Evaluation of the Safety, Effectiveness & Usability of the XACT Robotic System for Image Guided Percutaneous Procedures

Evaluation of the Safety, Effectiveness & Usability of the XACT Robotic System for Image Guided Percutaneous Procedures

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03008603
Enrollment
60
Registered
2017-01-02
Start date
2018-09-04
Completion date
2021-02-16
Last updated
2021-09-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

CT-guided Minimally Invasive Procedures e.g., Biopsies

Keywords

CT-guided minimally invasive procedures, Robot

Brief summary

This is a prospective, single-arm study is to evaluate the safety, effectiveness and usability of the XACT device. Subjects undergoing CT-guided, minimally invasive percutaneous procedures in the interventional radiology suite, e.g., core biopsy, will participate in the summary. Clinical accuracy will be the primary efficacy endpoint. Usability and safety will also be evaluated.

Detailed description

This is a prospective, single-arm study is to evaluate the safety, effectiveness and usability of the XACT device. The study will be approved by the Institutional Review Board (IRB) at each of the participating centers prior to patient enrollment. Subjects undergoing CT-guided, minimally invasive percutaneous procedures in the interventional radiology suite, e.g., core biopsy, fine needle aspiration (FNA), tumor ablation, etc., and willing to sign an informed consent document will be screened for compliance with the study inclusion and exclusion criteria. A total of thirty (85) subjects will be enrolled in the study at 5 medical centers. The intention is to recruit subjects, which will cover a variety of CT-guided interventional procedures and a variety of different procedural tools that may be used with the device. Investigators will screen patients based on the inclusion/exclusion criteria described below and the subjects' demographic, general medical history, medical condition/indication, coagulation factors, concomitant medications and vital signs will be obtained. Clinical accuracy will be the primary efficacy endpoint and is defined as the ability to place the instrument or procedural tool at a location suitable for the planned intervention. The investigator will review the final instrument position on the post-placement CT images to determine if the pre-operative planned target was reached. This information will be used to calculate success rate. Additionally, the usability of the XACT device will be evaluated using a rating scale by assessing the ease of device setup, device operation, pre-operative planning, robot positioning, guiding and needle advancement. The total time of the procedure will be recorded, as will the number of CT scans performed and the radiation dose (DLP and CTDI). The distance from the tip of the needle/tool to the target, once the XACT robot reaches the pre-defined target will be measured in order to determine system accuracy in quantitative terms using the system tools.

Interventions

The XACT device is a real-time, CT image guided, 3-dimensional robotic system. The XACT device is intended for use as an image guided positioning and steering system for insertion of clinical tools, such as biopsy needles, ablation needles, etc., during minimally invasive percutaneous procedures. The system is defined to guide (i.e., position and steer) the tool according to a predefined trajectory following a registration process between the device's coordinate system and real-time CT images.

Sponsors

Xact Robotics Ltd.
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Men and women over 18 years of age * Subjects undergoing CT-guided, minimally invasive percutaneous procedures in the interventional radiology suite, e.g., core biopsy, fine needle aspiration (FNA), tumor ablation, etc. * Subject is capable and willing to provide informed consent. * Subject is capable and willing to adhere to the study procedures

Exclusion criteria

* Subjects in whom the target is written 1 cm of a major blood vessel or major nerve. * Subject with lesions in the central and peripheral nervous system and the spine. * Subject with significant coagulopathy * Subjects with a preexisting conditions, which, in the opinion of the investigator, may interfere with the conduct of the study * Subjects with an unstable medical condition, e.g. unstable hypertension, unstable cardiac disease, etc. * Subjects who are uncooperative or cannot follow instructions * Subjects with a mental state that may preclude completion of the study procedure * Female subjects who are pregnant or nursing

Design outcomes

Primary

MeasureTime frameDescription
The primary endpoint of the study is to evaluate the clinical accuracy of the XACT system.End of procedureClinical accuracy of the study will be determined by the ability of the XACT system to reach the pre-defined target in each procedure.

Secondary

MeasureTime frameDescription
The secondary endpoint of the study is to evaluate the usability of the XACT system under actual use clinical conditions.End of procedureusability of the XACT device will be evaluated using a rating scale by assessing the ease of device setup, device operation, pre-operative planning, robot positioning, guiding and needle advancement.

Other

MeasureTime frameDescription
Incidence of Treatment-Emergent Adverse EventsEnd of procedureSafety of the XACT device will also be evaluated by reporting the incidence, severity and frequency of all Adverse Events (AE), related and unrelated to the device treatment.

Countries

Israel, United States

Outcome results

None listed