Skip to content

PARTNER 3 Trial - Aortic Valve-in-Valve

A Prospective, Single-Arm, Multicenter Study to Investigate the Safety and Effectiveness of SAPIEN 3/SAPIEN 3 Ultra Transcatheter Heart Valve Implantation in Patients With a Failing Aortic Bioprosthetic Valve

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT03003299
Enrollment
125
Registered
2016-12-28
Start date
2017-01-05
Completion date
2038-04-30
Last updated
2024-05-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis, Aortic Stenosis, Severe

Keywords

SAPIEN 3, PARTNER 3, cardiovascular disease, heart disease, aortic stenosis, SAVR, TAVR, failing surgical valve, failing bioprosthetic valve, failing valve, SAPIEN 3 Ultra

Brief summary

This study will assess the safety and effectiveness of the SAPIEN 3/SAPIEN 3 Ultra transcatheter heart valve (THV) in patients with a failing aortic bioprosthetic valve.

Detailed description

This is a prospective, single-arm, multicenter study.

Interventions

DEVICEEdwards SAPIEN 3/SAPIEN 3 Ultra THV

Edwards SAPIEN 3/SAPIEN 3 Ultra THV system with the associated delivery systems.

Sponsors

Edwards Lifesciences
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

1. Failing surgical or transcatheter bioprosthetic valve in the aortic position demonstrating ≥ moderate stenosis and/or ≥ moderate insufficiency. 2. Bioprosthetic valve with a true internal diameter (True ID) of 18.5 mm to 28.5 mm. 3. NYHA Functional Class ≥ II. 4. Heart Team agrees the patient is low to intermediate risk. 5. Heart Team agrees valve implantation will likely benefit the patient. 6. The study patient has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.

Exclusion criteria

1. Surgical or transcatheter valve in the mitral position (mitral rings are not an exclusion) 2. Severe regurgitation (\> 3+) or stenosis of any other valve 3. Failing valve has moderate or severe paravalvular regurgitation 4. Failing valve is unstable, rocking, or not structurally intact 5. Increased risk of coronary obstruction by prosthetic leaflets of the failing valve. 6. Increased risk of embolization of THV 7. Known bioprosthetic valve with residual mean gradient \> 20 mmHg at the end of the index procedure for implantation of the original valve 8. Iliofemoral vessel characteristics that would preclude safe placement of the introducer sheath (Transfemoral) 9. Anatomical characteristics that would preclude safe access to the ascending aorta (Transaortic) 10. Anatomical characteristics that would preclude safe access to the apex (Transapical) 11. Evidence of an acute myocardial infarction ≤ 30 days before enrollment 12. Any therapeutic invasive cardiac procedure resulting in a permanent implant that is performed within 30 days prior to the index procedure. Implantation of a permanent pacemaker or implantable cardioverter defibrillator is not considered an exclusion. 13. Patients with planned concomitant surgical or transcatheter ablation for Atrial Fibrillation 14. Leukopenia, anemia, thrombocytopenia, history of bleeding diathesis or coagulopathy or hypercoagulable states 15. Untreated clinically significant coronary artery disease requiring revascularization 16. Hemodynamic or respiratory instability requiring inotropic support, mechanical ventilation, or mechanical heart assistance within 30 days of enrollment 17. Emergency interventional/surgical procedures within 30 days prior to the procedure 18. Any planned surgical, percutaneous coronary, or peripheral procedure to be performed within the 30-day follow-up from the procedure 19. Hypertrophic cardiomyopathy with obstruction 20. LVEF \< 30% 21. Cardiac imaging evidence of intracardiac mass, thrombus, or vegetation 22. Inability to tolerate or condition precluding treatment with antithrombotic/anticoagulation therapy during or after the valve implant procedure 23. Absolute contraindications or allergy to iodinated contrast that cannot be adequately treated with premedication 24. Stroke or transient ischemic attack within 90 days of enrollment 25. Symptomatic carotid or vertebral artery disease or successful treatment of carotid stenosis within 30 days of enrollment 26. Renal insufficiency and/or renal replacement therapy at the time of screening 27. Active bacterial endocarditis within 180 days of the procedure 28. Patient refuses blood products 29. Estimated life expectancy \< 24 months 30. Positive urine or serum pregnancy test in female subjects of childbearing potential 31. Currently participating in an investigational drug or another device study

Design outcomes

Primary

MeasureTime frameDescription
Safety and Effectiveness - Non-hierarchical composite of all-cause mortality and stroke1 yearNumber of patients that died and/or had a stroke

Secondary

MeasureTime frameDescription
Mean gradient30 daysMeasures the mean aortic pressure gradient from the measured velocity. Units used are mmHg.
Peak gradient30 daysMeasures the peak aortic pressure gradient from the measured velocity. Units used are mmHg.
Kansas City Cardiomyopathy Questionnaire (KCCQ)30 daysChange from baseline in KCCQ. The KCCQ is a 23-item self-administered questionnaire developed to independently measure the patient's perception of their health status, which includes heart failure symptoms, impact on physical and social function, and how their heart failure impacts their quality of life.
New York Heart Association (NYHA) Classification30 daysChange from baseline in NYHA. NYHA is a functional classification of heart failure based on how much a patient is limited during physical activity. The rating ranges from I - IV, with the lowest (I) as no limitations and the highest (IV) unable to carry on any physical activity without discomfort.
Six-Minute Walk Test (6MWT)30 daysChange from baseline in 6MWT. The 6-Minute Walk Test is a sub-maximal exercise test used to assess aerobic capacity and endurance. The distance covered over a time of 6 minutes is used as the outcome by which to compare changes in performance capacity.

Countries

Canada, United States

Contacts

Primary ContactEdwards THV Clinical Affairs
THV_CT.gov@Edwards.com(949) 250-2500

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026