Eye Movements, Perception, Simulation Training, Task Performance and Analysis
Conditions
Keywords
Eye-tracking, High Fidelity Simulation Training, Visual Perception
Brief summary
The aim of this observational study is to compare the visual interests between residents in high-fidelity simulation practice
Detailed description
Eighteen first year residents were asked to take part in a nine-minute scenario based on an ACLS bradycardia algorithm in which a high-fidelity mannequin required external pacing. The scenario was considered a success if the material was correctly set by the participant to obtain electrical and mechanical pacing in nine minutes. All participants were wearing Tobii Glasses® which is a mobile eye-tracking system that automatically aggregates gaze data. Infrared markers were placed in the simulation room to create Area of Interest (AOI), from which results were obtained. Three AOI were created: the vital signs monitor, the defibrillator/pacing unit and the head of the patient. Eye-tracking data were analyzed using the Tobii Studio® program.
Interventions
A 9-minute scenario based on an ACLS bradycardia algorithm in which a high-fidelity mannequin requires external pacing
Sponsors
Study design
Eligibility
Inclusion criteria
* First-year residents from various specialties in their first three weeks of training
Exclusion criteria
* Underwent a previous residency * Attending physicians in another country
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Time to first fixation, Total visit time | During the scenario | Using eye-tracking technology, gaze date can be aggregate onto Areas of interest where data can be extrapolated. |