Skip to content

Total Knee Arthroplasty Videofluoroscopy

Kinematics Analysis: Comparison Between the Cruciate Retaining, Fixed Bearing Primary Total Knee Arthroplasty ATTUNE TM Knee System and the Fixed Bearing PFC Sigma Curved Total Knee Arthroplasty

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT03033940
Enrollment
19
Registered
2017-01-27
Start date
2016-10-31
Completion date
2018-12-31
Last updated
2019-12-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Total Knee Anthroplasty

Brief summary

The primary objective is to quantify and compare the three-dimensional kinematics of the cruciate retaining (CR), fixed bearing ATTUNETM TKA to the kinematics of the PFC Sigma Curved CR Fixed Bearing TKA (both DePuy Synthes, Johnson and Johnson) during daily activities. The secondary objective is to describe the kinematics in terms of range of motion, patterns of anterior-posterior motion of the nearest medial and lateral points (posterior femoral rollback) and tibio-femoral internal/external rotation as well as the kinetics during daily activities, such as level gait, a deep knee bend (only ATTUNETM subjects), sitting down onto a chair, standing up from a chair and stair descent by means of video-fluoroscopy. Furthermore, the encoded data will be handed over to DePuy Synthes (Johnson and Johnson) and to the Center for Orthopaedic Engineering of the University of Denver, where it will be used within a musculoskeletal model with the aim of simulating tibiofemoral contact mechanics and changes in the musculoskeletal system due to the TKA.

Interventions

Sponsors

Dr. Renate List
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Unilateral TKA (ATTUNETM/Sigma) due to osteoarthritis * BMI ≤ 33 * Good clinical outcome, KOOS \> 70 * No or very low pain VAS \< 2 * At least one year post-op * Standardized general health survey score (SF-12) within the normal range for people in their age group

Exclusion criteria

* Actual significant problem on lower extremities * Misaligned TKA * Any other arthroplasty at the lower extremities * Patient incapable to understand and sign informed consent * Incapable of performing the motion tasks * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Comparison of the three-dimensional kinematics of the cruciate retaining (CR), fixed bearing ATTUNETM TKA to the kinematics of the PFC Sigma Curved CR Fixed Bearing TKA3 hoursWith video-fluoroscopic assessment it is possible to directly measure the kinematics of the tibial and the femoral components in vivo during daily activities, such as level walking, a deep knee bend (only ATTUNETM subjects), sitting down onto a chair, standing up from a chair and stair descent. Thus, for the first time the present study provides in vivo assessed data of the 3D motion of the ATTUNETM System during daily activities and allows a comparison to a conventional TKA based on the same methodology. The knowledge of the in vivo kinematic behaviour of the ATTUNETM System in comparison to the conventional TKA leads to an improved understanding of the design principle.

Countries

Switzerland

Outcome results

None listed