Skip to content

Thoracic Fluid Content in Prediction of Failure of Weaning From Mechanical Ventilation

The Impact of Thoracic Fluid Content Measured by Cardiometry on Prediction of Failure of Weaning From Mechanical Ventilation

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03094390
Enrollment
64
Registered
2017-03-29
Start date
2017-04-04
Completion date
2018-09-10
Last updated
2019-06-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mechanical Ventilation Complication

Brief summary

This study aims to test the accuracy of the total thoracic fluid content (TFC) measured by cardiometry can predict weaning failure. Area under receiver operating characteristic curve (AUROC) will be determined, sensitivity, specificity, and best cutoff value will be calculated for TFC in prediction of weaning failure.

Detailed description

Weaning from mechanical ventilation is a serious and challenging process in critical care practice. Weaning failure is associated with poor patient outcomes. Increased mortality in patients with failed weaning was due to development of complications related to re-intubation. Detection and correction of the cause of failed spontaneous breathing trial (SBT) helps the intensives to improve the outcome of the next trials. Fluid overload and positive cumulative fluid balance is a risk factor of weaning failure in both cardiac and non-cardiac patients. Many tools for prediction of lung congestion as a risk factor for weaning failure have been reported. The gold standard for detection of cardiac cause of weaning failure was pulmonary artery catheter. More simple tools had been investigated for detection of cardiac cause of weaning failure in patients with or without previous cardiac dysfunction such as extravascular lung water and B-natriuretic peptide (BNP) levels. Although measurement of extravascular lung water is a reliable tool for prediction of cardiac cause of weaning failure, it has the disadvantage of the need of advanced monitor with invasive arterial line. Bioreactance is a new technology used for measurement of cardiac output and total thoracic fluid content (TFC). More recently, electrical velocimetry is a newer technology with good performance in cardiac output monitoring. The use of electrical velocimetry in measurement of TFC has the advantage of being non-invasive with no need for advanced skills. The aim of this work is to validate the use of TFC (measured by electrical velocimetry) in prediction of weaning outcome.

Interventions

None listed

Sponsors

Cairo University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients aged 18 years or more scheduled for a spontaneous weaning trial (SBT) on pressure support ventilation.

Exclusion criteria

* Age \< 18 years old. * Pregnant patients. * Neuromuscular disease (stroke, myasthenia gravis and Guillain-Barrésyndrome). * Tracheostomy.

Design outcomes

Primary

MeasureTime frameDescription
Total thoracic fluid content (TFC)5 minutes before spontaneous breathing trialthe value of TFC measured by cardiometry device (in liters)

Secondary

MeasureTime frameDescription
rapid shallow breathing index5 minutes before spontaneous breathing trial.the respiratory rate divided by the tidal volume (in liters)
P/F ratio5 minutes before spontaneous breathing trial and 5 minutes before patient extubationpressure of arterial oxygen (in mmHg) divided by fraction of inspired oxygen
fluid balanceduring the last 24 hours before the weaning trialthe total fluid intake minus the fluid output (in liters)

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026