Skip to content

Bone Myoregulation Reflex & Presynaptic Ia Inhibition

Effects of Cooling of Ankle on Bone Myoregulation Reflex Response and Presynaptic Ia Inhibition Level

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03016286
Enrollment
10
Registered
2017-01-10
Start date
2017-11-01
Completion date
2018-04-17
Last updated
2017-07-13

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Effects of Vibration

Keywords

Whole body vibration, Bone myoregulation reflex, H-reflex

Brief summary

Hypotheses of this study are 1. Bone myoregulation reflex (BMR) inhibits presynaptically H-reflex during whole-body vibration (WBV) 2. Cooling of ankle abolishes the inhibitor effect of BMR on soleus H-reflex Aim of this study is to test these hypotheses. Methods: This study will be conducted on 10 healthy young adult males. WBV will be applied at 35 Hz frequencies with 2 mm amplitudes. Cold pack will be applied the right ankle for 20 minutes. The right soleus T-reflex will be recorded before WBV, during WBV, during cooling of the right ankle, and during WBV respectively.

Detailed description

Hypotheses of this study are 1. Bone myoregulation reflex (BMR) inhibits presynaptically T-reflex during whole-body vibration (WBV) 2. Cooling of ankle abolishes the inhibitor effect of BMR on soleus T-reflex Aim of this study is to test these hypotheses. Methods: Participants: Ten young, healthy and right hand dominant male adult volunteers will be included in this study. Procedure: Prior to the induction of WBV, control T-reflex recordings will be elicited and then the participants will complete a 15-s trial WBV protocol to familiarize themselves with the procedure. Following the control T-reflex recordings, the trial protocol and a 15-s rest, the participants will receive one session WBV. T-reflex will be recorded during WBV. Then, cold pack will be applied to the right ankle for 20 minutes. T-reflex will be recorded during the cooling of the ankle. Then, the participants will receive one session WBV, again. T-reflex will be recorded during WBV. A light (2.9 gr.) triaxial (x, y and z-axis) accelerometer (LIS344ALH, ECOPACK®) will be taped on the right Achilles tendon so that the z-axis will be perpendicular with the direction of the tendon (Achilles accelerometer). A custom-made reflex hammer will be used to tap the right Achilles tendon just caudal to the accelerometer. The intensity of tapping will be about 19.6 N WBV frequencies of 35 Hz will be delivered for 60 s. The vibration plate of WBV device (Power-Plate®Pro5, PowerPlate® International, Ltd. London, UK) oscillates with a linear movement upward and downward. The participants will be barefooted and stand directly on the vibration platform. The surface electromyography (SEMG) data will be obtained while the participants stand upright on the vibration platform with the knees in extension. The Ag/AgCl electrodes (KENDALL®Covidien) with a disc radius of 10 mm will be placed 20 mm apart on the right soleus muscle belly on shaved skin in accordance with the recommendations of the Surface ElectroMyoGraphy for the Non-Invasive Assessment of Muscles (SENIAM) project . The recordings of both T-reflex and WBV-IMR will be acquired using SEMG. SEMG data will be recorded using a PowerLAB® data acquisition system (ADInstruments, Oxford, United Kingdom) and the data will be analyzed offline using the LabChart7® (ver 7.3.7, ADInstruments, Oxford, United Kingdom) software. Precautions for voluntary muscle contractions and motion artifacts: 1. the participants will be asked to use the handles of the WBV device to secure their balance. The sense of balance may impair during WBV. Therefore muscles may be activated to restore balance during WBV, 2. before WBV trials, participants will be asked to relax and not to make voluntary contractions in their lower extremity muscles. 3. a trial protocol will be applied to familiarize vibration, 4. all cables will be carefully taped to the skin to minimize motion artifacts, 5. all EMG recordings will be filtered to avoid WBV induced movement artifacts using a band pass filter from 60 to 500 Hz.

Interventions

OTHERvibration

Whole body vibration at 25Hz frequency

Sponsors

Bagcilar Training and Research Hospital
Lead SponsorOTHER_GOV

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
BASIC_SCIENCE
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
20 Years to 45 Years
Healthy volunteers
Yes

Inclusion criteria

* Healthy male * Right-handed men

Exclusion criteria

* Bone, muscle/tendon, joint, vascular, dermatologic diseases in lower extremities and spine * Medication that could affect the musculoskeletal system * Postural abnormalities (scoliosis, kyphosis, etc) * Systemic diseases

Design outcomes

Primary

MeasureTime frame
Presynaptic Ia inhibition level1 month

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026