BIO|MASTER.Edora Family Study

BIO|MASTER.Edora Family Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03091322
Enrollment
120
Registered
2017-03-27
Start date
2017-02-12
Completion date
2019-12-02
Last updated
2020-05-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cardiac Resynchronization Therapy, Pacemaker Therapy

Brief summary

This study is designed as post market clinical follow-up study with CE-marked products to evaluate the AV Opt and LV VectorOpt features in the respective Edora family pacemakers under clinical conditions. Furthermore, adverse events will be evaluated to identify residual risks associated with the use of the BIOTRONIK Edora family pacemakers. The study is further designed to address potential regulatory needs of clinical data for countries and regions not covered by the CE approval.

Detailed description

Study Design * Open-label, prospective, non-randomized, multicenter, international * about 13 study sites Study Endpoints The following endpoints are defined and will be assessed with descriptive analysis: 1. AV Opt feature: The feature's AV delay recommendation was 1. used as basis for the device programming or is at least considered to be clinically acceptable or 2. other AV delay values were chosen by the investigator and the recommendation was rated as not clinically acceptable. 2. LV VectorOpt usability using an overall score (categories: excellent, good, average, fair, poor). 3. (S)ADEs and calculation of the SADE free rate until the 6-month follow-up

Interventions

DEVICEPacemaker of the Edora Family (Edora/ Evity/ Enitra/ Enticos) 8

Assessment of the AV Opt and LV VectorOpt features

Sponsors

Biotronik SE & Co. KG
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Standard indication for pacemaker therapy or cardiac resynchronization therapy * Patient is able to understand the nature of the study; * Patient provides written informed consent; * Patient is able and willing to complete the planned follow-up visits at the investigational site; * Patient accepts Home Monitoring® concept; * Age ≥ 18 years.

Exclusion criteria

* Any contraindication for pacemaker or cardiac resynchronization therapy (whichever applies); * Patient has received or is planned to receive an epicardial LV lead implant; * Pregnant or breast-feeding; * Life expectancy of less than 6 months; * Participation in an interventional clinical investigation

Design outcomes

Primary

MeasureTime frameDescription
AV delay recommendation by the AV Opt Feature was either used for the device programming or was rated as clinically acceptable.until the 1-month follow-upThe AV Opt Feature will be assessed only for patients with triple-chamber devices and patients with dual-chamber devices (if clinically indicated) with sinus rhythm of sufficient intrinsic rate. According to the clinical investigation plan this endpoint will be assessed with descriptive analysis methods.
Overall score for the usability of the LV VectorOpt featureuntil the 1-month follow-upThe LV VectorOpt feature has to be assessed for patients with an HF-T device (triple-chamber) and a QP lead (quadripolar, HF-T QP group) only. According to the clinical investigation plan this endpoint will be assessed with descriptive analysis methods.
(S)ADEs and calculation of the SADE free rateuntil the 6-month follow-upDescriptive analysis of all (S)ADEs and calculation of the SADE free rate

Countries

Austria, Germany, Spain, Switzerland