Skip to content

Whole-Body 3D T1-weighted MR Imaging Anatomical Sequences: GE mDixon vs FSE (View) Approaches in Prostate Cancer.

Whole-Body 3D T1-weighted MR Imaging Anatomical Sequences: GE mDixon vs FSE (View) Approaches in Prostate Cancer. Comparison of Diagnostic Performance of GE mDixon and FSE, for Bone and Node Staging in Patients With Prostate Cancer.

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03034070
Acronym
TFE-TVE
Enrollment
30
Registered
2017-01-27
Start date
2016-12-31
Completion date
2019-03-01
Last updated
2019-05-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Metastasis, Prostate Adenocarcinoma

Keywords

MRI, MRI sequences, prostate cancer, cancer, staging, bone metastasis, node metastasis

Brief summary

This study will assess and compare the diagnostic performances and image quality of two WB 3D T1-weighted MR imaging sequences for bone and node staging in patients with prostate cancer : the FSE sequence and a gradient echo (GE) sequence. The latter sequence's main feature is its acquisition time of approximately 1.5 minutes, compared to 18 min for the FSE sequence, reducing the exam's acquisition time, patient discomfort and increasing machine availability.

Detailed description

Whole-body (WB) magnetic resonance (MR) imaging has increasingly been used for the screening of bone and soft-tissue metastases in patients with prostate cancer (1). A limitation for its implementation is the 45-60 minutes duration of current WB MRI examinations. Conventional WB MR imaging studies consisted of anatomical two-dimensional (2D) T1-weighted and fat-suppressed fluid-sensitive (proton-density fat-saturated (PDFS) or short-tau inversion-recovery (STIR)) and of a functional diffusion-weighted imaging sequence. Recent research has confirmed the feasibility of replacing the 2D anatomical sequences by a single three-dimensional (3D) T1-weighted fast spin echo (FSE) sequence (2). This study will assess and compare the diagnostic performances and image quality of two WB 3D T1-weighted MR imaging sequences for bone and node staging in patients with prostate cancer : the FSE sequence and a gradient echo (GE) sequence. The latter sequence's main feature is its acquisition time of approximately 1.5 minutes, compared to 18 min for the FSE sequence, reducing the exam's acquisition time, patient discomfort and increasing machine availability. The aim of this study is to evaluate the feasibility of the replacement of the WB 3D T1-weighted FSE MR imaging sequence by the WB 3D T1-weighted GE MR imaging sequence.

Interventions

DIAGNOSTIC_TESTDiagnostic performance 3D T1

Although non-invasive, the prospective addition of a new MRI sequence to a routine MRI protocol is considered by our ethical committee as an interventional study.

Sponsors

Cliniques universitaires Saint-Luc- Université Catholique de Louvain
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

* prostate cancer with high risk for metastases

Exclusion criteria

* contraindications to MRI

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic performances of 3D GE T1 sub-sequences3 monthsSensitivity, sensibility, positive and negative Predictive Values (PV) will be calculated with the results of each reading, and compared. The physical parameters of the different techniques will also be compared (Signal-to-noise ratio, contrast-to-noise ratio, ...).

Countries

Belgium

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026