I-Gel vs Ambu Laryngeal Mask Airways in Infants and Children Undergoing Surgical Procedures

I-Gel vs Ambu Laryngeal Mask Airways in Infants and Children Undergoing Surgical Procedures: A Randomized Clinical Trial

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT02938039
Enrollment
112
Registered
2016-10-19
Start date
2015-05-31
Completion date
2016-10-31
Last updated
2016-10-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Laryngeal Masks

Keywords

laryngeal airways, infants, neonates, children, anesthetized

Brief summary

This study will guide the anesthetists regarding the appropriate selection of the LMA in neonatal age group based on scientific basis. This study will add up to existing literature about the safety of LMA usage in neonates and infants. Furthermore it may shed some light on which LMA type will be more feasible and effective for neonatal/ infants usage.

Detailed description

Laryngeal mask airways (LMAs) are in practice of anesthesia since early 1980s. Pediatric and neonatal patients (including ex-premature) have also been benefited by the use of LMA. There are many advantages of LMA over endotracheal tube (ETT) in pediatric patients like ease of insertion, securing airway rapidly, avoidance of muscle relaxants, reduced incidence of sore throat, post operative hoarseness and coughing at the time of extubation, greater hemodynamic and intraocular pressure (IOP) stability. LMA has been recognized internationally in control of airway in difficult and failed intubation. There are different types of pediatric LMAs available e.g. I-gel, ProSeal, LMA supreme, LMA classic, LMA unique, LarySeal and Ambu. These devices differ morphologically from each other (silicone, polyvinyl chloride or soft gel). There have been several randomized controlled studies comparing different LMAs in adults, however, the literature is sparse in which such comparison has been made in patients with weight 10 kg or below.

Interventions

DEVICEAmbu LMA

Ambu Laryngeal Mask Airways

DEVICEI-Gel LMA

I-Gel Laryngeal Mask Airways

Sponsors

King Saud University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
1 Days to 14 Years
Healthy volunteers
No

Inclusion criteria

* Elective surgical procedures * No muscle relaxant agents * No other comorbidities

Exclusion criteria

* Emergency surgical procedures * Full stomach * Subjects with upper respiratory tract infection * Failed caudal block

Design outcomes

Primary

MeasureTime frameDescription
Airway Leak Pressure17 monthsIt will be measured in mmHg unit and the expiratory valve will be closed with a fresh gas flow of 3 l.min-1 until an audible leak is heard, airway pressure will not be allowed to exceed 25 cmH2O), and then released completely

Secondary

MeasureTime frameDescription
Ease of insertion18 monthsThe ease of placement of LMA will be assessed using a subjective scale of 1-4 (1 = no resistance and no maneuvers, 2 = mild resistance and one maneuver, 3 = moderate resistance and more than one maneuver, 4 = inability to place the device)
Success at first attempt18 monthsThe insertion will be labelled as a 'failure' if the device could not be successfully placed within two attempts or lacked a square-wave capnograph tracing, or if there was airway obstruction (e.g. oxygen desaturation \< 90%, abnormal thoraco-abdominal movements, or obstructive noises or no rise of chest at all), inadequate ventilation (an inability to deliver a minimum of 7 ml.kg-1 tidal volumes, or an audible leak)
Effective airway time18 monthsIt will be measured in seconds unit , and The time for successful insertion will be measured from the moment the facemask will be removed until attainment of first capnography upstroke after insertion
Gastric Insufflation18 monthsIt is a Yes or No outcome measure and auscultation with a stethoscope will be performed over the epigastrium during leak pressure testing to detect the occurrence of gastric insufflation
Manipulation of the Device18 monthsthe number and type of airway manipulations (gentle advancement, withdrawal of device without removal, jaw thrust, or neck extension) required to maintain airway patency during the case will be recorded
Oxygen Desaturation less than 90%18 monthsIt is a Yes or No outcome measure and it will be measured using the oxygen saturation monitor placed on finger and the reading will be detected on the capnography