Skip to content

HighLife™ Transcatheter Mitral Valve Replacement System Study

HighLife™ Transcatheter Mitral Valve Replacement System for Severe Mitral Regurgitation in Patients at High Surgical Risk

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02974881
Enrollment
5
Registered
2016-11-29
Start date
2017-07-20
Completion date
2024-01-16
Last updated
2024-10-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Mitral Valve Insufficiency, Mitral Valve Regurgitation

Brief summary

Multicenter feasibility study of the HighLife™ TMVR system.

Detailed description

This is an exploratory clinical study designed to evaluate the feasibility, safety and performance of the Highlife TMVR System in a population of patients with severe symptomatic mitral regurgitation, who are not suitable for surgical or approved percutaneous treatments according to the judgement of the Heart Team. The data gathered in this study will allow to evaluate the feasibility of mitral replacement using the HighLife™ TMVR system and characterize the safety and performance profile of the HighLife™ TMVR System. All patients will be followed periodically up to 12 months after the intervention and long term safety and performance will be collected annually up to 5 years.

Interventions

Minimally invasive transcatheter mitral valve implantation using the HighLife™ TMVR system

Sponsors

MedPass International
CollaboratorINDUSTRY
ICON plc
CollaboratorINDUSTRY
HighLife SAS
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age ≥ 18 years * Severe mitral regurgitation * New York Heart Association (NYHA) Functional Class II, III or ambulatory IV. * Patient is under maximally tolerated GDMT (incl. CRT) for at least 3 months * Multidisciplinary Heart Team consensus that the patient is inoperable or at high-risk for surgical repair/replacement due to significant co-morbid conditions * Multidisciplinary Heart Team consensus that the patient is not a suitable candidate for other approved percutaneous repair therapy due to anatomical or medical conditions * Patient meets the anatomical criteria for HighLife valve sizing as determined by CT and TEE Main

Exclusion criteria

* Mitral stenosis * Rheumatic valve disease * Severe calcifications of the mitral annulus and/or mitral leaflets * Prior surgical or interventional treatment of the mitral valve * Unsuitable anatomy for the transapical access * Unsuitable anatomy of the aorta and ilio-femoral vessels for the transfemoral access * Untreated clinically significant coronary artery disease requiring revascularization * LVEF \< 30% * LVEDD \> 70mm * Echocardiographic evidence of intracardiac mass, thrombus or vegetation * Hypertrophic Obstructive Cardiomyopathy (HOCM) * Any surgical or interventional procedure (including PCI) done in the past 30 days prior to procedure

Design outcomes

Primary

MeasureTime frameDescription
Freedom of major adverse eventsat 30 days post procedureincluding: * All-cause mortality * Myocardial infarction or coronary ischemia requiring PCI or CABG * Major stroke * Life-threatening bleeding (MVARC scale) * Major access and vascular complications * Stage 2 or 3 acute kidney injury (includes dialysis) * Any valve-related dysfunction, migration, thrombosis, or other complication requiring surgery or repeat intervention * Severe hypotension, heart failure or respiratory failure requiring intravenous pressors or invasive or mechanical heart failure treatments such as ultrafiltration or hemodynamic assist devices, including intra-aortic balloon pumps or left ventricular or biventricular assist devices, or prolonged intubation for ≥ 48H
Continued intended performance of the HighLife™ bioprosthesisat 30 days post proceduredefined as the reduction of mitral regurgitation (MR) to either optimal (0+ to trace) or acceptable (reduced by at least 1 grade from baseline with no more than 2+ MR) without significant mitral stenosis (post-procedure EOA ≥ 1.5 cm2 with a transmitral gradient \< 5mmHg) and with no greater than mild (1+) paravalvular MR (and without associated hemolysis)
Technical successimmediately after proceduredefined as alive patient at exit from procedure room, with all of the following: * Successful access, delivery and retrieval of the HighLife delivery systems * Deployment and correct positioning of the HighLife bioprosthesis * Freedom of additional emergency surgery or re-intervention related to the device or access procedure

Secondary

MeasureTime frameDescription
Procedure SuccessAt 30 days, 6 months and 12 months post procedureper MVARC definition
Quality of Life Improvement vs. BaselineAt 6 months and 12 monthsKansas City Cardiomyopathy Questionnaire
Hemodynamic Performance vs. BaselineAt 7 days, 30 days, at 6 months and 12 months and at 2, 3, 4 and 5 yearsEchocardiographic evaluation
Patient SuccessAt 30 days, 6 months and 12 months post procedureper MVARC definition
Functional Improvement vs. BaselineAt 30 days, 6 months and 12 monthsNew York Heart Association Class 6-Minute Walk Test
Device Success (per MVARC definitions)At 30 days, 6 months and 12 months post procedureper MVARC definition

Countries

France, Germany

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026