Comparing the Outcomes of Incisions Made by Colorado® Microdissection Needle

Comparing the Outcomes Of Incisions Made By Colorado® Microdissection Needle, Electrosurgery Tip And Surgical Blade During Periodontal Surgery

Status
Completed
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03003624
Enrollment
30
Registered
2016-12-28
Start date
2015-03-31
Completion date
2016-08-31
Last updated
2016-12-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Periodontitis

Keywords

Incisions, microdissection needle

Brief summary

The aim of the present study was to compare the outcomes of incisions made by Colorado® microdissection needle, electrosurgery tip and surgical blade during periodontal surgery.

Detailed description

Commercially, many microdissection needle systems are available, such as Stryker Colorado® microdissection needle (CMN) (Stryker-Leibinger, Freiburg, Germany) and optimicro™ microdissection needles. Colorado® microdissection needle (CMN) combine the advantages of scalpel and electrosurgery. CMN® was introduced into clinical practice in 1997, with a wide array of applications in the field of Ophthalmology, Neurosurgery, and others. The primary feature of the Colorado® microdissection needle is the ultra-sharp tungsten tip that delivers the wave-form from the electrosurgery generator to a very small spot. This allows the use of extremely low wattages, resulting in less tissue necrosis, precision cutting and cautery, and less post-operative pain. The instrument tip is a delicately machined, insulated tungsten diathermy needle that is compatible with any standard cautery hand piece. Tungsten, with its extremely high melting point (\>3400°C) provides a heat resistant tip that maintains sharpness compared to stainless steel tips that dull rapidly.

Interventions

DEVICEColorado® microdissection needle

The primary feature of the Colorado® microdissection needle is the ultra-sharp tungsten tip that delivers the wave-form from the electrosurgery generator to a very small spot. This allows the use of extremely low wattages, resulting in less tissue necrosis, precision cutting and cautery, and less post-operative pain.

DEVICECautery tip

Studies have shown that, heat generated by electrosurgical devices are influenced by factors like duration of contact between tissue and electrode tip, current intensity, electro section waveform and the electrode tip size. A larger tip causes more tissue damage, increased operating power and more amount of lateral heat production. This led to the development of microdissection needle with fine electrode tip and efficient power usage. The use of microdissection needles does not have any significant difference in wound healing or pain when compared with scalpel.

DEVICEBP blade

Studies have shown that, heat generated by electrosurgical devices are influenced by factors like duration of contact between tissue and electrode tip, current intensity, electro section waveform and the electrode tip size. A larger tip causes more tissue damage, increased operating power and more amount of lateral heat production. This led to the development of microdissection needle with fine electrode tip and efficient power usage. The use of microdissection needles does not have any significant difference in wound healing or pain when compared with scalpel.

Sponsors

SVS Institute of Dental Sciences
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Caregiver, Investigator)

Eligibility

Sex/Gender
ALL
Age
25 Years to 55 Years
Healthy volunteers
Yes

Inclusion criteria

* Systemically healthy individuals within the age group of 25-45 years having at least 20 teeth remaining in the mouth of which at least 4 teeth in each quadrant requiring periodontal surgery, patients with periodontal pockets with ≥5 mm in depth suitable for modified Widman flap were included in the study.

Exclusion criteria

* Patients who underwent periodontal therapy in the past 6 months, medically compromised patients, patients with poorly shielded cardiac pacemakers were excluded from the study.

Design outcomes

Primary

MeasureTime frameDescription
Quantity of blood loss in mlImmediate postoperative volumeQuantity of blood loss by swab weighing method.
PPD in mmBaseline to 180 daysProbing pocket depths (PPD) were recorded using a University of North Carolina no. 15 (UNC -15) color-coded periodontal probe at baseline, 120 and 180 days after surgery.
Changes in dimensions of interdental papilla in mmBaseline to 180 daysChanges in dimensions of interdental papilla using a periodontal probe.

Secondary

MeasureTime frameDescription
Assessment of postoperative pain:1 day, 7 & 15 daysPostoperative pain was assessed by using visual analogue scale (VAS) which was recorded 1 day, 7 & 15 days after surgery. The visual analogue scale (VAS) consists of a line, usually 10 cm long, whose ends are labelled as the extremes ('no pain' and 'severe pain'). The patients were asked to mark on the line which indicated their pain intensity.
Assessment of wound healing:1 day, 7 & 15 daysWound healing was recorded using Early wound healing index (EHI).

Countries

India