Skip to content

Pivotal Study of the Rx Al-Sense Liner for Amniotic Fluid Leakage Screening

Pivotal Study of the Rx Al-Sense Liner for Amniotic Fluid Leakage Screening in the Second and Third Trimesters of Pregnancy

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02959268
Acronym
PRALS
Enrollment
250
Registered
2016-11-09
Start date
2016-11-30
Completion date
2017-10-31
Last updated
2019-10-31

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Amniotic Problems

Brief summary

This is a Prospective open-label, comparative pivotal study with comparison of self-assessments with blinded investigator assessments. Pregnant women attending the labor and delivery unit of the hospital or emergency clinic and reporting unidentified wetness (undetermined whether this is amniotic fluid leakage or urinary incontinence) will be enrolled in this study. After informed consent is obtained, each subject will be given a single AL-SENSE to use up to 12 hours or until the perception of wetness. Product Usage After usage, the subject will read and record any occurrence of color change of the AL-SENSE 10 minutes after the liner removal and to mark if it changes color to blue or to green or not on the designated form. The subjects will fill out the questionnaire regarding the product usage experience and the liner color reading with no help from the investigator, to validate IFU reading comprehension. A blinded clinician will perform a standard clinical diagnosis (clinical assessment). The standard clinical diagnostic methods will include the following tests: (1) Pooling test, (2) Ferning test, (3) pH test by pH paper. A positive Pooling test and/or positive results in both the pH test and the Ferning test will be defined as a positive clinical test result.

Detailed description

This study is designed to demonstrate that the performance of the AL-SENSE developed by Common Sense Ltd. is safe and effective and can be used to indicate if the patient may be experiencing an amniotic fluid leakage . The AL-SENSE is an extended shelf-life product that is technically simple, fast to react, visually readable, and therefore enables women to test the cause of any unidentified wetness, before confirmation by a physician. Principles of operation: Vaginal fluids are discharged over time and collected on the non-intrusive panty liner. If the user observes a blue or green stain, the result of the test is positive. The AL-SENSE polymer matrix is stained by blue or green color on a pale yellow background when the pH level of the fluid in contact with it is greater than the cutoff value. The AL-SENSE will indicate that the pH level is elevated when the level is equal or greater than 6.5. This choice of 6.5 units as the cutoff level will limit the cases of false positive and will reduce unnecessary alarm. Summary of Study Design Design: Prospective open-label, comparative pivotal study with comparison of self-assessments with blinded investigator assessments. Patient Population: Pregnant women, ages 18 and above. Baseline/ Screening Subjects attending the labor and delivery unit of the hospital or emergency clinic and reporting unidentified wetness (undetermined whether this is amniotic fluid leakage or urinary incontinence) will be enrolled in this study. After informed consent is obtained, each subject will be given a single AL-SENSE to use up to 12 hours or until the perception of wetness. The clinician will explain the proper use and handling of the AL-SENSE and how to read the result. The participants will be provided with instructions for use and also directed to read the Instructions For Use (IFU) prior to applying the AL-SENSE pad. Product Usage After usage, the subject will read and record any occurrence of color change of the AL-SENSE 10 minutes after the liner removal . The subjects will fill out the questionnaire regarding the product usage experience and the liner color reading with no help from the investigator, to validate IFU reading comprehension. Clinical Diagnosis A blinded clinician will perform a standard clinical diagnosis (clinical assessment), and record the results on a worksheet to be included in the case report form. The standard clinical diagnostic methods will include the following tests: (1) Pooling test, (2) Ferning test, (3) pH test by pH paper.

Interventions

DEVICEAl-Sense

Liner for diagnosis of amniotic fluid leakage verified by standard clinical diagnostic tests

Sponsors

Common Sense
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
FEMALE
Age
18 Years to 50 Years
Healthy volunteers
Yes

Inclusion criteria

Screening/ Baseline inclusion criteria for subject participation in the study at baseline assessment are pregnant women age 18 and above who have completed minimum 16 weeks of pregnancy are eligible for the study. Subject attending the labor and delivery unit of the hospital or emergency clinic or outpatient clinic and reporting a feeling of vaginal wetness feeling (undetermined whether this is amniotic fluid leakage or urinary incontinence)

Design outcomes

Primary

MeasureTime frameDescription
Color change of pantyliner surface compared to standard clinical diagnosis10 minutesColor change

Secondary

MeasureTime frameDescription
Questionnaire to assess subject comprehension of usage criteria and subjective experience15 minutesSelf-report of product usage experience and correct usage according to instructions for use
Subject vs. Clinician reading of liner color changeup to 48 hourscompare subject and clinician readings

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026