Skip to content

Improvement of Tinnitus After Oral Zinc on Patients With Noise-induced Hearing Loss

Evaluation of the Effects of Zinc in the Management on Tinnitus Patients With Noise Induced Hearing Loss

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02951715
Enrollment
20
Registered
2016-11-01
Start date
2013-12-31
Completion date
2014-12-31
Last updated
2016-11-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hearing Loss, Noise-Induced, Tinnitus, Noise Induced, Zinc Deficiency

Brief summary

Twenty patients with tinnitus and a typical noise-induced hearing loss (NIHL) audiogram were included. Each subject underwent an otoscopic examination, distortion product otoacoustic emissions, tinnitus-match testing, Tinnitus Handicap Inventory (THI) and serum zinc level analyses. After 2 months of treatment with zinc, all tests were repeated.

Detailed description

This study enrolled patients who visited our out-patient department with the primary complaint of tinnitus. A full medical history assessment was performed, and each patient underwent an otoscopic examination, a basic audiologic evaluation. We selected the patients whose audiogram data met the inclusion criteria for NIHL: 1) bilateral typical NIHL audiogram and type A tympanogram; 2) hearing threshold above 4 kilohertz (kHz) was greater than 25 dB hearing level (HL); 3) audiogram showed the characteristic 4 kHz or 6 kHz notch (average hearing threshold was 10 dB HL higher than the baseline); 4) up-turn phenomenon appeared above 6 kHz or 8 kHz, and 5) symmetrical hearing loss threshold over bilateral ears and the disparity was less than 10 dB HL. Patients with other otologic diseases were excluded. A full medical history assessment was performed, and each patient completed the NIHL questionnaire (Supplementary S1), audiogram, tympanogram, speech discrimination test, distortion product otoacoustic emissions (DPOAE) testing, pitch and loudness match of the tinnitus, Tinnitus Handicap Inventory (THI) and serum zinc level analyses. All tests were repeated after 2 months of treatment with zinc gluconate (Zinga 78 mg, 10 mg elemental zinc), two tablets twice per day (40 mg per day).

Interventions

2 months of treatment with zinc gluconate (Zinga 78 mg, 10 mg elemental zinc), two tablets twice per day (40 mg per day)

Sponsors

Chang Gung University
CollaboratorOTHER
Chang Gung Memorial Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
20 Years to 80 Years
Healthy volunteers
Yes

Inclusion criteria

* 1\) bilateral typical NIHL audiogram and type A tympanogram; 2) hearing threshold above 4k Hz was greater than 25 dB HL; 3) audiogram showed the characteristic 4 kHz or 6 kHz notch (average hearing threshold was 10 dB HL higher than the baseline); 4) up-turn phenomenon appeared above 6 kHz or 8 kHz, and 5) symmetrical hearing loss threshold over bilateral ears and the disparity was less than 10 dB HL. Patients with other otologic diseases were excluded.

Exclusion criteria

* Patients with pregnancy, psychologic diseases and other otologic diseases were excluded.

Design outcomes

Primary

MeasureTime frameDescription
Tinnitus Handicap Inventory (THI)2 monthsWe used the Mandarin-Chinese version of THI questionnaire to evaluate subjective tinnitus19. The severity of subjective tinnitus was divided into five subgroups including very mild (0\ 16 points), mild (18\ 36 points), moderate (38\ 56 points), severe (58\ 76 points), and very severe (78\ 100 points).
Serum zinc level2 months

Secondary

MeasureTime frameDescription
Distortion product otoacoustic emissions (DPOAE)2 monthsThe measurement of DPOAE used two pure-tone stimuli at frequencies of 65 dB sound pressure level (SPL) (f1) and 55 dB SPL (f2) with an f2/f1 (frequency) ratio of 1.22. The geometric mean frequencies (GM Hz) ranged from 5 to 10 kHz. The most robust DPOAE occurs at the frequency determined by the equation 2f1-f2 (recorded as DP Hz), whereas the actual cochlear frequency region assessed with DPOAE is between these two frequencies, probably close to the f2 stimulus. The stimulus intensity was defined as positive when all frequencies of 2f1-f2 tested 6 dB SPL greater than the noise floors (NF).
Pitch of tinnitus2 monthsWhen the matching procedure was first used, the level was initially set at 5 dB above the highest measured audiometric threshold (at any frequency), and the patient reported the audiometric frequency that gave the closest match to the pitch of their tinnitus, repeated three times.
Pure tone audiometry (PTA)2 monthsTests were conducted in a sound-treated booth (background noise level less than 30 dB A) equipped with a two-channel clinical audiometer (GSI 61).
Tinnitus loudness level (dB SL)2 monthsThe tinnitus loudness level (dB SL) was calculated as the intensity level minus the baseline-hearing threshold
Loudness of tinnitus2 monthsThen the level was adjusted in 2-dB steps until the patient indicated that the tone matched the loudness of their tinnitus, repeated three times.
Speech discrimination2 monthsTests were conducted in a sound-treated booth (background noise level less than 30 dB A) equipped with a two-channel clinical audiometer (GSI 61).

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026