HIFLO ENDO-High Flow Nasal Cannula in GI Endoscopy

HIFLO ENDO- Use of High Flow Nasal Cannula Oxygenation to Increase Patient Safety During Upper GI Endoscopy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03028688
Enrollment
262
Registered
2017-01-23
Start date
2017-06-21
Completion date
2019-05-09
Last updated
2022-07-21

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anesthesia Morbidity

Brief summary

Millions of patients undergo upper GI endoscopy in the United States each year. A large number of these patients have anesthesia to assist with their comfort during the procedure. The majority of patients do not have a protected airway during the procedure, meaning there is no endotracheal tube. Instead the current standard of care is to give supplementary oxygen via nasal cannula. Because patients are deeply sedated or have general anesthesia there is a risk for low oxygen saturation during the procedure, which presents a significant patient safety issue. The purpose of the clinical trial is compare the current anesthesia standard of care against high flow nasal cannula oxygen delivery during anesthesia. The investigator's hypothesis is that high flow nasal cannula oxygen delivery will decrease the frequency with which patients experience hypoxemia during anesthesia for upper GI endoscopy.

Interventions

Participants will receive high flow nasal cannula oxygen delivery during anesthesia. Participants will also have transcutaneous PCO2 measurements performed using a cutaneous electrode.

Sponsors

Anesthesia Patient Safety Foundation
CollaboratorOTHER
University of Maryland, Baltimore
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
PREVENTION
Masking
SINGLE (Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

1. Having Upper GI endoscopy expected to last greater than 15 minutes with anesthesia. 2. Age greater than or equal to 18 years

Exclusion criteria

1. Propofol, midazolam, or fentanyl allergy 2. Pre-procedure plan for general anesthesia with an endotracheal tube (at the discretion of the attending anesthesiologist) 3. Any procedure with planned electro-cautery as a high-inspired oxygen concentration could increase the risk for airway or esophageal fire.

Design outcomes

Primary

MeasureTime frameDescription
Hypoxemia event (Low blood oxygen level)The outcome variable will be measured one time 24 hours after the completion of the patient's anesthesia.The primary outcome measure will be occurrence of a low blood oxygen level defined by oxygen saturation less than 92% for greater than 15 seconds at any point during the patient's anesthesia. This will be a dichotomous outcome variable analyzed by time to event.

Secondary

MeasureTime frameDescription
Hypercarbia event (Elevated blood CO2 level)The outcome variable will be measured one time 24 hours after the completion of the patient's anesthesia.The secondary outcome measure will be occurrence of an elevated blood carbon dioxide level defined as 20 mmHg above the patient's baseline value at any time during their anesthesia. This will be a dichotomous outcome variable analyzed by time to event.
Hypotension event (Low blood pressure)The outcome variable will be measured one time 24 hours after the completion of the patient's anesthesia.The secondary outcome measure will occurrence of low blood pressure defined as blood pressure 25% below baseline value any time during the patient's anesthesia. This will be a dichotomous outcome variable analyzed by time to event.

Countries

United States

Outcome results

None listed