Skip to content

Mandibular Advancement Bite Block Efficacy Observational Study

Mandibular Advancement Bite Block Efficacy Observational Study

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02964299
Enrollment
120
Registered
2016-11-16
Start date
2016-07-31
Completion date
2016-10-31
Last updated
2016-11-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Airway Obstruction

Keywords

Gastrointestinal endoscopy, Moderate sedation, Airway management

Brief summary

The purpose of this study is to compare the effect of mandibular advancement bite block to standard bite block for prevention of hypoxemia, intervention events and adverse effects during endoscopic examinations.

Detailed description

During endoscopic examinations, especially upper gastrointestinal, bile duct, or bronchoscopic examinations, the endoscope need to be placed through the mouth. A bite block is used to protect vulnerable endoscope and protect patient's teeth. During sedative endoscopic exams, respiratory depression, apnea or upper airway obstruction will occur under the influence of the sedative medications. Serious adverse events may occur such as hypoxemia. A nasal airway, Larson's maneuver, jaw thrust or chin lift may be needed to open airways. Mandibular advancement devices has been widely used in treating obstructive sleep apnea. A modified bite block that provides mandibular advancement could provide entry inlet of endoscope as well as provide mandibular advancement to provide patent airway during sedative endoscopy. In this study, we group the patients into test group using mandibular advancement bite block and a control group using standard bite block. After anesthetic induction, gastric endoscopy was performed. Degree of upper airway obstruction will be evaluated and recorded. Differences between the two groups will be evaluated.

Interventions

DEVICEMandibular advancement bite block

Mandibular advancement bite block that provides mandibular advancement by 3 mm, 6 mm, or 9 mm from neutral position

Sponsors

Taipei Veterans General Hospital, Taiwan
Lead SponsorOTHER_GOV

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
20 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

* American Society of Anesthesiologist class I or II * Patients undergoing routine upper gastrointestinal endoscopy under sedation

Exclusion criteria

* Baseline oxygen saturation \< 90% * Known difficult airway * Oral or facial surgery history * BMI \> 35 * patients with gastroparesis or gastrointestinal bleeding * anticipated exam time \> 30 minutes

Design outcomes

Primary

MeasureTime frameDescription
Area under curve of 95% oxygen desaturationup to 30 minutesFrom start of sedation drug administration to end of endoscopic examination with the endoscope withdrawal from patient's mouth, peripheral oxygen saturation recorded. Area under curve of 95% oxygen desaturation is calculated by (95-saturation) x time.

Secondary

MeasureTime frameDescription
number of rescue interventions: chin lift, jaw thrust, insertion of nasal airway or mask-bag ventilationup to 30 minutesFrom start of sedation drug administration to end of endoscopic examination with the endoscope withdrawal from patient's mouth, number of events such as chin lift, jaw thrust, insertion of nasal airway, or mask-bag ventilation recorded.
Adverse events: partial or complete airway obstruction, or apneaup to 30 minutesFrom start of sedation drug administration to end of endoscopic examination with the endoscope withdrawal from patient's mouth, number of events such as snoring, stridor, apnea, airway obstruction or loss of end tidal carbon dioxide waveform recorded.

Countries

Taiwan

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026