Effectiveness and Safety Study of the Percutaneous Optical Fibre Glucose Sensor (FiberSense)

Effectiveness and Safety Study of the Percutaneous Optical Fibre Glucose Sensor (FiberSense) for Home Use in Diabetic and Prediabetic Individuals

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03008239
Enrollment
26
Registered
2017-01-02
Start date
2017-11-14
Completion date
2019-10-31
Last updated
2019-09-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus

Brief summary

This study evaluates the performance and safety of the fluorescence based fibre optic glucose sensor for home usage.24 subjects will take part in the study, including 4 pre-diabetic subjects, 8 Type I diabetic patients, 8 Type II diabetic patients and 4 diabetic patients who require continuous ambulatory peritoneal dialysis (CAPD). Type 1, Type 2 and prediabetic subjects will wear one FiberSense sensor, randomly allocated to either the upper arm (50%) or abdomen (50%) for 28 days. In addition, these subjects will wear a Dexcom sensor on the other side of the abdomen for 7 days in one of the four study weeks. In all 4 CAPD subjects, one FiberSense sensor will be placed in the upper arm for 28 days. No additional comparator sensor will be placed in CAPD subjects.

Detailed description

The FiberSense system is a glucose-monitoring device indicated for continually recording interstitial fluid glucose levels in patients ages 18 and older with insulin dependent diabetes mellitus for the purpose of improving diabetes management. The System is intended for use by patients at home and in health care facilities. The FiberSense system is indicated for use as an adjunctive device to complement, not replace, information obtained from standard home glucose monitoring devices. The FiberSense system aids in the detection of episodes of hyperglycemia and hypoglycemia, facilitating both acute and long-term therapy adjustments, which may minimize these excursions.

Interventions

DEVICEFiberSense sensor

The FiberSense system is a glucose-monitoring device indicated for continually recording interstitial fluid glucose levels in patients ages 18 and older with insulin dependent diabetes mellitus for the purpose of improving diabetes management.

DEVICEDexcom Sensor

Dexcom is a continuous glucose monitoring (CGM) system. The display device shows the glucose readings and the trend.

Sponsors

Lee's Pharmaceutical Limited
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 70 Years
Healthy volunteers
No

Inclusion criteria

* Type I or II diabetes mellitus requiring insulin in the management of glucose control for at least one year prior to enrollment or diabetes on continuous ambulatory peritoneal dialysis or prediabetic individuals with impaired fasting glucose or impaired glucose tolerance by OGTT * Male or female age ≥ 18 years old and ≤ 70 year old. * Women who are not pregnant, lactating or planning a pregnancy during their participation in the clinical study. * Willingness, ability and commitment to comply with the testing, procedure and follow-up outlined in this protocol including (but not limited to) frequency of clinic visits and use of pre-specified glucose monitoring devices. * Willingness to abstain from swimming during their participation in the measurement phase. * In the opinion of the investigator, absence of any physical limitations, addictive diseases, or underlying medical conditions (including mental health) that may preclude the patient from being a good study candidate. * Written informed consent to participate in the study provided by the patient.

Exclusion criteria

* Poorly controlled diabetes mellitus with HbA1C \>11%. * Currently pregnant, as demonstrated by a positive pregnancy test at screening and on Day00 . * Impaired hepatic function measured as alanine aminotransferase (ALT) or aspartate aminotransferase (AST) ≥ three times the upper reference limit. * Any active acute or chronic disease or condition that, in the opinion of the investigator, might interfere with the performance of this study. * Any active acute or chronic infectious disease that, in the opinion of the investigator, would pose an excessive risk to study staff. * Current use or recent exposure to any medication that in the opinion of the investigator could have an influence on the patient's ability to participate in this study or on the performance of the test device. * Extensive skin changes/diseases that preclude wearing the required number of devices on normal skin at the proposed application sites (e.g., extensive psoriasis, recent burns or severe sunburn, extensive eczema, extensive scarring, extensive tattoos, dermatitis herpetiformis). * Have a known allergy to medical-grade adhesives, or known hypersensitivity to any of the products used in the study. * Known current or recent alcohol or drug abuse * Blood donation of more than 500 ml within the last three months * Currently participating in another investigational study protocol where the testing or results may interfere with study compliance, diagnostic results, or data collection. * Has a MRI scan, CT scan, or diathermy scheduled during the proposed study participation. * An identified protected vulnerable patient (including but not limited to those in detention, or a prisoner). * Women of reproductive potential who are unwilling to adopt contraceptive measures during the study period

Design outcomes

Primary

MeasureTime frameDescription
Blood glucose28 daysThe primary endpoint is the proportion of FiberSense readings within ≤15% of the reference (YSI) reading for blood glucose levels \>100 mg/dl, and the proportion of FiberSense readings within ≤15 mg/dl of the YSI reading for blood glucose levels ≤100 mg/dl, for paired samples taken during the in-clinic sessions.
Adverse Events reporting35 days

Secondary

MeasureTime frameDescription
Mean Absolute Relative Differences from YSI28 days
Median Absolute Relative Differences from YSI28 days
Hypoglycemia detection rates28 days
Hyperglycemia detection rates28 days
Accuracy of glucose rate of change of FiberSense sensor compared to glucose rate of change of YSI28 days
Lag time between FiberSense readings and YSI results during induced glucose excursions28 days
Mean Relatives Differences from YSI28 days
Calibration stability28 days
Sensor stability28 days
Sensor life28 days
User satisfaction questionnaire score28 days
Blood maltose concentrations28 daysMeasured in CAPD subjects during the V1 in-clinic session
Agreement and accuracy relative to SMBG readings (same model to be used by all subjects)28 days
Median Relatives Differences from YSI28 days

Countries

Hong Kong

Outcome results

None listed