Optical Coherence Tomography (OCT) Intravascular Ultrasound (IVUS) Dual Imaging

Dual Imaging Using High-definition Intravascular Ultrasound and Optical Coherence Tomography to Guide Percutaneous Coronary Intervention

Status
Terminated
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02984891
Enrollment
7
Registered
2016-12-07
Start date
2016-10-06
Completion date
2018-06-27
Last updated
2021-03-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease (CAD)

Keywords

Intravascular ultrasound, Optical coherence tomography

Brief summary

Both intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are standardly used and have been extensively studied separately to guide percutaneous coronary intervention and improve long-term outcomes. In this study, the investigators aim to directly compare high-definition IVUS images to OCT in the same patients to determine the differences between each modality as they relate to imaging coronary pathology, with the goal of determining which modality is most appropriate in particular clinical scenarios.

Detailed description

Intravascular ultrasound (IVUS) is an imaging modality that uses ultrasound waves to allow for detailed evaluation of coronary atherosclerotic plaques and the vascular response to coronary interventional devices to guide stent placement during percutaneous coronary intervention. Current conventional IVUS catheters emit ultrasound waves ranging from 20-40 megahertz (mHz), and more recently released high-definition IVUS catheters emit sound waves at 60 mHz, allowing for better image quality, quantitative accuracy, and precision in measurements. Optical coherence tomography (OCT) is an alternative imaging modality used for similar purposes as IVUS, using a single optical fiber that emits infrared light to image the coronary artery. OCT uses light in the infrared spectrum with a central wavelength between 1,250 and 1,350 nm. Axial resolution with OCT is 10-20 microns, whereas it is typically 100-200 microns with IVUS. Thus, OCT allows for better image resolution, but this comes at the expense of tissue penetration.

Interventions

PROCEDUREOptical Coherence Tomography (OCT)

Procedure will be performed using the OCT Dragonfly catheter is a hydrophilic-coated catheter that uses infrared light with a central wavelength between 1,250 and 1,350 nm. Axial resolution with OCT is 10-20 microns, and maximum tissue penetration with OCT is approximately 1.5 mm-3 mm.

Procedure will be performed using the IVUS Kodama catheter is a hydrophilic-coated catheter that used high-fidelity ultrasound transmission to capture high-definition images of coronary artery anatomy. It uses ultrasound waves with a frequency of 40 or 60 MHz, as opposed to 20 MHz in conventional IVUS, to improve resolution while optimizing tissue penetration. It provides axial resolution of \< 40 microns and tissue penetration of 10 mm.

Sponsors

Columbia University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Undergone diagnostic coronary angiography * Evidence of coronary pathology that requires further imaging to guide treatment

Exclusion criteria

Significant renal insufficiency

Design outcomes

Primary

MeasureTime frame
Lumen areaUp to 1 hour
Luminal diameterUp to 1 hour

Countries

United States

Outcome results

None listed