Skip to content

Effect of Periprosthetic Fracture on Hip Function After Femoral Neck-preserving Total Hip Arthroplasty

Effect of Periprosthetic Fracture on Hip Function After Femoral Neck-preserving Total Hip Arthroplasty: a Prospective, Single-center, Self-controlled Trial With 2-year Follow-up

Status
UNKNOWN
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02981823
Enrollment
25
Registered
2016-12-05
Start date
2015-01-31
Completion date
2017-06-30
Last updated
2016-12-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Total Hip Arthroplasty

Brief summary

To provide information on reducing the incidence of periprosthetic fractures during hip replacement with the CFP prosthetic stem by analyzing the risk factors for periprosthetic fractures and their effects on hip functional recovery.

Detailed description

History and current related studies Periprosthetic fractures are one of the challenges for orthopedic surgeons that are more likely to appear during hip replacement with a cementless prosthesis. Hip replacement with a collum femoris preserving (CFP) prosthetic stem allows the preservation of the femoral neck and preserves bone tissues as much as possible for prosthetic revision in the future. However, the occurrence of periprosthetic fractures will result in a failure surgery. Existing evidence has shown that although hip replacement with the CFP prosthetic stem can reduce complications and pain, periprosthetic fractures that are more likely to occur during the surgery badly impact functional recovery in patients. Adverse events Adverse events which occurred during the follow-up, including hip pain, prosthetic loosening, spinal cord and nerve injuries, soft tissue infection and poor prosthetic position, were recorded. If severe adverse events occurred during the follow-up, their details including the date of occurrence, type of adverse events and measures taken were recorded and reported to the principal investigator and the institutional review board within 24 hours. Data collection, management, analysis, and open access Data collection Clinical data, including demographic data, disease diagnosis, accompanying diseases, allergic history (drug allergy) and adverse events, were collected and summarized using standardized case report forms. These data were processed using Epidata software and electronically input using double entry system. Data management After database confirmation, only the project manager was able to access the database. The locked data were unable to be altered and were preserved by the Third Hospital of Hebei Medical University. Data analysis All data were statistically analyzed by professional statisticians who were responsible for completing an outcome analysis report that was submitted to the project manager. An independent data monitoring committee was responsible for data monitoring and management throughout the entire trial to ensure scientific accuracy, stringency, authenticity, and integrity. Statistical analysis All data were statistically analyzed by statisticians using SPSS 21.0 software in line with the intention-to-treat principle. Normally distributed measurement data were expressed as means, standard deviations, minimums, and maximums, while non-normally distributed data were expressed as lower quartiles, medians, and upper quartiles. Wilcoxon matched paired test was used for comparative analysis of Harris hip scores and imaging parameters as determined before and 6, 12, 24 months after operation. Then, a multivariate logistic regression analysis was used to calculate the regression coefficient, OR, 95% CI with the Harris scale as the dependent variable for each imaging parameter which had significant difference. The statistical significance level was α = 0.05.

Interventions

PROCEDUREhip replacement

The patients undergo hip replacement with the collum femoris preserving stem suffered from periprosthetic fractures.

Sponsors

Hebei Medical University Third Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
No minimum to 50 Years
Healthy volunteers
No

Inclusion criteria

* Diagnostic and staging criteria in line with the Expert consensus on diagnosis and treatment of adult femoral head necrosis * Femoral head necrosis of Association Research Circulation Osseous (ARCO) stages III-IV * Unilateral femoral head necrosis * Age \< 50 years * Both genders

Exclusion criteria

* Advanced osteoarthritis * Secondary osteoarthritis due to acetabular dysplasia * Ankylosing spondylitis involving the hip joint * Rheumatoid arthritis * Inflammatory inflammation of the hip joint * Tumor lesions in the hip joint * Unable or refusal to sign the informed consent

Design outcomes

Primary

MeasureTime frameDescription
Harris hip scoresChanges of baseline and 6 months after operationTo evaluate the recovery of hip joint function. Harris hip scores have a range of 0-100 points: excellent ≥ 90 points, good 80-89 points, fair 70-79 points, and poor \<70 points. The higher score indicates the better function of the hip.

Secondary

MeasureTime frameDescription
X-ray imageChanges of baseline and month 6, month 12, month 24 after operationTo observe anteroposterior and frog-leg lateral X-ray films of the hip as well as full-length X-ray films of the bilateral lower extremities.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 28, 2026