Prospective Sensor Controlled Compliance Analysis of Shoulder Abduction Splint After Rotator Cuff Repair

Prospective Sensor Controlled Compliance Analysis of Shoulder Abduction Splint After Rotator Cuff Repair

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03054753
Acronym
SENSABDUKT
Enrollment
46
Registered
2017-02-16
Start date
2017-03-31
Completion date
2021-07-01
Last updated
2021-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Rotator Cuff Tear

Keywords

Abduction brace, Compliance, Rotator cuff tear, Rotator cuff repair

Brief summary

The postoperative shoulder rehabilitation in an abduction brace after rotator cuff reconstruction of the shoulder is crucial for a successful healing of the reconstruction. In this study the investigators want to analyse the abduction brace-wearing time using a electronic sensor, which is implanted in the abduction brace. The participants will be informed about the sensor after completion of the abduction brace rehabilitation 6 weeks postoperatively.

Detailed description

After arthroscopic reconstruction of a rotator cuff tear the healing depends on a tension free positioning of the reconstructed tendon. Therefore a abduction brace is administered routinely for 6 weeks. The re-rupture rate of rotator cuff reconstruction is about 30%. One of the reason may be mechanical overuse caused by non wearing of the abduction brace. From experience the investigators suggest that the abduction brace wearing behaviour differs among patients. The participant´s wearing compliance has been evaluated by Silverio et al. with a questionary but never with a sensor. In this study the investigators want to analyse the participant´s abduction brace wearing compliance by using an sensor, which is implanted in the abduction brace and monitors the wearing time, which reveals the objective wearing time. The sensor is a certificated sensor, which measures temperature in °C every 15 min. If the abduction brace is worn by the participants the body temperature can be captured by the sensor. If the measured temperature is over 33°C the sensor capture the time period as a worn time. With this measurements the abduction brace wear time should be captured objectively. A similar kind of sensors were used to evaluate the wearing time of scoliosis-braces in patients with adolescent idiopathic scoliosis (Miller DJ eta al., Morton A et al., Takemitsu et al.) With a questionary the participants are asked of the wearing time before they will be informed about the implanted sensor. This answer represents the subjective wearing time. The first endpoint of the study is the evaluation of the objective and subjective abduction wearing time. The second endpoint is the evaluation of the correlation between compliance and subjective outcome.

Interventions

BEHAVIORALAbduction brace wearing time analysis

To evaluate the patient´s abduction brace wearing time a sensor = Orthotimer® (Rollerwerk, 72336 Balingen, Germany, www.orthotimer.com) is implanted in the abduction brace. The sensor measures the body temperature of the patient. Through that the wearing time can be evaluated.

Sponsors

Balgrist University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
16 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Patients with rotator cuff repair and postoperative abduction for 6 weeks

Exclusion criteria

* Revision surgery

Design outcomes

Primary

MeasureTime frameDescription
Objective abduction brace wearing time6 weeks postoperativeA sensor is implanted in the abduction brace, which captures every 15min. the temperature. If the abduction brace is worn the sensor can measure the body temperature. The objective wearing time can be evaluated.

Secondary

MeasureTime frameDescription
Correlation of compliance and functional outcome1 year postoperativeCompliance: Constant score: Compliance= objective wearing time a day in correlation to functional outcome (Shoulder Constant score 0-100pts)
Correlation of compliance and subjective outcome3 months postoperativeCompliance:subjective shoulder value Compliance = objective wearing time a day in correlation to subjective shoulder value
Correlation of compliance and patient satisfaction3 months postoperativeCompliance: patient satisfaction Compliance = objective wearing time a day in correlation to patient satisfaction (excellent =4, good =3, moderate=2, poor=1)

Countries

Switzerland

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026