the European Society of Thoracic Surgeons * Patients must be informed and must sign and give written informed consent.

Exclusion criteria

* Preoperative radiotherapy. * Preoperative chemotherapy. * Mediastinoscopy or other surgical procedures of mediastinum prior to the present surgery. * Chest surgery on the side to be operated. * Conversion from VATS to thoracotomy

Design outcomes

Primary

MeasureTime frameDescription
Postoperative Chest Drainage Volume up to Chest Drain Removal, Average 3 Days.Total postoperative chest drainage volumeMeasurement of the postoperative volume of fluid drained in milliliters, measured up to chest drain removal, average 3 days.

Secondary

MeasureTime frameDescription
Acute Phase Proteins Levels.72 hours after surgeryChange in C-reactive protein (CRP) level, calculated as the difference between CRP values \[mg/L\] at 72 hours after surgery and 24 hours before surgery
Local Temperature.During mediastinal lymph nodes dissection (during surgery)Change in the intraesophageal temperature at the level of the subcarinal lymph nodes, calculated as the difference between the highest temperature during subcarinal nodes dissection and the temperature before subcarinal nodes dissection

Countries

Poland

Participant flow

Participants by arm

ArmCount
LigaSure
In this arm, LigaSure™ will be used for mediastinal lymph nodes dissection, according to standard surgical technique. LigaSure™: LigaSure™ is supposed to provide improved closure of lymphatic and blood vessels during mediastinal lymph nodes dissection.
100
Monopolar Electrocautery
In this arm, conventional monopolar electrocautery will be used for mediastinal lymph nodes dissection, according to standard surgical technique. Monopolar electrocautery: Monopolar electrocautery will be used according to the standard technique for the mediastinal lymph node dissection.
100
Total200

Withdrawals & dropouts

PeriodReasonFG000FG001
Overall StudyConversion to thoracotomy77
Overall StudyLack of electrosurgical device in the operating room20

Baseline characteristics

CharacteristicLigaSureMonopolar ElectrocauteryTotal
Age, Continuous65.9 years
STANDARD_DEVIATION 7.4
66.4 years
STANDARD_DEVIATION 7.3
66.2 years
STANDARD_DEVIATION 7.3
Race (NIH/OMB)
American Indian or Alaska Native
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Asian
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Black or African American
0 Participants0 Participants0 Participants
Race (NIH/OMB)
More than one race
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
0 Participants0 Participants0 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants0 Participants0 Participants
Race (NIH/OMB)
White
100 Participants100 Participants200 Participants
Region of Enrollment
Poland
100 participants100 participants200 participants
Sex: Female, Male
Female
42 Participants42 Participants84 Participants
Sex: Female, Male
Male
58 Participants58 Participants116 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 1000 / 100
other
Total, other adverse events
24 / 10022 / 100
serious
Total, serious adverse events
0 / 1000 / 100

Outcome results

Primary

Postoperative Chest Drainage Volume up to Chest Drain Removal, Average 3 Days.

Measurement of the postoperative volume of fluid drained in milliliters, measured up to chest drain removal, average 3 days.

Time frame: Total postoperative chest drainage volume

ArmMeasureValue (MEDIAN)
LigaSurePostoperative Chest Drainage Volume up to Chest Drain Removal, Average 3 Days.550 ml
Monopolar ElectrocauteryPostoperative Chest Drainage Volume up to Chest Drain Removal, Average 3 Days.580 ml
Secondary

Acute Phase Proteins Levels.

Change in C-reactive protein (CRP) level, calculated as the difference between CRP values \[mg/L\] at 72 hours after surgery and 24 hours before surgery

Time frame: 72 hours after surgery

ArmMeasureValue (MEDIAN)
LigaSureAcute Phase Proteins Levels.68.5 mg/L
Monopolar ElectrocauteryAcute Phase Proteins Levels.69.2 mg/L
Secondary

Local Temperature.

Change in the intraesophageal temperature at the level of the subcarinal lymph nodes, calculated as the difference between the highest temperature during subcarinal nodes dissection and the temperature before subcarinal nodes dissection

Time frame: During mediastinal lymph nodes dissection (during surgery)

ArmMeasureValue (MEDIAN)
LigaSureLocal Temperature.-0.1 degree Celcius
Monopolar ElectrocauteryLocal Temperature.-0.1 degree Celcius

Source: ClinicalTrials.gov · Data processed: Feb 12, 2026