Skip to content

Clinical Impact of Non-invasive Hemodynamic Monitoring

Evaluation of Clinical Impact of Non-Invasive Hemodynamic Monitoring to Optimize Preventative Care of Heart Failure Patients

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT02950597
Enrollment
70
Registered
2016-11-01
Start date
2016-09-19
Completion date
2019-11-19
Last updated
2020-07-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Failure

Brief summary

Study Details What is the study design? (eg, randomized, double-blind) Observational Prospective Study What are the overall objectives of the study? This project is designed to assess the feasibility of using a non-invasive hemodynamic monitoring device in heart failure outpatient clinics. There will be no alteration to patient management for this study. Rather this study seeks to assess the utility of the device by evaluating for the parameters obtained from the device to hospital admission. How your research will contribute to the advancement of scientific knowledge? ☒This study will confirm/strengthen existing knowledge. ☒This study will test a completely novel hypothesis. ☒This study will explore novel endpoints. ☐Other \[please describe\]:

Detailed description

B. BACKGROUND: Nearly five million Americans experience heart failure (HF) and greater than 250,000 die annually. 1 The prevalence has continued to increase with the aging of the US population and HF is now the leading cause of hospitalization among adults \>65 in the United states. Despite remarkable improvements in medical therapy, the prognosis of patients with myocardial failure remains poor, with almost 20% of patients dying within 1 year of initial diagnosis and \> 80% 8-year mortality. 2 In addition patients who are admitted to the hospital for heart failure have over a 50% readmission rate within six months of discharge. 3,4 These patients require routine clinical care and often require diagnostic and therapeutic procedures. This project seeks to assess if the use of hemodynamic (HD) monitoring technologies (ClearSight/Nexfin) that are currently used in the intraoperative and critical care settings can provide utility by demonstrating associations between alterations in a patients HD values to the likelihood of hospital admission. The non-invasive HD device utilized (Nexfin, Edwards Lifesciences, Irvine, CA) provided flow-guided cardiovascular parameters that were captured for each clinic visit for up to 24 months. Analysis was performed between the most recent prior clinic visits for patients who were hospitalized for HF exacerbation to those who were not hospitalized. HD data was not used to guide clinical care. A Cox hazard model using a log transformation of HD variables as the covariates, was applied to describe hospital admission.

Interventions

DEVICEObservational Study to Evaluate Utility of Non-invasive Hemodynamic Monitoring

Sponsors

Loma Linda University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients seen in Loma Linda heart failure clinics classified as New York Heart Association (NYHA) Functional Classification of 3 or greater.

Exclusion criteria

* Age \< 18 years of age, * pregnancy, * known severe peripheral artery disease, * poor perfusion to fingers (as defined as a perfusion index less than 0.5%- www.Masimo.com), * history of Raynaud's, * refusal to provide written consent.

Design outcomes

Primary

MeasureTime frame
associations between alteration of HD values to hospital admission24 months

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026