Skip to content

Insulin Effects on Cardiac Function in Patients With Diabetes Mellitus

Acute Insulin Effects on Cardiac Function in Patients With Diabetes Mellitus

Status
Completed
Phases
Phase 4
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02962921
Enrollment
6
Registered
2016-11-15
Start date
2003-02-28
Completion date
2004-11-30
Last updated
2016-11-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Diabetes Mellitus, Ventricular Dysfunction

Brief summary

Our investigation studies the role of acute insulin administration on the diabetic heart, its corresponding effective blood-insulin level and the time-course applicability of insulin in a routine clinical setting. A case series of six male (48.1 ± 4.9 y/o) patients with controlled diabetes (HbA1c of 6.6 ± 0.3%, disease duration of 14.4 ± 6.7 yr). Each subject was evaluated for glucose homeostatic, hemodynamic and echocardiographic systolic and diastolic parameters at baseline and following two successive insulin-load steps of a euglycemic hyperinsulinemic clamp study, each 2 h in duration. Results are presented as a mean ± SEM and analysed using the student's t-test.

Detailed description

Patients: Six male diabetic (five type 2 and one type 1) patients, 30-65 year old, with an established diagnosis of diabetes mellitus for ≥2 years, who were free of significant valvular heart disease, atrial arrhythmia or cardiac pacing comprised the study population. Patients' characteristics are summarized in table 1. Each patient served as his or her own control. The study protocol was approved by the ethics committee at Rambam Medical Center, Haifa, Israel. Prior to the study, patients gave written informed consent after receiving a detailed explanation as to the purpose of the study, the technique, its side effects and the study protocol. Patients were studied within a clinical research facility at the Rambam Medical Center, Haifa, Israel. Baseline evaluation was conducted at 8:00 am after 12 h of fasting, followed by two hyperinsulinemic euglycemic clamp (EHC) steps (2 h each step); The following vital signs were monitored during the study protocol: manual heart rate, systolic blood pressure (SBP), diastolic blood pressure (DBP) and baseline 12-lead electrocardiogram (ECG) recording. Glucose consumption rates against changing insulin levels were measured by the EHC technique. Cardiac function parameters were measured in the last 10 min of each step by tissue Doppler echocardiography. Results are presented as a mean ± SEM. Clamp technique: Each patient underwent an EHC study according to the protocol described previously, and implemented in our institute. Baseline measurements of blood insulin and glucose levels were collected. Thereafter, two insulin loads were initiated. The blood glucose level was kept near euglycemia (90 ± 5 mg/dl) throughout 2 h period of each insulin load step. Intravenous (iv) insulin loads were administered by 1- and 10-mU/kg·min at steps 1 and 2 of insulin loading (Lispro Insulin, Eli Lilly, France), respectively. Dexstrose in water 50% (DW50) was infused at variable infusion rates, titrated to maintain euglycemia. Concomitant saline 0.45% was used to dilute the DW50 in order to prevent hypertonicity-induced irritation of the cannuled vein. During the baseline period, saline 0.45% infusion rates were 0.75 ml/min to keep the iv cannule open. Every patient was given a chance to urinate before step 2. Glucose and insulin homeostatic parameters of the study group were compared to those of healthy controls we studied earlier. Cardiac function assessment: Transthoracic echocardiography was performed by a qualified echocardiographer using a General Electric Vivid 3 machine (Tirat HaCarmel, Israel). Parameters were assessed as the mean of three consecutive heart beats. Systolic echocardiographic parameters: LV fractional shortening (LVFS) derived from end diastolic and end systolic LV dimensions; LV ejection fraction (LVEF) derived from end diastolic and end systolic LV volumes. Diastolic echocardiographic parameters: 1. Mitral valve diastolic flow parameters by pulse wave Doppler: E wave, represents early diastolic filling; A wave, represents late diastolic filling concomitant with the atrial kick, E/A ratio and E wave deceleration time (DT). 2. Tissue Doppler-derived velocities of the mitral annulus: E' represents early diastolic velocity synchronous to the mitral inflow E wave, measured close to the interventricular septum (E' medial) and lateral wall (E' lateral); E' mean, derived from E' lateral and E' medial. A' represents late diastolic velocity to the synchronous mitral inflow A wave, measured close to the septum (A' medial) and lateral wall (A' lateral). A' mean is derived from A' lat. and A' med. A' reflects mitral annulus movement during atrial contraction. The E to E' ratio represents diastolic LV compliance. Results are presented as mean ± SEM and analyzed using the student's t-test. Statistical significance considered when p value less than 0.05.

Interventions

DRUGInsulin LISPRO intravenous loading

intravenous infusion of insulin Lispro.

Sponsors

Rambam Health Care Campus
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
30 Years to 65 Years
Healthy volunteers
No

Inclusion criteria

* Diabetes mellitus duration of 2 years and over.

Exclusion criteria

* Previous cardiac disease: valvular, Pacing, Arrhythmias, Primary Cardiomyopathy.

Design outcomes

Primary

MeasureTime frame
Left ventricle ejection fraction (%)1 year

Secondary

MeasureTime frameDescription
Time needed to exert insulin effect on myocardial function (hour)1 yearDescribe the shortest time required for insulin to change myocardial function.

Other

MeasureTime frame
E wave (centimeter per second)1 year
A wave (centimeter per second)1 year
Blood insulin levels (μU/ml: micro international unit per milliliter)1 year
E' (centimeters)1 year
A' (centimeters)1 year
E deceleration time (seconds)1 year
Left ventricle fractioning shortening (%)1 year

Countries

Israel

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 18, 2026