Durability of Flexible Ureteroscopes and Causes of Infection During Flexible Ureterorenoscopy

Durability of Flexible Ureteroscopes and Causes of Infection During Flexible Ureterorenoscopy

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03087812
Enrollment
400
Registered
2017-03-23
Start date
2015-12-31
Completion date
2017-12-31
Last updated
2018-04-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Kidney Stones

Keywords

Microbiological burden, kidney, stone, durability of flexible endoscopes

Brief summary

This is an observational study in which data on consecutive patients who undergo ureterorenoscopy with the use of a flexible ureterorenoscope are collected. In total 20 new ureteroscopes are usedfrom Olympus andfrom Storz) to study the durability of the ureteroscopes and the possible microbiological load.

Detailed description

This is an observational study in which data on consecutive patients who undergo ureterorenoscopy with the use of a flexible ureterorenoscope are collected. In total 6 new ureteroscopes are used (3 from Olympus and 3 from Storz) to study the durability of the ureteroscopes and the possible microbiological load. Before the procedure is started the endoscope is tested for its microbiological load in two different ways:1. Shake the tip of the flexible ureterorenoscope 5 seconds in a sterile container filled with 10 cc of NaCl 0.9% 2. Flush the working channel of the ureterorenoscope with 10 cc of NaCl 0.9% and collect the sample in a sterile container. After the procedure is finished, the endoscope is tested for its microbiological load in two different ways: 1\. Shake the tip of the flexible ureterorenoscope 5 seconds in a sterile container filled with 10 cc of NaCl 0.9% 2. Flush the working channel of the ureterorenoscope with 10 cc of NaCl 0.9% and collect the sample in a sterile container. Transfer all samples to the lab as soon as possible but at least within four hours after collecting the samples. As for the clinical efficacy during each procedure a detailed questionnaire about the use of each ureteroscope is filled out. This includes the ease of use making mention on quality of the image, torque, flexibility and durability. Data will be collected through electronic case report forms (eCFRs), with use of an online Data Management system (DMS).

Interventions

None listed

Sponsors

Clinical Research Office of the Endourological Society
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient presented with a diagnosis to undergo a ureterorenoscopy using a flexible ureterorenoscope * over 18 years * has signed informed consent * the patient is being treated with the designated flexible ureterorenoscope

Design outcomes

Primary

MeasureTime frameDescription
Microbiological load2 yearsTo evaluate the pre-operative microbiological load of the tip and the working channel of the most common used flexible ureteroscopes, after high level disinfection

Secondary

MeasureTime frameDescription
Durability2 yearsTo evaluate the durability of the most common used flexible ureteroscopes in terms of number of procedures, total use time and total degrees of flexibility loss until the first repair is needed.
Factors affecting durability2 yearsTo evaluate descriptive data on factors that may affect the durability of the flexible ureteroscopes. Factors measured are treatment time, treatment indication and anatomical location in the urinary tract, method of ureteroscope insertion number and type of accessory instrumentation through the working channel, difference in users, number of forcing the scope during the procedure and the number of disinfections.