Reproducibility Study of Transcranial Doppler

Reproducibility Study of Transcranial Doppler Microembolic Signals Detection in the Middle Cerebral Artery

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03050567
Enrollment
40
Registered
2017-02-13
Start date
2017-03-17
Completion date
2017-08-09
Last updated
2018-06-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Stroke

Keywords

Microemboli

Brief summary

Hardening of the neck vessels (carotid arteries) caused by fatty deposits called 'plaques' is a common cause of strokes. Over time plaques can burst or may lead to a severe narrowing (stenosis) of the neck artery. When plaques burst, small clots or fatty particles (called microemboli) break off, block brain vessels and lead to a stroke. Researchers have an incomplete understanding of the processes that cause hardening of the arteries, development of small clots and are unable to predict who will have a stroke. At present, the only ultrasound scan that evaluates circulation in the head and detects these small clots is called the Transcranial Doppler ultrasound. The aim of the study is to test this simple ultrasound technique to see if it can detect signals that may correspond to these small clots or fatty particles. The other objective is to see how repeatable the ultrasound technique is. This may help to identify patients with hardened neck arteries who are at higher risk of a recurrent stroke. This could also potentially improve patients selection to a targeted surgical or future novel pharmacological therapy.

Interventions

Transcranial Doppler will be performed on the symptomatic (ipsilateral to an index event) middle cerebral artery in a quiet temperature controlled room. The middle cerebral artery will be identified through the temporal window in a supine position with a flow direction towards the probe. The subject will have a head frame (Marc 600 Spencer Technologies, USA) fitted to reduce motion and to secure a constant angle of the middle cerebral artery insonation depth at 50-60 mm from the skull surface. All recordings will be made using the ST3 Transcranial Doppler Ultrasound System (Spencer Technologies, USA) with a 2-MHz transducer for 1 hour. Emboli will be detected by listening for their characteristic short audible sound (range 10-100 ms, intensity threshold above 7 dB) and spectral appearance using the International Consensus Group microembolus identification criteria and an automated Embolus Detection Software (Spencer Technologies, USA).

Sponsors

University of Edinburgh
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Healthy volunteers with no previous history of cerebrovascular disease and aged over 18 years old. * Patients with symptomatic cerebrovascular event (stroke, transient ischaemic attack or amaurosis fugax) and image confirmed carotid artery stenosis of \>30%. This will include patients scheduled for carotid endarterectomy (\>50% for men and \>70% for women, by North American Symptomatic Carotid Endarterectomy Trial criteria) or treated conservatively with an optimal medical therapy (if patient declined surgical intervention or is outside surgical criteria for carotid endarterectomy).

Exclusion criteria

* Subjects unable to comply with the study procedures such as a severe disabling stroke. * Inadequate temporal window for Transcranial Doppler assessment. * Adults with incapacity.

Design outcomes

Primary

MeasureTime frame
Presence of microembolic signals in the Middle Cerebral Artery.14 days