Skip to content

Safety and Efficacy of SYM-SV/DS-002 in Patients With Severe Aortic Stenosis

Safety and Efficacy of SYM-SV/DS-002 in Patients With Severe Aortic Stenosis

Status
Terminated
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03004599
Enrollment
11
Registered
2016-12-29
Start date
2016-11-30
Completion date
2017-10-31
Last updated
2017-11-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Severe Aortic Stenosis

Keywords

Valvular Heart Disease, Critical Aortic Stenosis, Severe Aortic Stenosis, High Risk, Aortic Valve Replacement, Cardiovascular Disease, Aortic Stenosis, Heart Valve Therapy, Transcatheter, Transfemoral, TAVI, TAVR, ACURATE neo™ Aortic Bioprosthesis, ACURATE TF™ Transfemoral Delivery System

Brief summary

Safety and Efficacy of SYM-SV/DS-002 in Patients with Severe Aortic Stenosis

Detailed description

To evaluate the safety and efficacy of Transfemoral Transcatheter Aortic Valve Implantation using SYM-SV-002 Aortic Bioprosthesis and SYM-DS-002 Transfemoral Delivery System in patients presenting with symptomatic severe aortic stenosis and with difficulty to safely undergo conventional surgical aortic valve replacement (AVR)

Interventions

DEVICESYM-SV-002 Aortic Bioprosthesis and SYM-DS-002 Transfemoral Delivery System

Transcatheter Aortic Valve Implantation via Transfemoral Approach

Sponsors

Medico's Hirata Inc.
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

1. At least one cardiologist and one cardiac surgeon agree that it is difficult for the patient to receive a surgical procedure due to medical factors such that the subject has various comorbidities and he/she is more likely to die or suffer from severe diseases than to have significant improvements by a surgical procedure. 2. Subject has senile degenerative aortic valve stenosis with: * mean gradient \> 40 mmHg, or maximum jet velocity greater than 4.0 m/sec by either resting or dobutamine stress echocardiogram, or simultaneous pressure recordings at cardiac catheterization * AND an initial aortic valve area of ≤ 0.8 cm2 (or aortic valve area index ≤ 0.5 cm2/m2) by resting echocardiogram or simultaneous pressure recordings at cardiac catheterization 3. Subject is symptomatic from his/her aortic valve stenosis (AS), as demonstrated by New York Heart Association (NYHA) Functional Class II or greater. 4. The subject has been informed of the nature of this trial, agrees to its provisions and has provided written informed consent as approved by the IRB of the respective clinical site. 5. The subject or the subject's legal representative agrees to visit the site where he/she receives index procedure for all required post-procedure follow-ups.

Exclusion criteria

1. Evidence of an acute myocardial infarction ≤ 30 days (The procedure day is counted as day 0.) before the implant procedure 2. Any percutaneous coronary or peripheral interventional procedures, including placements of bare metal stents are performed within 30 days prior to the implant procedure, or any drug eluting stents are placed within 6 months (One month is counted as 30 days.) prior to the implant procedure 3. Untreated clinically significant coronary artery disease (CAD) requiring revascularization 4. Blood dyscrasias as defined: leukopenia (WBC \< 1,000/mm3), thrombocytopenia (platelet count \<50,000 cells/mm3), history of bleeding diathesis or coagulopathy 5. Cardiogenic shock manifested by low cardiac output, vasopressor dependence, or mechanical hemodynamic support 6. Need for emergency surgery for any reason 7. Severe ventricular dysfunction with left ventricular ejection fraction (LVEF) \< 20% as measured by resting echocardiogram 8. Cerebrovascular accident (CVA) or transient ischemic attack (TIA) within 6 months prior to the implant procedure (except mild TIA related to aortic stenosis) 9. End stage renal disease requiring chronic dialysis or serum creatinine \> 3.0 mg/dL 10. Active Gastrointestinal (GI) bleeding within 3 months prior to the implant procedure 11. A known hypersensitivity or contraindication to any of the following which cannot be adequately pre-medicated: * Aspirin * Heparin (HIT/HITTS) * Nitinol (titanium or nickel) * P2Y12 inhibitors (such as Ticlopidine etc.) * Contrast media 12. Ongoing sepsis, including active endocarditis 13. Subject refuses a blood transfusion 14. Life expectancy \< 12 months due to associated non-cardiac comorbid conditions 15. Other medical, social, or psychological conditions that in the opinion of a principal investigator or sub-investigator precludes the subject from appropriate consent 16. Severe dementia (unable to provide informed consent for the treatment/procedure, unable to live an independent life outside of a chronic care facility, or expected to be fundamentally unable to undergo rehabilitation after the procedure, or unable to come to the site for follow-up visits) 17. Currently participating in other trials of investigational drugs or other investigational devices 18. Native aortic annulus size \< 21 mm or \> 27 mm per the baseline diagnostic imaging 19. Pre-existing prosthetic heart valve and / or prosthetic ring in any position 20. Mixed aortic valve disease (aortic stenosis and predominant aortic regurgitation (3-4+)) 21. Moderate to severe (3-4+) or severe (4+) mitral regurgitation or severe (4+) tricuspid regurgitation 22. Moderate to severe mitral stenosis 23. Hypertrophic obstructive cardiomyopathy 24. New or untreated echocardiographic evidence of intracardiac mass, thrombus or vegetation 25. Congenital bicuspid or unicuspid valve verified by echocardiograph 26. Extreme eccentric calcification of the native aortic valve 27. Transesophageal echocardiogram (TEE) is contraindicated. 28. Scheduled surgical or percutaneous procedure to be performed prior to 1-month visit post-implant procedure 29. Hepatic failure (Child C or more) 30. Aortic or peripheral condition NOT appropriate for transfemoral implant due to the size, disease and degree of calcification or tortuosity of the aorta or ilio-femoral arteries 31. Thoracic or abdominal aortic aneurysm 32. Woman who is pregnant, breastfeeding or willing to become pregnant

Design outcomes

Primary

MeasureTime frame
Survival rateat 12 months post-procedure

Secondary

MeasureTime frameDescription
Occurrence rates of individual MACCE componentsat 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedureIndividual MACCE components include: * All Cause Mortality * Myocardial infarction (MI) * All Stroke * Reintervention
Occurrence rates of Major Adverse Events (MAEs)at 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedureMAEs include: * MACCE * Acute Kidney Injury (AKI) * Cardiac Tamponade * Prosthetic Valve Dysfunction (PVD) * Cardiogenic Shock * Prosthetic Valve Endocarditis * Life-Threatening, Disabling or Major Bleeding * Major Vascular Complications * Cardiac Perforation * Device Migration/Valve Embolism
Occurrence rate of conduction disturbance requiring Permanent Pacemaker Implantation(PPI)at 1 month, 6 month, 12 months, 2 years, 3 years, 4 years and 5 years post-procedure
Change in NYHA class from baselineat 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedure
Change in distance walked during 6-Minute Walk Test (6MWT) from baselineat 1 month and 12 month post-procedure
Occurrence rates of MACCEat 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedureMACCE is defined as a composite of: * All Cause Mortality * Myocardial infarction (MI) * All Stroke * Reintervention
Echocardiographic assessment of valve performanceat 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedureEffective Orifice Area Index (EOAI)
Device successNumber of days from admission to discharge (estimated to be at 7 days post-procedure on average)Device success is defined as that all of the following are achieved: * Successful vascular access * Successful delivery and deployment of the device * Successful retrieval of the delivery system * Correct position of the device in the proper anatomical location (placement in the aortic annulus with no impedance on device function) * Intended performance of the prosthetic heart valve is confirmed by echocardiography (defined as below): * No Patient-Prosthesis Mismatch (PPM) (EOAI \>0.85cm2/m2) * And mean aortic valve gradient \< 20 mmHg or peak velocity \< 3 m/sec, * And no moderate or severe prosthetic valve regurgitation * Only one valve implanted in the proper anatomical location
Procedural successNumber of days from admission to discharge (estimated to be at 7 days post-procedure on average)Procedural success is defined as that all of the following are achieved: * Achievement of the device success * Absence of in-hospital MACCE
Occurrence rate of Prosthetic Valve Dysfunction (PVD)at 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedureProsthetic Valve Dysfunction (PVD) is defined as: * Aortic regurgitation (AR) reported as moderate or severe by echocardiography assessments * Significant aortic stenosis (AS) which meets one or more of the following by echocardiography assessments: * Peak velocity \> 4 m/s * Mean gradient \> 35 mmHg * Effective Orifice Area (EOA) \< 0.8 cm2 * TVIV1/TVIV2 \< 0.25
Occurrence rate of clinical endpoints per VARC 2at 1 month post-procedure* Mortality * Stroke * Myocardial infarction (MI) * Bleeding complications * Acute kidney injury (AKI) * Vascular complications * Conduction disturbances and arrhythmia * Other TAVI-related complications
Change in QOL from baselineat 1 month, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years post-procedureKansas City Cardiomyopathy Questionnaire (KCCQ)

Countries

Japan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026