Skip to content

Quantification of Posterior Capsule Opacification in Pediatric Cataract

Quantification of Posterior Capsule Opacity With Software Analysis Comparing Intraocular Lenses Hydrophilic x Hydrophobic in Pediatric Cataracts

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02968290
Acronym
Cataract
Enrollment
30
Registered
2016-11-18
Start date
2016-05-01
Completion date
2017-11-30
Last updated
2018-01-09

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Posterior Capsule Opacification

Brief summary

The purpose of this study is to quantify the opacity of posterior capsule in pediatric cataract comparing two intraocular lens materials.

Detailed description

The eye exam at the first appointment will consist of anamnesis, external motor, evaluating strabismus and nystagmus, visual acuity with and without correction, biomicroscopy, fundoscopy, binocular ultrasound biometry, pachymetry and specular microscopy. The surgery will be performed by a single surgeon under general anesthesia. All participants will receive primary intraocular lens implantation as the randomization process, or hydrophobic acrylic material or hydrophilic acrylic. The implanted intraocular lens differ primarily in the material. The lens of hydrophobic acrylic materials (AcrySof SA60AT, Alcon Lab) single, folding part, material acrylate / methacrylate with UV protection AcrySof filter, optical diameter of 6.0 mm, total length of 13.0 mm, haptic angle of 0 degree with 360 degree double square edge, spherical convex earlier. The lens hydrophilic acrylic material (Akreos ADAPT, Bausch and Lomb) single, folding piece with optical diameter 6.00 mm and length de10.7 mm aspheric convex in anterior and posterior with absorbent UV, haptic angle 0 degree angulation . It has 4 attachment points (haptics) with 360 degree square double edge.

Interventions

PROCEDURECataract Surgery

Implant of intraocular lens hydrophobic or Implant of intraocular lens hydrophilic (Device)

DEVICEAlcon AcrySof SA60AT

Implant of intraocular lens hydrophobic

DEVICEBausch Lomb AkreosA

Implant of intraocular lens hydrophilic

Sponsors

University of Sao Paulo
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
QUADRUPLE (Subject, Caregiver, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
5 Years to 12 Years
Healthy volunteers
No

Inclusion criteria

* indication for cataract surgery

Exclusion criteria

* traumatic cataract * neurological diseases that do not allow the exams

Design outcomes

Primary

MeasureTime frameDescription
Opacification of posterior capsule measured by graduation through the software EPCO software360 days after cataract surgeryPhotodocumentation with camera coupled to slit lamp adapter with external coaxial illumination of a fiber optic cable to the camera. After, analysis of opacification of the posterior capsule through the Evaluation of Posterior Capsule opacification software (EPCO 2000). The EPCO (Evaluation of Posterior Capsule Opacification) software is commercially available and offers some free access. The individual PCO score is calculated by multiplying the density of the opacification by the fraction of capsule area involved behind the IOL optic. It graded the PCO as 0 (none), 1 (minimal), 2 (mild), 3 (moderate) or 4 (severe). EPCO is one of the most used software for this purpose.

Countries

Brazil

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026