Skip to content

Pressure Ulcer Monitoring Platform (PUMP)

Pressure Ulcer Monitoring Platform (PUMP): A Device to Monitor Patient Positioning

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02952664
Acronym
PUMP
Enrollment
12
Registered
2016-11-02
Start date
2017-01-31
Completion date
2017-07-06
Last updated
2017-07-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pressure Ulcer

Brief summary

This study will employ two monitoring device prototypes. The devices are sensors containing accelerometers and gyroscope. The raw output data will be analyzed to determine when patients are moved or are repositioned in their beds. The data is captured within a modem which will correlate these movements with video recordings for interpretation by the research team. One sensor is wearable on the patient gown or sleepwear, and the other is placed underneath the frame of the hospital bed. The investigators propose a non-blinded trial with n=10 where all subjects will undergo the two devices. A video camera will be placed in each subject room for recording the repositioning events to correlate the monitor signals with the actual subject repositioning captured by the video. The goal of the trial is to validate the ability of each of the sensor prototypes to accurately detect when subjects are turned, in order to reduce stationary positioning which contributes to the incidence of pressure ulcers and to improve compliance with patient repositioning trials.

Detailed description

The investigators propose a non-blinded trial with n=10 where all subjects will undergo the two devices. A video camera will be placed in each subject room for recording the repositioning events to correlate the monitor signals with the actual subject repositioning captured by the video. The goal of the trial is to validate the ability of each of the sensor prototypes to accurately detect when subjects are turned, in order to reduce stationary positioning which contributes to the incidence of pressure ulcers and to improve compliance with patient repositioning trials. The repositioning events recorded by the sensor devices will be automatically uploaded and abstracted by the research team, along with the events captured by the simultaneous video recording of patient repositioning.

Interventions

BEHAVIORALPUMP Monitoring

A video camera will be placed in each subject room for recording the repositioning events to correlate the monitor signals with the actual subject repositioning captured by the video.

Sponsors

University of Pittsburgh
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
PREVENTION
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Subject is over 18 years of age * Subject is immobile and/or unable to independently re-position self

Exclusion criteria

* Subject is under the age of 18 years * Subject is able to independently re-position self

Design outcomes

Primary

MeasureTime frameDescription
Comparison of sensor output with video-recorded data10 hours of monitoringThe dependent variables evaluated in this study are the measured outcomes as recorded by the devices and the signals collected from the accelerometer and gyroscope within said devices; the independent variable to be evaluated in this study is patient movement.

Countries

United States

Outcome results

None listed