Skip to content

High Flow Nasal Cannula Versus Non-Invasive Ventilation in Exacerbations of Chronic Obstructive Pulmonary Disease

High Flow Nasal Cannula Versus Non-Invasive Ventilation in Exacerbations of Chronic Obstructive Pulmonary Disease and Hypercapnic Respiratory Failure

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03033251
Acronym
HiFOLD
Enrollment
30
Registered
2017-01-26
Start date
2018-09-02
Completion date
2026-07-01
Last updated
2025-05-20

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Acute Hypercapnic Respiratory Failure, Acute Respiratory Distress, Exacerbation Copd

Keywords

COPD exacerbation, Work of breathing, Non invasive ventilation, High Flow Oxygen Cannula, Acute Hypercapnic Respiratory Failure

Brief summary

Chronic obstructive lung disease is a disabling disease that affects people usually after several years of smoke tobacco exposure and affects millions of patients worldwide. The disease is marked by multiples episode of worsening, termed exacerbations necessitating frequent hospitalizations. During these exacerbations, patients present breathless, and in the most severe cases, are admitted to an Intensive Care Unit (ICU) for respiratory assistance. Currently, respiratory assistance is provided by a ventilator via a oronasal mask (referred to non-invasive ventilation, NIV), that helps patients to cope with their breathless. The mask is not always well tolerated and the ventilator sessions are delivered intermittently. In the past decade, a new technique that provides air-oxygen with high flow has been developed. This technique, called High Flow via Nasal Cannula (HFNC) can deliver from 21 to 100% heated and humidified air-oxygen at a high flow of gas via simple nasal cannula. Recent studies have shown that the technique is very efficient to treat patients presenting with acute respiratory failure who don't have any underlying chronic pulmonary disease. Whether the technique would be also efficient in patients with COLD presenting with severe exacerbations has not yet been demonstrated. Since HFNC does not require any mask, it is thought that the comfort of the patient would be much better in comparison to NIV and could potentially help to treat many patients with the disease. The objective of the present study is to study the physiological effect of HFNC as compared to NIV in patients with severe exacerbations of COPD and to show that it is non-inferior to NIV.

Detailed description

Design: Prospective, observational, cross-over, clinical physiologic study of HFNC and NIV in patients with COPD and hypercapnic respiratory failure Intervention: Participants will be consecutively ventilated with the two devices, i.e., HFNC and NIV. HFNC 30 and 50 L/min will be applied in a random order (sealed, opaque envelope). HFNC will be set with a temperature at 37°C or 34°C if perceived as too warm. NIV settings will be adjusted based on the clinical assessment of the Respiratory Therapist as per standard practice and will not be modified during the test. In both groups, FiO2 will be adjusted to achieve a SpO2 of at least 92%. Setting: The intervention will be applied in the Medical-Surgical ICU of St. Michael's Hospital. Duration: Each device will be studied for up to 30 minutes. The entire study will take place over up to 3 hours. There is no additional follow-up thereafter. Procedures: The study will start first by recording patients under spontaneous breathing considered as a baseline (sequence #1). Under spontaneous breathing, patients will be receiving oxygen therapy as it is usually done between 2 NIV sessions. Then, the patient will have up to 30 minutes to acclimatize to HFNC and select his/her preferred flow rate (sequence #2). NIV will be applied (sequence #3). The NIV settings will be adjusted based on the clinical assessment of the Respiratory Therapist and will not be modified throughout the study. Then, according to randomization order (sealed envelopes), patients will receive a flow corresponding to the preferred flow selected by the patient and a second flow, either HFNC 30 L/min or HFNC 50 L/min depending on the initial choice (sequences #4 and #5) (see flow diagram). FiO2 will be adjusted to achieve a SpO2 of 90 to 94%. Each condition will be studied fup to 30 minutes and will be separated by a 5-minute washout period during which patients will be receiving oxygen therapy. The measurements will be collected at baseline (under spontaneous breathing) and during the last five minutes of each condition. In case of clinical intolerance as considered by the attending physician, the study will stop. In case the patient is considered dependent of NIV by clinicians, we will still enroll the patient without doing baseline period after discussion with clinicians. The pulse oximeter (SpO2) and transcutaneous CO2 monitor (SenTec Digital Monitoring System (SDMS)) will be continuously monitored throughout the study period. Exspiron or Electrical Impedance Tomography (EIT) device will be calibrated to measure minute ventilation. Four surface electrodes will be placed bilaterally to record each hemidiaphragm activity using a specific recording system (Acqknowledge software, Biopac Systems) A bedside ultrasound examination will be performed, using a SonoSite system (Fujifilm) equipped with a 10-15 MHz ultrasound linear probe. Diaphragm thickness will be measured both at end-inspiration and end-expiration. This technique will be applied at the end of each sequence (before ventilatory assist under conventional O2 therapy). In patients becoming rapidly intolerant to NIV disconnection, we will limit this baseline period under O2 to a minimum (5 minutes). The thickness and contraction of the intercostal muscles and abdominal muscles will also be assessed. Interpretation of the ultrasound results to determine diaphragm and other muscle thickness will be read at a later time by an individual blinded to the intervention.

Interventions

DEVICENon Invasive Ventilation

Patients will receive non invasive ventilation as a standard of care.

DEVICEHigh Flow Oxygen Cannula 50

Patients will receive High Flow Oxygen Cannula with a flow set at 50 L/min

DEVICEHigh Flow Oxygen Cannula 30

Patients will receive High Flow Oxygen Cannula with a flow set at 30 L/min

Sponsors

Unity Health Toronto
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Participants will receive 2 treatments (non invasive ventilation and high flow nasal cannula). The high flow nasal cannula will be applied with 2 flows (50 L/min and 30 L/min). The order of application of the 2 high flow sequences will be randomized (sealed opaque enveloppes).

Eligibility

Sex/Gender
ALL
Age
40 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. COPD exacerbation and acute hypercapnic respiratory failure with acute respiratory failure defined by * Respiratory acidosis (pH ≤7.35 and PaCO2 ≥45 mmHg); * Respiratory rate≥20 breaths/min; * Activation of accessory respiratory muscles; 2. Undergone at NIV or HFNC since their admission 3. English speaking 4. Adult patient with age \> 40 year old.

Exclusion criteria

1. Severe respiratory acidosis defined by pH\<7.25 2. Decreased level of consciousness (Glasgow Coma Score Scale \< 11) 3. Urgent intubation required 4. Pneumothorax with pleural drainage and persistent air leak 5. Hemodynamic instability requiring vasopressors 6. Uncooperative 7. Patients with skin or chest wall or abdominal trauma (potentially worsened by placement of a surface sensor) 8. Clinical judgement of the attending physician 9. Body mass index \> 40 kg/m2

Design outcomes

Primary

MeasureTime frameDescription
Change in work of breathing between NIV and HFNC30 minutesThe primary endpoint is to compare the decrease in work of breathing under HFNC to the decrease in work of breathing under NIV. The work of breathing will be assessed with diaphragm ultrasound (measurement of the diaphragm thickening fraction).

Secondary

MeasureTime frameDescription
Change in Work of breathing between HFNC 50 and 30 L/min30 minutesThe secondary endpoints include comparison of the work of breathing under HFNC (50L/min vs 30 L/min). The work of breathing will be assessed with diaphragm ultrasound (measurement of the diaphragm thickening fraction).

Countries

Canada

Contacts

Primary ContactLaurent Brochard, MD
BrochardL@smh.ca+1 416 864 5686
Backup ContactMartin Dres, MD
DresM@smh.ca+1 416 692 7420

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 24, 2026