Skip to content

Airway Stents for Excessive Dynamic Airway Collapse

Airway Stents for Excessive Dynamic Airway Collapse: A Randomized Controlled Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02982876
Enrollment
50
Registered
2016-12-06
Start date
2016-12-31
Completion date
2024-12-31
Last updated
2025-07-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Excessive Dynamic Airway Collapse, Tracheobronchomalacia

Keywords

Silicone Airway stent, Metallic Airway stent

Brief summary

Airway stents are used as standard of care to identify which patients with excessive dynamic airway collapse will benefit from a definitive surgical treatment. However, the specific way in which these stents are effective has not been tested. The purpose of this research study is to determine the effectiveness of airway stents when used in the airways of patients with severe symptomatic excessive dynamic airway collapse compared to patients with severe symptomatic excessive dynamic airway collapse that do not receive airway stent.

Detailed description

Study Design This randomized controlled trial will be conducted at Beth Israel Deaconess Medical Center (BIDMC) in accordance with Good Clinical Practice Standards and under IRB supervision. We plan to enroll total of 48 patients with EDAC randomized by a computer generated system to either intervention group (airway stent) or medical management group. Description of the study Previous to appointment all patients will have Airway CT scan, 6 minute walk test and pulmonary function test as per protocol and standard of care. Enrollment Patients with severe EDAC who remain symptomatic despite optimal medical management will be informed about the trial and if interested will be recruited for the study. Operative Technique Patients in the treatment group (stent) will undergo bronchoscopy under light sedation and rigid bronchoscopy under general anesthesia. The treatment group will undergo a bronchial wash and placement of an airway stent.Patients assigned to the medical management group will not undergo bronchoscopy. Stents Based on the patient's airway anatomy an uncovered self-expanding metallic stent (Ultraflex™ Single-Use Tracheobronchial Stent System) or a silicone Y-stent(Endoxane, Novatech S.A., Aubagne-France or Channick Hood Laboratories, Pembroke, MA, 02359) will be used in the study. During Stent Trial After bronchoscopy, patients in the treatment group will receive a standardized medication regimen to include mucolytics, cough suppressors and expectorants in order to decrease the risk of potential complications following the procedure. Follow-up All participants will be scheduled for a follow-up visit in the following 14 days either after rigid bronchoscopy (treatment group) or after first visit (medical management group) with 6MWTs and PFTs. In this visit all patients will be asked to complete the SGRQ, CQLQ and mMRC questionnaires by the research team. All this data will be recorded in an encrypted database. Afterwards, the patients in the medical management arm will be offered a stent trial as part of standard of care. Stent removal The patients from the treatment arm will be scheduled for a rigid bronchoscopy, stent removal and bronchial lavage under anesthesia in the operating room.

Interventions

PROCEDUREDynamic Flexible Bronchoscopy

The bronchoscope will be introduced into the proximal trachea at the level of the cricoid. At that point, patients will be instructed to take a deep breath, hold it and then blow it out (forced expiratory maneuver). Maneuvers will be done at the following six sites: proximal trachea at the level of the cricoid; mid-trachea 5 cm proximal to the carina; distal trachea 2 cm proximal to the carina; right main stem bronchus at the right tracheobronchial angle; bronchus intermedius and left main bronchus at the left tracheobronchial angle

Under general anesthesia, a rigid bronchoscope (Bryan-Dumon Series II; Bryan Corporation; Woburn, MA) will be introduced, and respiration will be maintained through jet ventilation.

Silicone Y stent or uncovered self-expanding metallic stent will be placed in the standard fashion and good fit will be confirmed visually.

Sponsors

American Association of Broncology and Interventional Pulmonology
CollaboratorUNKNOWN
Curetbm.org Fundation
CollaboratorUNKNOWN
Hood Laboratories
CollaboratorUNKNOWN
Boston Medical products inc
CollaboratorUNKNOWN
Beth Israel Deaconess Medical Center
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient with sever symptomatic EDAC (collapse \>90% of the airway during exhalation at dynamic CT scan) * Age \> 18 years

Exclusion criteria

* Patients who have not been well managed from their respiratory comorbidities (asthma, COPD, obstructed sleep apnea, GERD, relapsing polychondritis) * Current respiratory infection * Resting bradycardia (\<50 beats/min), frequent multifocal PVCs, complex ventricular arrhythmia, sustained SVT * Dysrhythmia that might pose a risk during exercise or training * Any disease or condition that interferes with completion of initial or follow-up assessments

Design outcomes

Primary

MeasureTime frameDescription
St. George's Respiratory Questionnaire7-14 daysIndex designed to measure health status in patients with respiratory symptoms

Secondary

MeasureTime frameDescription
Cough Quality of life Questionnaire7-14 days
6 minute walk test7-14 days
FEV17-14 days
modified Medical Research Council scale of dyspnea7-14 daysShortness of breath scale
Self-reported symptoms7-14 daysdyspnea, inability to clear secretions, cough, recurrent infection and wheezing.
Complications7-14 daysAirway infections
Peak flow7-14 days

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026