The objective is to determine whether the test product, Methotrexate 40 mg/mL solution for injection administered subcutaneously by the prefilled and needle-free delivery system Zeneo®, and the reference product, Methotrexate Biodim® 25 mg/mL, solution for injection administered subcutaneously by a conventional syringe with needle are bioequivalent.
Detailed description
ABSTRACT Objective: Zeneo1 is a needle-free injection device. We performed a pharmacokinetic study to investigate the bioequivalence of methotrexate administered subcutaneously using either the needle-free injection device or a conventional needle and syringe. Research design and methods: This was a single-dose, open-label, laboratory-blind, randomized crossover study performed in adult healthy volunteers. Each participant received two methotrexate injections (each 25mg), one via needle-free injection device and one via conventional injection, with a 21-28 day wash-out interval between dosing. For each participant, the administration site for both injections was either the abdomen or the thigh. Main outcome measures: The primary pharmacokinetic outcome parameters were AUC(0-t) and Cmax. Bioequivalence was assessed by standard criteria: whether 90% confidence intervals of geometric mean ratios for the two administration methods were within 80-125%. Results: Fifty-two individuals completed the study. Bioequivalence criteria were met for AUC(0-t), for the overall analysis (both injection sites: 90% confidence interval: 99.4-103.1%), and for each injection site separately. Bioequivalence was similarly demonstrated with AUC(0-1). Bioequivalence criteria for Cmax were fulfilled for abdominal administration but not for the overall analysis. Injection via the needle- free injection device was well tolerated. Limitations: Limitations include conducting the study in healthy volunteers and the relatively small subject number (albeit satisfactory for bioequivalence). Conclusions: This study shows that methotrexate injection via needle-free injection device is bioequivalent to a conventional needle and syringe in relation to AUC(0-t) and AUC(0-1). Studies of needle-free injection device use in patients requiring methotrexate therapy are planned.
Interventions
0.625 mL of methotrexate solution 40 mg/ML for subcutaneous injection with a prefilled and needle-free delivery system
1 mL of methotrexate solution 25 mg/mL for subcutaneous injection with a conventional needle and syringe injection
Sponsors
Study design
Eligibility
Inclusion criteria
* Healthy subjects * BMI between 18.5 and 30 kg/m2 * Body mass \> 60 kg * Non-tobacco user * Written consent given for participation in the study
Exclusion criteria
* Evidence of clinically relevant oral, cardiovascular, hematologic, gastrointestinal, hepatic, renal, endocrine, pulmonary, neurologic, psychiatric or skin disorder * Heavy alcohol consumption and regular exposure to drug of abuse
Design outcomes
Primary
| Measure | Time frame |
|---|---|
| Maximum observed plasma concentration (Cmax). | serial pharmacokinetic plasma concentrations were drawn prior pre-dose and post-dose at 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 6, 8, 10, 12, 16 and 24 hours |
| Area under the plasma concentration versus time curve (AUC) time zero to time of the last quantifiable concentration (AUC(0-t)). | serial pharmacokinetic plasma concentrations were drawn prior pre-dose and post-dose at 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 4, 6, 8, 10, 12, 16 and 24 hours |