Skip to content

Effects of GlucoClear CGM System on the Performance of Insulin Therapy in Critically Ill Patients

A Study on the Effects of the Use of GlucoClear CGM System on the Performance of Insulin Therapy in Critically Ill Patients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03047824
Acronym
GlucoClearIT
Enrollment
100
Registered
2017-02-09
Start date
2014-05-31
Completion date
2015-06-30
Last updated
2017-03-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Metabolic Stress Hyperglycemia

Brief summary

After providing written informed consent, the first 20 Subjects meeting Inclusion/Exclusion Criteria will be consecutively enrolled in the Standard of Care cohort. The moderate treatment cohort will then be consecutively enrolled, followed by the tight glycemic control cohort. After sensor insertion, baseline evaluations including APACHE II, SOFA, and laboratory evaluations will be determined. Subjects enrolled in the standard of care cohort will be treated according to the institution's protocol for measuring glucose and managing insulin. These subjects will be monitored on a GlucoClear System but they will not be managed based on the values or trends of the GlucoClear system. Subjects enrolled in the treatment cohorts will be monitored and managed with a special version of the GlucoClear continuous monitoring system. This system contains the GlucoClear Insulin Dosing Algorithm providing insulin dosing recommendations to enable the clinician to manage patient glucose within pre-specified target levels. These recommendations are presented on screen for a clinical professional to approve or override. Subjects in the moderate treatment cohort will have their glucose managed in the range of 120 - 180 mg/dl. Subjects in the tight glycemic control treatment cohort will be managed in the range of 80 - 120 mg/dl. After discharge from the ICU, subjects will followed for adverse events and mortality at 30 days, either by telephone contact or office visit.

Detailed description

Hyperglycemia, hypoglycemia and glycemic variability, the three components of dysglycemia are independently associated with morbidity and mortality of critically ill patients. Blood glucose (BG) control with insulin has the potential to decrease morbidity and mortality of intensive care unit (ICU) patients. Blood glucose control with insulin, however, is associated with an increased risk of hypoglycemia and its effect on glycemic variability is uncertain. BG control with insulin utilizing manual systems for glucose measurement is blood-consuming and time-consuming, since frequent blood draws for glucose measurements are necessary in order to achieve blood glucose control. Severe hypoglycemia (blood glucose level \< 40 mg/dl) is a feared complication of blood glucose control with insulin. Undoubtedly, with implementation of blood glucose with insulin the incidence of hypoglycemia increases. Reported incidences of severe hypoglycemia rise by 5 to 10-fold as compared to conventional glucose control strategies in randomized controlled trials. Several reports showed a significant association between hypoglycemia and patient outcomes. Recently, an association has even been suggested between moderate and mild hypoglycemia (blood glucose level between 40-69 mg/dL) and patient outcomes. Incidences of moderate hypoglycemia are more prevalent than severe hypoglycemia. The risk of developing (severe or moderate) hypoglycemia hampers, at least in part, broad implementation of blood glucose control with insulin, in particular when aiming at normal blood glucose levels \[17,18\]. Recent studies showed also significant associations between glycemic variability and patient outcomes. BG control algorithms, if properly applied, could decrease glycemic variability. Experimentally, rodent experiment showed that brain damage was not associated with the duration of severe hypoglycemia, but instead with its correction (mainly overcorrection) with intravenous dextrose causing formation of radicals. Hence, a close glucose monitoring to prevent overcorrection is mandatory. These different arguments strongly support the need for reliable and accurate CGM. The GlucoClearTM Continuous Glucose Monitoring system from Edwards Lifesciences measures blood sugar by Glucose Oxidase Sensing Technology through in-blood measurement. Blood is automatically drawn and analyzed every 5 minutes from a peripheral venous catheter, with real time graphical display. Blood is then returned to the patient and the system automatically self-calibrates. The GlucoClear CGM is designed to be highly accurate. In a recent study performed in critically ill patients, it was shown to comply with the required standards of quality. The main research question addressed by the present study is: To which extent a CGM-guided strategy improve the quality of BG control performance?

Interventions

DEVICEIntravascular continuous monitoring

Bedside usual insulin therapy guided by continuous glucose monitoring

OTHERStandard of care

Bedside usual insulin therapy guided by intemittent glucose monitoring

Sponsors

Edwards Lifesciences
CollaboratorINDUSTRY
Erasme University Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Caregiver)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Have an anticipated ICU stay of at least 48 hours; * Participate or have authorized representative participate in the Informed Consent process and sign/date the approved informed consent form. * Have an expected ICU stay of ≥ 24 hours up to 72 hours * Have an APACHE II score of ≥ 10, within the first 24 hours of ICU admission. * Not be participating in any other investigational interventional study. * Have hyperglycemia (BG \> 150 mg/dl) up to 6 hours after admission and / or ongoing insulin therapy. * Access to a large peripheral vein

Exclusion criteria

* End stage pre-existing medical conditions that would preclude the subject from being able to complete up to 72 hours of glucose monitoring and follow up (14 ± 3 days after Sensor removal); Restricted peripheral venous access, inadequate access for reference sampling or any contraindication to the placement of peripheral IV catheters. * Skin conditions or existing (or planned) medical instrumentation and/or dressings that preclude placing the peripheral IV catheters or dressings (e.g., extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis, or surgical dressings). * A known history of heparin-induced thrombocytopenia or any contraindication for anti-coagulation therapy. * Intolerance to Lactated Ringer's solution ((mEq/liter): Sodium 130; Potassium 4; Calcium 3; Chloride 110; Lactate 28). * A positive pregnancy test 72 hours prior to Sensor insertion (for subjects of child bearing potential). * Any condition that, in the opinion of the Investigator, would interfere with their participation in the Study. * Participated in any other drug, device, or biologic Study within the last 30 days (prior to Sensor insertion) which may clinically interfere with this Study or have not completed the required Protocol follow-up period.

Design outcomes

Primary

MeasureTime frameDescription
Time in target72 hoursCumulative time in target band (expressed in percentage) will be calculated from the set of BG values recorded by the CGM in both groups.

Secondary

MeasureTime frameDescription
Hypoglycaemic index72 hoursArea under the low limit of the target range
Glycemic variability72 hoursCoefficient of variation
Mortality28 daysICU, hospital and 28-day mortality
Length of stay28 days
SOFA score72 hours
Time to target72 hoursTime to achieve the upper limit of target range (hours)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026