Electrical Inhibition of Human Preterm Contractions

Electrical Inhibition (EI): A Preliminary Study to Prevent the Uterine Contractions of Human Preterm Labor and Preterm Birth

Status
Suspended
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02983240
Enrollment
110
Registered
2016-12-06
Start date
2017-03-01
Completion date
2026-01-21
Last updated
2024-12-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

PreTerm Birth, Preterm Labor, Preterm Labor With Delivery Nos

Brief summary

The purpose of this study is to explore a new method to stop preterm uterine contractions using an electrical device. The device, an electrical pacemaker for the uterus, has been approved by the Food and Drug Administration (FDA) for clinical research in pregnant women. The purpose of this study is to evaluate the feasibility and safety of the device. The investigators hypothesize that human preterm uterine contractions can be safely and objectively inhibited with a weak electrical current provided by an electrical inhibition (EI)/uterine pacemaker device, and that this effect relates to the timing and length of EI exposure.

Detailed description

The purpose of this study is to determine the effectiveness of a new method of preventing the human preterm uterine contractions of labor during electrical monitoring. The objective is to test a method for the inhibition of human preterm uterine contractions with an electrical pacemaker, electrical inhibition (EI). The study will investigate EI associated changes in preterm uterine contraction frequency as monitored by objective uterine tocodynamometry and adjunct electromyography (EMG) and electrohysterogram (EHG). The endpoint is the statistically significant EI induced decrease in the gold standard tocodynamometric monitored preterm uterine contraction frequency. The adjunct EMG and EHG monitoring provides valuable adjunct data about the electrical activity of the preterm uterine contractions and the effect of EI on this activity. The investigators hypothesize that human preterm uterine contractions can be safely and objectively inhibited with a weak electrical current provided by an electrical inhibition (EI)/uterine pacemaker device. This effect can be assessed by the use of a non-invasive tocodynamometer. It has been previously been shown that the frequency of contractions during preterm labor can be lowered by EI applied by the use of an intravaginal catheter carrying electrodes similar to a cardiac pacemaker (Karsdon et al). The investigators hypothesize that this effect relates to the timing and length of EI exposure.

Interventions

DEVICEElectrical Uterine Pacemaker

The catheter is placed under ultrasound guidance into the posterior vaginal fornix next to the external cervical os. The electrode connectors are attached to the EI device. Activating the EI device involves: 1) turning the current pulse duration rotary dial clockwise to the desired setting; this is an important setting and should be set at 20ms; 2) turning the current frequency rotary dial clockwise to the desired setting; 3) turn on the EI device on with the on/off toggle switch; 4) SLOWLY turning the current strength rotary dial clockwise to the desired setting, at this time the red light should be flashing. Usually 5-10mA of current is sufficient, but 20 mA is a maximum. Based on the tocometer recordings the least amount of EI current is given to inhibit the uterine contractions.

Sponsors

e-Bio Corp
Lead SponsorINDUSTRY

Study design

Allocation
NON_RANDOMIZED
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

* Wong-Baker pain score ≤ 6 * Pregnancy Depression Scale score \< 16 * Informed consent form signed and dated by patient * Be willing and able to comply with study requirements * Be between 18-50 years of age * Be between 23 to 36 5/7 weeks pregnant with a singleton gestation * Cervical dilation of ≤ 6 cm * A normal spontaneous vaginal delivery (NSVD) expected * Suspected to have preterm labor, as defined by the American College of Obstetricians and Gynecologists and the American Academy of Pediatrics, as follows.78 * Persistent uterine contractions (4 every 20 minutes, or 8 every 60 minutes) * And any one or more of the following: * Documented cervical change * 1 cm cervical dilatation and progressing -\> 80% cervical effacement * Be admitted to the maternity unit with the diagnosis of preterm labor or preterm contractions

Exclusion criteria

* Severe preeclampsia * Severe abruption placenta * Abnormal placentation (i.e. placenta previa) * Rupture of amniotic membranes * Active preterm labor with cervical dilation \> 6 cm * Exposed amniotic membranes * Vaginal bleeding \> 10 cc * Frank chorioamnionitis * Fetal death * Fetal anomaly incompatible with life * Severe fetal growth restriction (EFW \< 5%) * Uterine anomalies (i.e. bicornuate uterus, uterine didelphys) * Mature fetal lung studies * Maternal cardiac arrhythmias * HIV, Hepatitis C, Hepatitis B * History of herpes simplex virus (HSV) * A permanent cardiac pacemaker * A fetal cardiac arrhythmia * Contraindication for tocolysis e.g. premature rupture of the amniotic membranes allowing for ascending intrauterine infection with group B streptococcus or GBS (beta hemolytic streptococcus, S. agalactiae) or other micro-organisms. * IV or po narcotic pain medication \< 12 hours prior to admission (regional anesthesia, long acting oral maintenance opiates i.e. methadone, Suboxone, Subutex not included in

Design outcomes

Primary

MeasureTime frame
Uterine contraction frequency during labor as measured by external uterine tocodynamometric monitoringChange from 20, 40, and 80 minutes

Secondary

MeasureTime frame
FHR pattern as measured by the maternal-fetal monitorChange from 60 and 120 minutes
EMG monitoring as measured by LaborView DeviceChange from 60 and 120 minutes
EHG monitoring as measured by LaborView DeviceChange from 60 and 120 minutes
Maternal pain medication administrationBefore and after use of electrical uterine pacemaker, assessed up to 120 minutes
Maternal heart rateChange from 60 and 120 minutes
fECG monitoring as measured by LaborView DeviceChange from 60 and 120 minutes

Other

MeasureTime frame
Adverse eventsBefore and after use of electrical uterine pacemaker, assessed up to 120 minutes

Countries

United States

Outcome results

None listed