Detection of Breast Lesions by Automatic Breast US

Detection of Breast Lesions by Automatic Breast US (Comparison to Current Hand Held US and Pathological Findings When Exist).

Status
UNKNOWN
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03047122
Enrollment
1200
Registered
2017-02-08
Start date
2017-03-01
Completion date
2018-12-31
Last updated
2017-03-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Breast, Ultrasonography

Keywords

Breast, ultrasonography

Brief summary

Mammography is considered the standard imaging method for breast cancer screening, and is known to result in reduced mortality from breast cancer. However, the diagnostic yield of mammography depends particularly on breast tissue density, with sensitivity as low as 30-48% in dense-breast women. Ultrasound is an attractive adjunct imaging method to mammography as it is widely accessible, relatively inexpensive and well-tolerated by patients. The addition of hand-held ultrasound to mammography has been demonstrated to significantly increase breast cancer detection in women with dense breasts. It is however dependent on the expertise and skill of the operator. In recent years, the FDA has approved the use of the automated breast ultrasound (ABUS) for use in screening of women with dense breast. Unlike handheld ultrasound, the ABUS is relatively simple to use, necessitating less technical training, and results in higher reproducibility. The research aim is to evaluation of automated breast ultrasound (ABUS) regarding the detection and classification of breast lesions, compared to hand-held ultrasound, according to the American College of Radiology Breast Imaging-Reporting and Data System (BI-RADS) classification. The investigator will also evaluate parameters regarding patients' comfort, workflow, and duration of image interpretation.

Detailed description

ABUS produces a 3D volume acquisition using a 6-15 Mega Herz reverse curve transducer. Images are digitally reformatted on a dedicated workstation to produce axial, sagittal and coronal reformatted images. Unlike handheld ultrasound, the ABUS is relatively simple to use, necessitating less technical training, and results in higher reproducibility. Previous studies have shown that automated breast ultrasound is very well tolerated by patients can be useful in detection of solid and cystic lesions and in evaluating tumor extent preoperatively. Automated breast ultrasound will be performed on the Invenia ABUS (Automated Breast Ultrasound System) designed for automated breast imaging by General Electric (GE) Healthcare. Images will be acquired using a 15 centimeter field-of-view reverse curve ultra-broadband transducer of 6-15 Mega Herz. Using mechanical compression assist, the transducer is placed on each breast and six volumes are acquired with six sweeps (right anterior-posterior, right lateral, right medial; left anterior-posterior, left lateral, left medial). Acquisition time expected 15 minutes per patient, approximately 30-40 second acquisition per volume. ABUS examinations will be performed by the investigators institution's radiographers, with variable degrees of experience in performing hand-held breast ultrasound examinations (HHUS). Reformatted images and volumes will be view on a designated workstation of 2 megapixel high resolution monitor, using customized hanging protocols, multi-slice 3D viewing and patented clinical algorithms. Interpretation of images will be done by our institution's breast imaging radiologists with more than 15 years of experience in performing and reading hand-held breast ultrasound studies. Each breast will be assigned a final ABUS BI-RADS score according to the American College of Radiology classification ranging from 1 to 6. A discrepancy between the ABUS Breast Imaging-Reporting and Data System score and the hand-held ultrasound BI-RADS score (HHUS BI-RADS 1-2 & ABUS BI-RADS \>2, or HHUS BI-RADS \>3 & ABUS BI-RADS 1-2) will result in the referral of the woman to second-look hand-held ultrasound to determine the reason for the mismatch.

Interventions

None listed

Sponsors

Assuta Medical Center
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
FEMALE
Age
25 Years to 99 Years
Healthy volunteers
Yes

Inclusion criteria

Women referred to hand-held screening ultrasound examination (BI-RADS=1/2). Women scheduled to undergo ultrasound-guided needle biopsy due to suspicious breast mass detected during hand-held ultrasound (BI-RADS\>2).

Exclusion criteria

Women under 25 years.

Design outcomes

Primary

MeasureTime frameDescription
ability to identify all US breast findings correctly.6 monthThe investigators will compare all lesions detected by abus and hand held US to pathology when present .

Countries

Israel

Contacts

Primary ContactMichal Guindy, MD
micahlgu@assuta.co.il+972-50-8800102