Skip to content

Optimal Insertion Depth of Left Internal Jugular Vein Catheter in Infants

External Validation of Predictive Formula for Optimal Insertion Depth of Left Internal Jugular Venous Catheter in Infants

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03025178
Enrollment
46
Registered
2017-01-19
Start date
2017-03-08
Completion date
2018-04-01
Last updated
2019-09-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Central Venous Catheter, Infant

Brief summary

We previously performed a study to create formula for the optimal insertion depth of left internal jugular vein catheter in infant, which was registered at cris.nih.go.kr. We found that two calculation methods using height and the distance between landmarks (0.11 × height (cm) + 0.19 and 1.02 × I-A-B (cm) + 1.55, where I was insertion point of needle, A was the most prominent point of the sternal head of the left clavicle, and B was the midpoint of the perpendicular line drawn between the sternal head of the right clavicle and an imaginary line between the nipples) were clinically feasible to determine the insertion depth of left internal jugular vein catheter. In this study, we will compare the actual insertion depth with the insertion depth determined from above two calculation methods in other 46 infants.

Detailed description

determine the optimal insertion depth of left internal jugular vein catheter in infants

Interventions

PROCEDURE4Fr central venous catheter insertion

The central venous catheter is placed at left internal jugular vein in infant, and its tip is confirmed by transthoracic echocardiography.

Sponsors

Seoul National University Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 1 Years
Healthy volunteers
Yes

Inclusion criteria

* An infant requiring a central venous catheter during surgery

Exclusion criteria

* Extracardiac vascular anomaly * Dextrocardia * Anatomical abnormality in neck and thorax

Design outcomes

Primary

MeasureTime frameDescription
The actual insertion depth of central venous catheterAbout 5 minutes during central venous catheterization (10 minutes after anesthetic induction)The actual insertion depth of central venous catheter placed at left internal jugular vein

Secondary

MeasureTime frameDescription
The differences between the actual insertion depth and the predicted insertion depth derived from two calculation methodsAbout 5 minutes during central venous catheterization (10 minutes after anesthetic induction)The differences between the actual insertion depth and the predicted insertion depth derived from two calculation methods

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026