Skip to content

Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment

Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment - A Randomized Controlled Trial About Stability and Patients' Perceptions

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03070444
Enrollment
104
Registered
2017-03-03
Start date
2009-11-12
Completion date
2021-06-18
Last updated
2022-08-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Orthodontics, Retention

Keywords

Essix retainer, Vacuum-formed retainer, Cuspid-to-cuspid retainer

Brief summary

The purpose of this trial is to evaluate and compare stability after orthodontic treatment with an Essix retainer and a bonded cuspid-to-cuspid retainer (CTC), respectively in the mandibular arch and longitudinally follow these patients over time up to 5 years. The patients' perceptions of the two methods are also evaluated with questionnaires during the follow-up period. A further aim of this study is to analyze the relationship between diagnosis, treatment outcome, treatment time, age at start of treatment and stability with an Essix retainer in the maxilla. The null hypotheses are: * that there is no difference in retention capacity between Essix retainer and cuspid-to-cuspid retainer * that there is no difference in patients' perception between Essix retainer and cuspid-to-cuspid retainer * that there is no difference in retention capacity for Essix retainer in the maxilla concerning diagnosis before treatment, treatment outcomes, treatment time and age at start of treatment

Detailed description

The study is conducted at the Orthodontic Clinic, Gävle, Sweden and consists of 104 patients. All patients are treated with fixed appliances in the upper and lower jaw (standard .022 straight wire), both with and without extractions. The patients are randomized into two groups with 52 patients in each group (Group A: cuspid-to-cuspid retainer, Group B: Essix retainer). Dental cast are obtained at the debond appointment (T1) and at the follow-up controls after six months (T2), 18 months (T3) and 60 months (T4) for both groups. At the visit two weeks in retention and at the follow-up visits after 6, 18 and 60 months the patients assess questionnaires in order to evaluate their experience of retention with the retention device.

Interventions

DEVICECTC retainer

The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding.

DEVICEEssix retainer maxilla

The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances.

DEVICEEssix retainer mandible

The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances.

Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months.

OTHERQuestionnaire

A questionnaire is completed at the follow-up visits.

Sponsors

Umeå University
CollaboratorOTHER
Region Gävleborg
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Healthy volunteers
Yes

Inclusion criteria

* Patients treated with fixed appliances in both the maxilla and the mandible

Exclusion criteria

* Rapid Maxillary Expansion (RME) for patients with severe transversal malocclusion * Treatment with segmented appliances * Patients with craniofacial anomalies and patients requiring orthognatic surgery * Patients with missing mandibular incisor

Design outcomes

Primary

MeasureTime frameDescription
Changes in Tooth PositionChanges in tooth position (Little's Irregularity Index) were analysed 5 years (T4) after debonding (T1)Analyses of changes in tooth position on dental casts Little's Irregularity Index (in mm) 0=no crowding/irregularity, higher scores= more crowding/irregularity (worse outcome)

Secondary

MeasureTime frameDescription
Patients' PerceptionT4 (5 years follow up)Analyses of patients' perception by validated self-report questionnaires to evaluate experiences of the retention techniques VAS (visual analog scale, 0-100) 0= low satisfaction 100= high satisfaction

Participant flow

Participants by arm

ArmCount
Group A: CTC Retainer + Essix Retainer
The CTC is bonded directly after debonding. The Essix retainer maxilla is handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. CTC retainer: The CTC retainer consists of 0.8 hard Remanium® wire (Dentaurum, Germany) and is bonded with Tetric Flow (Ivoclar Vivadent, Liechtenstein) to the lower canines directly after debonding. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits.
52
Group B: Essix Retainer + Essix Retainer
The Essix retainer maxilla and Essix retainer mandible are handed out to the patient the same day after removal of fixed appliances. Alginate impressions are taken at the follow-up visits. Questionnaires are completed at the follow-up visits. Essix retainer maxilla: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Essix retainer mandible: The Essix retainer is made of 1 mm Essix C+® Plastic (Dentsply, USA) and is handed out to the patient the same day after removal of fixed appliances. Alginate impression: Alginate impressions are taken to made the cuspid-to-cuspid and Essix retainers, respectively. Dental casts are obtained at the debond appointment and at the follow-up visits after 6, 18 and 60 months. Questionnaire: A questionnaire is completed at the follow-up visits.
52
Total104

Baseline characteristics

CharacteristicGroup A: CTC Retainer + Essix RetainerGroup B: Essix Retainer + Essix RetainerTotal
Age, Continuous17.1 years
STANDARD_DEVIATION 1.9
17.1 years
STANDARD_DEVIATION 2.4
17.1 years
STANDARD_DEVIATION 2.2
Ethnicity (NIH/OMB)
Hispanic or Latino
0 Participants0 Participants0 Participants
Ethnicity (NIH/OMB)
Not Hispanic or Latino
0 Participants0 Participants0 Participants
Ethnicity (NIH/OMB)
Unknown or Not Reported
52 Participants52 Participants104 Participants
Region of Enrollment
Sweden
52 participants52 participants104 participants
Sex: Female, Male
Female
26 Participants26 Participants52 Participants
Sex: Female, Male
Male
26 Participants26 Participants52 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 520 / 52
other
Total, other adverse events
0 / 520 / 52
serious
Total, serious adverse events
0 / 520 / 52

Outcome results

Primary

Changes in Tooth Position

Analyses of changes in tooth position on dental casts Little's Irregularity Index (in mm) 0=no crowding/irregularity, higher scores= more crowding/irregularity (worse outcome)

Time frame: Changes in tooth position (Little's Irregularity Index) were analysed 5 years (T4) after debonding (T1)

Population: Dental casts were analysed. As data were not normal distributed, median values are reported.

ArmMeasureValue (MEDIAN)
Group A: CTC Retainer + Essix RetainerChanges in Tooth Position0.05 millimeters
Group B: Essix Retainer + Essix RetainerChanges in Tooth Position0.62 millimeters
p-value: 0.000295% CI: [0.48, 1.51]GEE analysis
Secondary

Patients' Perception

Analyses of patients' perception by validated self-report questionnaires to evaluate experiences of the retention techniques VAS (visual analog scale, 0-100) 0= low satisfaction 100= high satisfaction

Time frame: T4 (5 years follow up)

Population: Adolescent patients at debond (baseline), adults after 5 years

ArmMeasureValue (MEDIAN)
Group A: CTC Retainer + Essix RetainerPatients' Perception93 score on a scale
Group B: Essix Retainer + Essix RetainerPatients' Perception92 score on a scale
p-value: 0.55Wilcoxon (Mann-Whitney)

Source: ClinicalTrials.gov · Data processed: Feb 20, 2026