Skip to content

Assessing Deformable Image Registration in the Lung Using Hyperpolarized-gas MRI

Assessing Deformable Image Registration in the Lung Using Hyperpolarized-gas

Status
UNKNOWN
Phases
Phase 1
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02995590
Enrollment
24
Registered
2016-12-16
Start date
2016-07-01
Completion date
2021-12-15
Last updated
2020-11-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Healthy Volunteers

Brief summary

Recently, the investigators have demonstrated a novel hyperpolarized helium tagging Magnetic Resonance Image (MRI) technique that is capable of directly, in vivo, and non-invasively measuring physiological lung deformation on a regional basis. This unique imaging technique holds great promise for assessing, validating, and improving the use of Deformable image Registration (DIR) algorithms in the lung. Our long term aim is to apply hyperpolarized gas tagging MRI to study lung biomechanics, develop more physiologically sound DIR algorithms for the lungs, and eventually improve radiotherapy of lung cancer. The overall aim of this application is to optimize the hyperpolarized helium tagging MRI technology and establish its usefulness for DIR assessment. Our first objective is to develop and optimize a methodology based on 3 Dimensional (3D) hyperpolarized helium tagging MRI of healthy subjects, for directly measuring lung deformation between inhalation and exhalation. Our second objective is to develop physiologically sound digital thorax phantoms based on helium-3 tagging MRI of healthy subjects and demonstrate their use for DIR assessment in the lung. These phantoms will be used to evaluate a range different DIR algorithms, by comparing the errors between the DIR-derived deformation vector fields and the ground truth represented in the digital phantom. Successful completion of these aims will yield a novel methodology for DIR assessment in the lung for radiotherapy.

Detailed description

The purpose of this study is to develop new ways to make medical images of the lungs and liver of adults using a technique called four-dimensional magnetic resonance imaging (4D-MRI). This technique produces three-dimensional movies of the inside of the chest and abdomen while the patient is breathing. (The fourth dimension is time!) This new way of medical imaging is being developed to help cancer patients undergoing radiation therapy. Radiation therapy is used to treat cancerous tumors. For radiation therapy to be effective, the precise size, shape, and location of the tumor within the body must be known. A particular difficulty for radiation treatment of lung and liver cancer is that the tumor moves during treatment because the patient is breathing. Therefore, tumor motion must also be incorporated into the treatment plan. This study aims to improve radiation treatment planning through better targeting and dose estimation based on 4D-MRI. Before this new imaging method can be used for radiation treatment planning, it must be tested in living, breathing volunteers. You are being asked to take part in a research study because you are a cancer patient or a healthy volunteer. You do not have to take part in this study. You should only agree to take part in this study after reading this consent form and discussing it with the study team. You may also discuss this with your family, friends, health care providers or others before you make a decision. Though you may not be directly helped by being in this study, the information gained by doing this study may help others in the future. You might not want to take part in this study because of the temporary risk of discomfort during the time the subject is asked to lie still in the confined space of the MRI scanner. This discomfort may include claustrophobia (fear of being in a small space), feelings of warmth, muscle twitching due to excited nerves, and exposure to loud thumping noises produced by the MR scanner. If you are pregnant or think you may be pregnant, if would not be safe for you to be in this study.

Interventions

DRUGHyperpolarized He3

Hyperpolarized Helium can be used as a Contrast Agent for Lung Images using MRI.

Sponsors

University of Virginia
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 64 Years
Healthy volunteers
Yes

Inclusion criteria

* All subjects must be willing to participate and undergo the procedure, and be manageable as out-patients. * Normal Subjects: Currently feeling well without respiratory symptoms. * No history of lung disease. * Never personally smoked (defined as less 100 cigarettes in their lifetime). -Secondhand smoke exposure is not an exclusion criterion.

Exclusion criteria

* Blood oxygen saturation of less than 92% as measured by pulse oximetry on the day of imaging. * FEV1 percent predicted less than 80%. * Pregnancy or lactation. * Claustrophobia, inner ear implants, aneurysm or other surgical clips, metal foreign bodies in eye, pacemaker or other contraindication to MR scanning. Subjects with any implanted device that cannot be verified as MRI compliant will be excluded. * Chest circumference greater than that of the xenon MR and/or helium coil. The circumference of the coil is approximately 42 inches. * History of congenital cardiac disease, chronic renal failure, or cirrhosis. * Inability to understand simple instructions or to hold still for approximately 10 seconds. * History of respiratory infection within 2 weeks prior to the MR scan * History of MI, stroke and/or poorly controlled hypertension.

Design outcomes

Primary

MeasureTime frameDescription
Aim 1At time of MRIThe difference between the deformation vector field derived from a given DIR algorithm (dDVF) and the known deformation vector field of the digital phantom (pDVF).

Secondary

MeasureTime frameDescription
Aim 2At time of MRIThe Relationship between the DVF errors and motion amplitude.
Aim 3At time of MRIThe relationship between the DVF and lung feature richness

Countries

United States

Contacts

Primary ContactRoselove Asare, BSRT
rnn3b@virginia.edu434-243-6074

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026