Skip to content

CD180 Overexpression in Follicular Lymphoma

CD180 Overexpression in Follicular Lymphoma Is Restricted to the Lymph Node Compartment

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02978898
Enrollment
184
Registered
2016-12-01
Start date
2012-06-30
Completion date
2015-06-30
Last updated
2016-12-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Follicular Lymphoma

Keywords

Follicular Lymphoma, flow cytometry, CD180, Toll-like receptor, lymphoproliferative disease

Brief summary

Background:Altered Toll-like receptor (TLR) expression levels and/or mutations in its signaling pathway (such as MyD88 mutation) contribute to the pathogenesis of lymphoproliferative disorders (LPD). CD180 is an orphan member of the TLR family that modulates the signaling of several TLRs, but only limited studies have evaluated its expression by flow cytometry (FCM) in LPD. Methods: Using a multiparameter FCM approach, biologists have assessed CD180 mean fluorescence intensity (MFI) in lymph nodes (LNs) and peripheral blood (PB) samples obtained from patients with follicular lymphoma (FL; LN/PB, n=44/n=15), chronic lymphocytic leukemia (CLL, n=26/n=21), mantle cell lymphoma (MCL, n=13/n=17), and marginal zone lymphoma (MZL, n=16/n=12). Specimens from non-tumoral PB and LN (n=8/n=12) were used as controls.

Interventions

None listed

Sponsors

Hospices Civils de Lyon
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Samples from patients with: * LF: Follicular lymphoma * MCL: Mantle cell lymphoma * CLL/SLL: chronic lymphocytic leukemia/small lymphocytic leukemia * MZL : splenic marginal zone * Clt :control B-cells

Exclusion criteria

* Patient \<18 years old

Design outcomes

Primary

MeasureTime frameDescription
Immunophenotype Analysis by Flow Cytometry of lymph nodes samples at inclusionAt inclusion, day 0.Using a multiparameter FCM approach, biologists assessed the CD180 expression by our routine antigen panel in LN suspensions as well as in PB samples. Samples were analyzed on a BD FACSCanto II cytometer (BD FACS DIVA software; Becton Dickinson, San Jose, CA).
Immunophenotype Analysis by Flow Cytometry of peripheral blood samples at inclusionAt inclusion, day 0.Using a multiparameter FCM approach, biologists assessed the CD180 expression by our routine antigen panel in LN suspensions as well as in PB samples. Samples were analyzed on a BD FACSCanto II cytometer (BD FACS DIVA software; Becton Dickinson, San Jose, CA).

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026