Molecular Breast Imaging in Screening Breast Cancer

Molecular Breast Imaging in Screening Breast Cancer

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03082456
Enrollment
164
Registered
2017-03-17
Start date
2015-06-01
Completion date
2019-06-01
Last updated
2020-05-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast Cancer

Keywords

molecular breast imaging, MBI, breast cancer, mammography, sonography, recall rate, diagnostic accuracy, breast echo, female population

Brief summary

The molecular breast imaging (MBI) is a potential modality to screen breast cancer. In this study, we compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and aim to determine best ways of breast cancer screening.

Detailed description

Keywords: molecular breast imaging, MBI, breast cancer, mammography, sonography 1. Background: In breast cancer screening, the sensitivity of mammography is about 71-96 %, but the sensitivity decreases in the three following groups: (1) under 50 years old; (2) dense breast parenchyma; (3) higher risk of breast cancer. The Health and Welfare Ministry data in recent 2 years showed Taiwanese women accepted mammography for screening in the ratio of only about 36%, representing many missed opportunities for early detection. One reason to reject mammography may be the discomfort caused by compression. To solve the above mammography possible weakness, other screening methods came into being, such as molecular breast imaging (MBI) of nuclear medicine. Radiotracer of Tc-99m sestamibi was found for targeting breast tumor 20 years ago, and approved by the FDA in 1997. However, the application is limited due to the suboptimal scanning camera design. Ten years later, the Mayo Clinics developed MBI technology, using small-sized semiconductor detectors. Then it become possible that the nuclear technologist have patient's breast tissue fit the detector in almost the same fashion of mammography without heavy compression. 2. Objective: The aim of this study is to evaluate the recall rate and diagnostic accuracy of MBI, mammography and breast echo, for female population. 3. Study design: Female patients referred to Nuclear Medicine Department for myocardial perfusion scan will be recruited in this study. It is because that MBI and myocardial perfusion scan share the same radiotracer. Then MBI will become additional scanning only. About 1800 female subjects will involve, and further mammography and/or breast sonography will be arranged within 6 months after MBI. Participants will be encouraged to receive mammography every 2 years and telephone survey. We hope that this study will help us to compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and to determine best ways of breast cancer screening.

Interventions

Molecular breast imaging will be performed at 5-10 minutes after intravenous injection of 15-20 millicurie (mCi) Tc-99m sestamibi. Both craniocaudal (CC) view and mediolateral oblique (MLO) images of the breast are taken.

DIAGNOSTIC_TESTMammography

During the procedure, the breast is compressed using a dedicated mammography unit. Parallel-plate compression evens out the thickness of breast tissue to increase image quality by reducing the thickness of tissue that x-rays must penetrate, decreasing the amount of scattered radiation, reducing the required radiation dose, and holding the breast still (preventing motion blur). Both craniocaudal (CC) view and mediolateral oblique (MLO) images of the breast are taken.

DIAGNOSTIC_TESTBreast ultrasound

Ultrasound investigation of breast is performed by members of breast cancer team. If abnormality is found by the procedure, biopsy will not be performed directly.

Sponsors

Chang Gung Memorial Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
SCREENING
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
45 Years to 69 Years
Healthy volunteers
Yes

Inclusion criteria

* Female patients undergoing myocardial perfusion imaging will be eligible if they sign the informed consent.

Exclusion criteria

* They are unable to understand and sign the consent form * They are physically unable to sit upright and still for 20 minutes. * They have undergone breast surgery or breast biopsy within the last 12 months. * They have had trauma to the breast tissue or undergone radiation treatment to the breast within the last 12 months.

Design outcomes

Primary

MeasureTime frameDescription
Recall rate6 monthsThe frequency with which a radiologist or physician interprets findings of an examination as positive

Secondary

MeasureTime frameDescription
Diagnostic efficacy6 monthsThe sensitivity, specificity, positive predictive value and negative predictive value of each imaging modality

Countries

Taiwan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026