Skip to content

Utility of Non-invasive Carboxyhemoglobin and Total Hemoglobin Measurement in the Emergency Department

A Multi-Center Study on the Utility of Non-invasive Carboxyhemoglobin and Total Hemoglobin Measurement in Emergency Department Patients

Status
Terminated
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03017742
Enrollment
813
Registered
2017-01-11
Start date
2016-11-30
Completion date
2017-12-11
Last updated
2022-07-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Anemia, Carbon Monoxide Poisoning

Brief summary

The purpose of this study is to determine the clinical utility of triage screening for anemia and carbon monoxide poisoning (COP) in the ED setting.This is a prospective, nonrandomized, multi-center study of the performance of simultaneous non-invasive testing for two common disorders (COP and anemia). We will determine the limits of agreement and performance characteristics of non-invasive carboxyhemoglobin (SpCO) and hemoglobin (SpHb) values compared to standard blood tests for measurement of carboxyhemoglobin and hemoglobin, in the emergency department setting.

Interventions

DEVICEPulse Oximeter

Sponsors

Masimo Corporation
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
1 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 1 year or older. * At least one digit has acceptable width as measured by study-provided digit gauge. * Presenting to emergency department for any complaint. * Potential for IV catheter and/or blood draw for CBC as standard of care.

Exclusion criteria

* Patients unable to consent for any reason * Patients with fingernail polish, discoloration or trauma to fingers

Design outcomes

Primary

MeasureTime frameDescription
Difference Between SpCO and COHbUp to 3 hoursMeasure the difference between noninvasive carboxyhemoglobin (SpCO) and carboxyhemoglobin determined by co-oximeter measurement of blood (COHb) as calculated in terms of standard deviation. The average difference between paired Masimo noninvasive carboxyhemoglobin (SpCO) and reference carboxyhemoglobin (COHb) determined by co-oximeter measurement of blood represented as mean bias.
SpCO Detection of Carbon Monoxide Poisoning (COP)up to 3 hoursDiagnostics performance of SpCO for detecting COP measured by sensitivity and specificity compared to COHb.
Utility of SpCO as a Screening Tool for Carbon Monoxide Poisoningup to 3 hoursSurveying healthcare providers whether SpCO screening lead to identification of occult toxicity
Carbon Monoxide (CO) Elimination Pharmacokinetics in Relation to Oxygen Administrationup to 3 hoursCO elimination will be evaluated as a function of administered oxygen.
Specificity of SpHb in Detecting Anemia.up to 3 hoursSpecificity in detecting true non-anemic subjects as determined by co-oximeter reference analyzer.
Sensitivity of SpHb Detection of Anemia.up to 3 hoursSensitivity in detecting true anemic subjects as determined by co-oximeter reference analyzer.
SpHb Utility for Screening Anemiaup to 3 hoursEstablish SpHb threshold that predicts the clinical outcome for acute treatment of anemia

Countries

Turkey (Türkiye)

Participant flow

Participants by arm

ArmCount
Test Group
The subjects enrolled in the test group will receive the pulse oximeter Pulse Oximeter
740
Total740

Withdrawals & dropouts

PeriodReasonFG000
Overall StudyProtocol Violation36
Overall StudyWithdrawal by Subject37

Baseline characteristics

CharacteristicTest Group
Age, Categorical
<=18 years
52 Participants
Age, Categorical
>=65 years
129 Participants
Age, Categorical
Between 18 and 65 years
559 Participants
Race and Ethnicity Not Collected— Participants
Region of Enrollment
United States
740 participants
Sex: Female, Male
Female
399 Participants
Sex: Female, Male
Male
341 Participants

Adverse events

Event typeEG000
affected / at risk
deaths
Total, all-cause mortality
0 / 813
other
Total, other adverse events
0 / 813
serious
Total, serious adverse events
0 / 813

Outcome results

Primary

Carbon Monoxide (CO) Elimination Pharmacokinetics in Relation to Oxygen Administration

CO elimination will be evaluated as a function of administered oxygen.

Time frame: up to 3 hours

Population: No COHb elimination pharmacokinetics data was collected.

Primary

Difference Between SpCO and COHb

Measure the difference between noninvasive carboxyhemoglobin (SpCO) and carboxyhemoglobin determined by co-oximeter measurement of blood (COHb) as calculated in terms of standard deviation. The average difference between paired Masimo noninvasive carboxyhemoglobin (SpCO) and reference carboxyhemoglobin (COHb) determined by co-oximeter measurement of blood represented as mean bias.

Time frame: Up to 3 hours

Population: 140 subjects excluded due to: 35 subjects: no valid reference COHb measurements available 17 subjects: no SpCO measurements available 65 subjects: COHb sample more than 10 minutes from the SpCO measurement. 22 subjects: low SpCO confidence value~1 subject: invalid reference measurement (COHb) Target subject sample size of 3000 was not met to evaluate difference between SpCO and COHb. The results are reported in terms of standard deviation.

ArmMeasureValue (MEAN)Dispersion
Test GroupDifference Between SpCO and COHb2.01 percentStandard Deviation 2.49
Primary

Sensitivity of SpHb Detection of Anemia.

Sensitivity in detecting true anemic subjects as determined by co-oximeter reference analyzer.

Time frame: up to 3 hours

Population: Excluded subjects are shown below:~20 subjects: no valid blood reference results 73 subjects: time between the first valid SpHb reading and the venous blood draw exceeded 10 minutes.~32 subjects: low Perfusion Index quality. 3 subjects: low signal stability 26 subjects: low SpHb confidence 18 subjects : no SpHb result displayed. 21 subjects: user error~1 subject: pregnant

ArmMeasureValue (NUMBER)
Test GroupSensitivity of SpHb Detection of Anemia.60.77 percent of true positives
Primary

SpCO Detection of Carbon Monoxide Poisoning (COP)

Diagnostics performance of SpCO for detecting COP measured by sensitivity and specificity compared to COHb.

Time frame: up to 3 hours

Population: Out of the 600 subjects that were analyzed from all that were enrolled, only 26 subjects met the criteria for carbon monoxide poisoning.

ArmMeasureGroupValue (NUMBER)
Test GroupSpCO Detection of Carbon Monoxide Poisoning (COP)Sensitivity of COP Detection73.08 percentage
Test GroupSpCO Detection of Carbon Monoxide Poisoning (COP)Specificity of COP Detection82.75 percentage
Primary

Specificity of SpHb in Detecting Anemia.

Specificity in detecting true non-anemic subjects as determined by co-oximeter reference analyzer.

Time frame: up to 3 hours

Population: Excluded subjects are shown below:~20 subjects: no valid blood reference results 73 subjects: time between the first valid SpHb reading and the venous blood draw exceeded 10 minutes.~32 subjects: low Perfusion Index quality. 3 subjects: low signal stability 26 subjects: low SpHb confidence 18 subjects : no SpHb result displayed. 21 subjects: user error~1 subject: pregnant

ArmMeasureValue (NUMBER)
Test GroupSpecificity of SpHb in Detecting Anemia.81.00 percentage of true negative
Primary

SpHb Utility for Screening Anemia

Establish SpHb threshold that predicts the clinical outcome for acute treatment of anemia

Time frame: up to 3 hours

Population: The number of subjects requirement defined by the study protocol were not met in this study, thus the threshold that predicts the outcome of acute treatment of anemia cannot be determined nor validated.

Primary

Utility of SpCO as a Screening Tool for Carbon Monoxide Poisoning

Surveying healthcare providers whether SpCO screening lead to identification of occult toxicity

Time frame: up to 3 hours

Population: Clinician survey were not conducted or collected to perform data analysis.